BA

BA
1 / 45 PagesView full catalog

BA

Product catalog summary
Overview of Valve Bank Type BA
The Valve Bank Type BA is designed for operating independent consumers by combining different valves. It features flexible assembly options with several valve sections based on sub-plates, allowing for compact hydraulic manifold configurations. It can be flange mounted on hydraulic power packs, with intermediate plates enabling additional functions like pressure reducing and load-holding valves.

Available Versions
The document details ordering examples and descriptions of components such as basic types, connection blocks, valve sections, and intermediate plates, each specified with flow rate and pressure parameters.

Specifications
Specifications include pressure ranges, flow rates, and coding for different models. It details materials, installation positions, and compatible hydraulic fluids, along with operating pressure and flow rate limits.

Dimensions
Dimensions for connection blocks, valve sections, sub-plates, reactive plates, intermediate plates, and end plates are provided.

Installation, Operation, and Maintenance
This section covers intended use, assembly, operating instructions, and maintenance guidelines, emphasizing adherence to specifications and instructions for throttle screw adjustments.

Standards and Recommendations
References to DIN and ISO standards for hydraulic fluids and cleanliness levels are included. Recommendations highlight the need for specialist personnel for assembly and operation.

Key Components and Features
Descriptions of components such as valve banks, end plates, and intermediate plates are provided, along with coding and connection details. Information on solenoid voltage, connectors, and pressure-limiting valves is included.

Diagrams and Tables
Tables and diagrams illustrate coding, connection patterns, and component dimensions, aiding in understanding system configuration and installation.

Critical Information
Key parameters such as maximum operating pressures, flow rates, and temperature ranges are highlighted. Warnings against exceeding throttle screw adjustments are provided to prevent system damage.

Hydraulic Fluid Purity and Filtering
Emphasizes the importance of filtering new hydraulic fluid to meet purity standards and advises against mixing fluids from different manufacturers.

Maintenance Information
Recommends annual visual inspections for damage and leakages, with instructions to shut down and repair the system if issues are found.

Accessories and Spare Parts
Information on ordering spare parts through HAWE Hydraulik's contact map is provided, along with available types and sizes of discs and spacer sleeves.

Additional Information
Lists various compact hydraulic power pack types and valve banks with codes for reference, and provides contact information for HAWE Hydraulik SE for further inquiries.
See more

Catalog excerpts

BA-1

Valve bank (nominal size 6) type BA Product documentation Operating pressure pmax: Flow rate Qmax:

 Open the catalog to page 1
BA-2

© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide individual...

 Open the catalog to page 2
BA-4

Overview of valve bank (nominal size 6) type BA A valve bank combines different valves for operating independent consumers. The directional valve bank type BA consists of several valve sections, which are based on sub-plates. They can be used to exibly assemble compact hydraulic manifolds. The type BA valve bank can be ange mounted directly on the hydraulic power packs. The intermediate plates type NZP enable additional functions and contain, for example, pressure reducing valves, shock valves, load-holding valves, etc. An intermediate plate can be inserted between the sub-plate and the valve....

 Open the catalog to page 4
BA-5

Available versions -G 24 2.6 "Solenoid voltage and connector" 2.5 "End plates" 2.3.2 "Sub-plates" 2.3 "Valve sections" 2.4 "Intermediate plates" 2.2 "Connection block" 2.1 "Basic type and size" 2.1 Basic type and size Type Flow rate Qmax (lpm) for directional valves NG 6 (ISO 4401-03, CETOP 03) and others Return line pressure pmax (bar) DAMAGE Observe the specifications of the attached directional valves and upstream hydraulic power packs. 2.2 Connection block Coding Without coding Direct mounting on connection blocks of type AB (D 6905 AB) for combination with compact hydraulic power packs of...

 Open the catalog to page 5
BA-6

2.3 Valve sections 2.3.1 Directional valves Coding Flow rate Qmax (lpm) 3/2, 3/3, 4/2 and 4/3 directional spool valve with additional options (pressure monitoring, restrictors and restrictor check valves in the ports) 3/3 and 4/3 directional spool valve Clamping module (combination of 4/2 or 4/3 directional spool 25 valve, pressure reducing valve and tracked pressure switch) 2/2, 3/2 and 4/3 directional seated valves Directional valves NG 6 Can be combined with intermediate plates type NZP to D 7788 Z NSWP 2 NOTE 20 In contrast to the designation of a single valve to D 7765 N, a coding for the...

 Open the catalog to page 6
BA-7

Circuit examples for directional valves sub-plates NSWP 2 G/M/R/ABV1.0 BBV1.5/70/S/3

 Open the catalog to page 7
BA-8

Series (See coding for double sub-plates for two individual sections /10) Position of the consumer ports on opposite side additional, releasable check valve in A (Type CRH 1 to D 7712) with additional throttle in T (Type Q 30 to D 7730) additional pressure gauge connections MA and MB (See coding for double sub-plates for two individual sections /10) additional drain port for the combination with the intermediate plate NZP 16 SDM 2L to D 7788 Z G 3/8 NOTE following valve sections must also have sub-plate coding /4. For the end plate, coding -1L to Chapter 2.5, "End plates", is selected. /5 doubly...

 Open the catalog to page 8
BA-10

2.4 Intermediate plates Coding Pressure reducing valve for pressure reduction in the downstream P channel see Chapter 2.4.1, "Pressure reducing valves in the P channel" Intermediate plate as spacer (50 mm) without internal function Intermediate plate with additional P and R ports ZPL/V... ZPL/S... Intermediate plate for a 2nd Speed see Chapter 2.4.2, "Intermediate plate for a 2nd Speed" ZPL/MVE 6/.. ZPL/MVE 6/../R ZPL/MVEX 6/.. ZPL/MVEX 6/../R Intermediate plate with pressure-limiting valve, drain valve and accumulator port Intermediate plate with proportional pressure-limiting valve for a second...

 Open the catalog to page 10
BA-11

2.4.1 Pressure reducing valves in the P channel Ordering example BA 2 A5 Check valve Pressure setting (bar) Pressure adjustment Pressure range Pressure reducing valve Pressure reducing valve Coding Pressure reducing valve type CDK to D 7745 Pressure reducing valve type CDK to D 7745, valve turned through 90° Pressure reducing valve type CDK to D 7745, with direct accumulator port Pressure reducing valve type CLK to D 7745 L, with overpressure function Without pressure reducing valve with tapped plug prepared for retrotting

 Open the catalog to page 11
BA-12

Check valve in P coding R Drain valve Check valve in P coding R Drain valve Check valve in P coding R Drain valve Coding -CZX, CZAX, CZDX, LZX (Example illustration as type CZX) Pressure range Coding Flow rate Qmax (lpm) Flow rate Qmax (lpm) Short model (not for type LZ) prepared, with tapped plug * not for type LZ ** Value in brackets dene the pressure stage

 Open the catalog to page 12
BA-13

Pressure adjustment Coding Circuit symbol Without coding Fixed, tool adjustable Manually adjustable, with lock nut not directly combinable next to each other Turn knob, lockable not for type LZ Check valve Coding without check valve in P with check valve in P (not for type CZD) 2.4.2 Intermediate plate for a 2nd Speed Application: Optional switching to a second speed, for example for set-up mode or to vary the ow rate to traverse speed proles. Ordering example BA 2 A5 -G 24 2.4.3.1 "Solenoid voltage and solenoid male connector for proportional solenoid" Orice in the P channel Intermediate...

 Open the catalog to page 13
BA-14

Coding ZPL/SP Coding ZPL/S(PG)/PB... Coding ZPL/S(PG)/P Coding ZPL/VP Coding ZPL/V(PG)/PB... Coding ZPL/V(PG)/P Orice in the P channel Coding closed (not sealed for zero leakage) DAMAGE Not in combination with coding ZPL/VP and ZPL/SP.

 Open the catalog to page 14
BA-15

2.4.3 Intermediate plate with proportional pressure-limiting valve for second pressure circuit in BA valve bank Application: Compact solution for two pressure circuits in one valve bank. DAMAGE Combination with a dual-circuit pump, for example type HK 4 to D 7600-4 and a connection block type Sk 6905 Z/AP is feasible. Circuit symbol Prop. pressure-limiting valve ZPL / P.. Example schematic plan Check valve at P (optional) max. pressure setting of pressure-limiting valve (bar) MVF 2.4.3.1 "Solenoid voltage and solenoid male connector for proportional solenoid" "Proportional pressure-limiting valve"...

 Open the catalog to page 15

All HAWE Hydraulik SE catalogs and technical brochures

  1. VR

    15  Pages

  2. BVE

    54  Pages

  3. SLC

    17  Pages

  4. BNG

    25  Pages

  5. VB

    88  Pages

  6. VP

    35  Pages

  7. VH

    6  Pages

  8. SL1

    15  Pages

  9. ROLV

    23  Pages

  10. EM

    41  Pages

  11. PS

    20  Pages

  12. K60N

    19  Pages

  13. V30D

    60  Pages

  14. V80M

    30  Pages

  15. V30E

    51  Pages

  16. RZ

    12  Pages

  17. C40V

    47  Pages

  18. HR 080

    17  Pages

  19. HICON

    14  Pages

  20. INKA

    35  Pages

  21. FXU

    35  Pages

  22. V60N

    71  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.