tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial Black", sans-serif; } .font4 { font:13.00pt "Arial Black", sans-serif; } .font5 { font:5.00pt "Microsoft Sans Serif", sans-serif; } .font6 { font:6.00pt "Microsoft Sans Serif", sans-serif; } .font7 { font:9.00pt "Microsoft Sans Serif", sans-serif; } HAUG lonization -for the limination of electrostatic charges Statik-Air 09 - System Dr. Escherich These units are used for removing dust from surfaces. The functional modules consist of ionization, air jet and extraction. These modules are coordinated effectively within a closed system. Function The Statik-Air 09 web dusting unit is connected to a high-voltage power pack. The air jet and extraction units can either be connected to existing utilities or to specially designed accessories. The following ionizing bar can be combined with the Statik-Air 09 housing: Ionizing bar EI PRX Pulsed operation The application of Statik-Air systems in pulsed operation can be recommended for media transported with intermediate distances/gaps. Advantage: reduced costs (e.g. for compressed air). Pulsed operation can be controlled by external input to the switchgear, e.g. using photoelectric sensors, proximity switches or other potential-free contacts. Continuous operation The application of Statik-Air systems in continuous operation can be recommended if the medium to be cleaned passes through continously. Switchgear The switchgear is equipped with 3 functional modules: 镕 Power supply with power circuit breaker, motor circuit breaker for extractor fan, ON/OFF switch and control lamps. Should it be necessary to connect two extractor fans to one switchgear, the relevant versions can also be supplied. Solenoid valve for compressed air control with time-delay switch for pulsed operation. Օ High-voltage power pack with 4 high-voltage terminals. The watchdog integrated in the secondary area (ill. 1) signals a drop below the corona inception voltage. ill.2 Compressed air Compressed air of a quality suitable for spraying applications must be available, i.e. it must be free of oil and water. The upstream installation of a service unit with integrated oil and water separator is recommended. Web speeds The maximum web speed of the standard version is approx. 80 m/min. Higher speeds are available on request. Typical applications Plastics, furniture, paper, print, film, foil, automotive, electrical and other industries. ill.4 30- 5 bar e >^ ^ 4 bar z 24- 3 bar c O q. 18- 2 bar e 3 12- 1 bar cons 6- jj 0 < 20 40 60 80 100 120 140 160 180 200 Extraction width in cm Air consumption diagram Air consumption in N m3/h as a function of extraction width and operating pressure (ill.4) ill.3 HAUG GmbH & Co. KG Germany Friedrich-List-Str. 18 D-70771 Leinf.-Echterdingen Phone: +49 711 / 94 98-0 Telefax: +49 711 /94 98-298 HAUG Biel AG www.haug.de E-mail: info@haug.de Switzerland Johann-Renfer-Str. 60 CH-2500 Biel-Bienne 6 Phone: +41 32 / 344 96 96 Telefax: +41 32 / 344 96 97 www.haug-ionisation.com E-mail: info@haug-biel.ch
Open the catalog to page 1tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial Black", sans-serif; } Technical data Statik-Air 09 Type: Dimensions: Lengths: SA 09 80 x 35 mm Order-No.: 04.0110.000 45 to 1200 mm (larger lengths on request) Weight: approx. 4 kg/m Cable outgoing: available right or left Operating temperature: +5 °C to +45 °C Storage/transport temperature: -15 °C to +60 °C Smallest bending radius (cable): R 50 Subject to technical changes! Zubehr Compressed-air hose 0 12x9mm Radial fan...
Open the catalog to page 2All HAUG catalogs and technical brochures
-
Ionizing unit NI
2 Pages
-
Ionizing unit LS GK
2 Pages
-
Ionizing unit EI VS
2 Pages
-
Ionizing unit EI VC
2 Pages
-
Ionizing unit EI RN
2 Pages
-
Ionizing unit EI SL
2 Pages
-
Power pack EN 9 Sine
2 Pages
-
Power pack Multistat Plus
2 Pages
-
Power pack Multistat
2 Pages
-
Air Line - Circle Cleaner 01
2 Pages
-
Ionizing unit AJ
2 Pages
-
Ionizing unit BI
2 Pages
-
IML - In Mould Labelling
1 Pages
-
Analytical weighing
4 Pages
-
Single cable technology
4 Pages
-
Clean room
2 Pages
-
Tampon print
2 Pages
-
Folding machines
2 Pages
-
Active ionizers
6 Pages
-
Counter electrodes
1 Pages
-
Bar holder
2 Pages
-
System X-2000
2 Pages
-
Cleaning systems RS 1 / RS 2
1 Pages
-
Perforation counter PZ 3
2 Pages
-
Anti-Neck-In-Triode ANT
2 Pages
-
Charging electrode ALW
1 Pages
-
Charging bar ALS
2 Pages
-
Statik-Air 08
2 Pages
-
Ionizing air gun RI LG
2 Pages
-
Needle ionizer NI
2 Pages
-
Mini-Jet Ionisator MJ I
2 Pages
-
Air gate KL GK (Uno)
2 Pages
-
Ring ionizer EI RIF
2 Pages
-
Delta blower DA TR
2 Pages
-
Air Knife AK GK
2 Pages
-
One-Point-Ionizer OPI
2 Pages
-
Ionizing bar EI HRN
2 Pages
-
Segment-Ionisator EI Form
2 Pages
-
Power Pack EN 70 / EN 70 LC
2 Pages