Introduction to Electrostatic Charges: The document begins by explaining the origin of electrostatic charges, traditionally attributed to friction (tribo-electricity), but now understood through semiconductor physics. When two materials come into contact, electron migration occurs due to differing electron work functions, creating a voltage at the Helmholtz double layer.
Ionizers and Static Electricity: Ionizers are devices used to manage static electricity, which can occur in both insulators and ungrounded conductors. Static electricity is common in nature and industrial processes, such as in the textile and plastics industries, where it can cause operational issues.
Functioning of Active Ionizers: Active ionizers, particularly those using alternating current, are described. These devices generate ions to neutralize static charges on materials. HAUG ionizers are noted for their safety features, such as galvanic separation of pins from high voltage.
Interference from Electrostatic Charges: The document details the problems caused by electrostatic charges in the textile industry, including thread breakage and fabric handling issues, and how ionizers can mitigate these problems.
Types of Ionizers: Both passive and active ionizers are discussed. Passive ionizers use metallic tips to induce corona discharge, while active ionizers use high voltage to generate ions. Air-assisted ionizers extend the range of ionization by using compressed air to transport ions.
Measuring Static Electricity: Methods for measuring static electricity are outlined, including the use of field strength meters and modulation measuring units, which operate without contact to assess the electrical field's magnitude and polarity.
Applications and Products: HAUG offers a variety of ionization systems, including air-assisted ionizers and web cleaning systems, which are crucial for maintaining material cleanliness in industries like paper and textiles.
Conclusion: The document concludes with a brief overview of HAUG's product offerings and contact information for their global offices.
See more

Catalog excerpts

Active ionizers-1

SteffenUlrichHomolka Diplom-Ingenieur HAUGGmbH&Co.KG >

 Open the catalog to page 1
Active ionizers-2

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:12.00pt "Arial", sans-serif; } .font4 { font:13.00pt "Arial", sans-serif; } .font5 { font:36.00pt "Arial", sans-serif; } .font6 { font:8.00pt "Arial Black", sans-serif; } .font7 { font:12.00pt "Arial Black", sans-serif; } .font8 { font:33.00pt "Arial Black", sans-serif; } .font9 { font:7.00pt "Times New Roman", serif; } .font10 { font:26.00pt "Trebuchet MS", sans-serif; } How active ionizers function...

 Open the catalog to page 2
Active ionizers-3

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:17.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial Black", sans-serif; } .font4 { font:33.00pt "Arial Black", sans-serif; } .font5 { font:7.00pt "Times New Roman", serif; } Measuring static electricity It is possible to measure static electricity indirectly by registering the effects it produces. Nowadays, field strength meters, which use the influence or modulation measuring method, are used. These devices operate without contact and...

 Open the catalog to page 3
Active ionizers-4

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:20.00pt "Arial", sans-serif; } .font4 { font:7.00pt "Arial Black", sans-serif; } .font5 { font:44.00pt "Franklin Gothic Medium", sans-serif; } @[2 Passive ionizer Passive ionizers are constructed such that metallic tips are connected with the earth. If such an ionizer is brought near a charged material, a corona discharge is induced in the pins of the ionizer, thereby generating ions. The effect of...

 Open the catalog to page 4
Active ionizers-5

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:32.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial Black", sans-serif; } .font4 { font:24.00pt "Arial Black", sans-serif; } .font5 { font:10.50pt "Trebuchet MS", sans-serif; } ©s Air-assisted active ionizers lonizers of the kind described in the preceding section have an inhrent disadvantage in that their range is relatively narrow (10 mm up to max. 200 mm). Since ions of both polarities are generated, the ions generated recombine at...

 Open the catalog to page 5
Active ionizers-6

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial Black", sans-serif; } D-0099-GB- 06/05-V1.2 HAUG GmbH & Co. KG Germany Friedrich-List-Str. 18 D-70771 Leinf.-Echterdingen Phone: +49 711 / 94 98-0 Telefax: +49 711 /94 98-298 www.haug.de E-mail: [email protected] HAUG Biel AG Switzerland Johann-Renfer-Str. 60 CH-2500 Biel-Bienne 6 Phone: +41 32/344 96 96 Telefax: +41 32/344 96 97 www.haug-ionisation.com E-mail: [email protected] HAUG North America Canada Limited Partnership 1200 Aerowood...

 Open the catalog to page 6

All HAUG catalogs and technical brochures

  1. Clean room

    2  Pages

  2. Tampon print

    2  Pages

  3. Bar holder

    2  Pages

  4. System X-2000

    2  Pages

  5. Statik-Air 09

    2  Pages

  6. Statik-Air 08

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.