Liquid Pumps
28Pages

{{requestButtons}}

Catalog excerpts

Liquid Pumps - 1

Pressure on Demand Pneumatic Driven Liquid Pumps

Open the catalog to page 1
Liquid Pumps - 2

High Pressure Haskel pneumatic driven liquid pumps are designed to provide a safe, reliable and economical, source of hydraulic pressure. This brochure introduces our pneumatic driven liquid pump range. Visit our website at www.haskel.com for more information or to locate a distributor. Why Use Haskel Pneumatic Driven Pumps? Our pumps offer many advantages over electrically driven pumps: • • • • • • • • Safe pneumatic operation – no heat, flame or spark risk Up to 100,000 psi (7000 bar) capability Infinitely variable cycling speed Stall feature at pre-determined pressure to hold that pressure...

Open the catalog to page 2
Liquid Pumps - 3

Pressure and Flow on Demand This guide will help you to pre-select the pump ideally suited for your application. If you have specific questions, however, we urge you to provide Haskel with the operational details of your application. We will recommend a model and any corresponding accessories. Output Horsepower Ratings The pumps are categorized on their horsepower ratings (see pages 6-7). These are approximate and peak at 100 psi (7 bar), assuming adequate drive, pressure and volume. Peak horsepower is at about 75% nominal ratio x drive pressure, i.e. 100:1 pump @ 100 psi air drive peaks at...

Open the catalog to page 3
Liquid Pumps - 4

2. Hydraulic Check Valves Anatomy of a Pneumatic Driven Pump 1. Drive Section The piston, complete with “O” ring seal, operates in an epoxy filled, fiberglass wound barrel, the diameter of which is constant throughout a given series of pumps. Drive media forces the piston down on the compression stroke and raises it on the suction stroke (M series have a spring return). The piston is pre-lubricated during assembly and therefore no air line lubricator is necessary. 2. Hydraulic Section/Check Valves The drive piston is linked and connected to the hydraulic plunger/piston in the hydraulic...

Open the catalog to page 4
Liquid Pumps - 5

WETTED MATERIALS OF CONSTRUCTION AND SERVICES MODEL WETTED MATERIALS PUMP SECTION Cad plated steel, Aluminum & SS Urethane, PTFE, Buna UHMWPE, PTFE, Buna Hard Chrome Plated 15.5PH SS + Dichronite UHMWPE, PTFE, Ryton Stainless Steel and Aluminum Viton, PTFE Stainless Steel and Aluminum Viton, PTFE PTFE, Viton, Ryton Aluminum(Hard coated) UHWMPE, Buna UHWMPE, Buna Nickel Plated Steel & SS Urethane, Buna N, PTFE UHMWPE, Buna, PTFE, Ryton Separation - Nickel Plated Steel & SS UHMWPE, Viton, PTFE, Ryton 440OC SS Hard Chrome Plated UHMWPE, Viton, PTFE, Ryton Nickel Plated Steel & SS PTFE, Viton...

Open the catalog to page 5
Liquid Pumps - 6

Performance and Specification Overview Maximum Rated Output Pressure Pump Model Code DXHF, DSXHF DXHF, DSXHF 8DSFD 8HSFD 8SFD2 (Double Air Drive Piston Models) Maximum Flow Ratio Dash Actual Area no. Ratio

Open the catalog to page 6
Liquid Pumps - 7

Typical Performance using 100 psi (7 bar) Air drive Outlet Pressure Outlet Flow Outlet Pressure Outlet Flow Pump Selection Information All Haskel pumps are identified by letters coding the type of pump, followed by a number indicating the practical working ratio of the drive area to the hydraulic plunger area. These letters are explained in the chart below. Pump Model Letter Coding Pump incorporates a Distance Piece Double Acting pump 1” stroke .75 hp pump series (bottom inlet only) 2” stroke 1.5 + 2 hp pump series 2” stroke 1.5 + 2 hp High Pressure pump series Filter, regulator with gauge...

Open the catalog to page 7
Liquid Pumps - 8

.33 hp (.25 kW) M Series Pump Models Nominal Ratio Maximum Working Pressure Consult chart on page 6 for more information regarding continuous/intermittent pressures. • Choice of wetted materials • Single air head • Drive pressure 25 to 125 psi (1.8 to 9 bar) • All Hydraulic fluids, water (plain or DI), solvents, mild chemicals, liquefied gases Key Features • Choice of 6 models, 9 ratios, 27 possible combinations For service codes, see page 17. For weights and dimensions, see page 18. Optional Modifications Number Hand pump attachment (with handle). Provides manual operation of pump for...

Open the catalog to page 8
Liquid Pumps - 9

Maximum Working Pressure Nominal Ratio Consult chart on page 6 for more information regarding continuous/intermittent pressures. For service codes, see page 17. For weights and dimensions, see page 18. Key Features • One model available in 9 ratios • Choice of wetted materials Optional Modifications Number Air drive controls. Extreme cycling service. Not recommended for long stall periods. External air pilot. Provides 1⁄8” NPT port for external air to pilot for remote start/ stop operation. Low drive air pressure. Allows user to regulate drive air to as low as 3 psi (.2 bar). Single acting...

Open the catalog to page 9
Liquid Pumps - 10

Maximum Working Pressure Nominal Ratio Consult chart on page 6 for more information regarding continuous/intermittent pressures. Key Features • Choice of 11 models, 13 ratios, 50 possible combinations • Output pressures to 50,000 psi (3448 bar) • Flows to 22 gpm (83.0 l/min) • Choice of wetted materials • Single air head • Drive pressure 3 to 150 ps (.2 to 10 bar) (1) These series are “Lift” pumps and maximum outlet pressure is (air drive x pump ratio) + inlet pressure (2) DTV has poppet checks For service codes, see page 17. For weights and dimensions, see page 20. Optional Modifications...

Open the catalog to page 10
Liquid Pumps - 11

1.5 hp (1.12 kW) High Output Flow Pumps Available in a choice of 4 models, these high output, low ratio pumps are capable of pressures to 1200 psi (82 bar) and flow rates of up to 22 gpm (83 l/min). These are “lift” pumps whereby the outlet pressure equals the air drive x the pump ratio plus the inlet pressure. Mounting Brackets All series mounting brackets have 7/16” holes (slots) for 3/8” bolts. Upper mounting brackets are not furnished as standard on single air head non-distance piece units. Dimensional Data Mounting Brackets Model DSTV-1.5 has a maximum air drive of 150 psi (10 bar) and...

Open the catalog to page 11
Liquid Pumps - 12

Maximum Working Pressure Nominal Ratio Consult chart on page 6 for more information regarding continuous/intermittent pressures. • Flows to 5 gpm (15 l/min) • Choice of wetted materials • Double and triple air heads • Drive pressure 3 to 100 psi (.2 to 7 bar) When using high pressure ratio pumps the reliability of the XH models (-452 through -1373) will be improved with an air driven supercharge pump, not only to simplify priming but to reduce fatigue stresses. The higher the supercharge, the better the results. Also install a relief valve to protect the lower pressure pump from potential...

Open the catalog to page 12

All Haskel catalogs and technical brochures

  1. Subsea Valves

    18 Pages

  2. Butech Oil Gas

    12 Pages

  3. HGD-90

    2 Pages

  4. HGD-150

    2 Pages

  5. HGT-90/63

    2 Pages

  6. HGT-150/63

    2 Pages

  7. HGT-150/90

    2 Pages

  8. ScubAmp

    2 Pages

  9. Oil and Gas

    6 Pages

  10. H-Drive

    4 Pages

  11. Oil & Gas

    6 Pages

  12. Gas Boosters

    36 Pages

Archived catalogs