Specifications:
  • Max Gas Inlet Pressure: 4060 psi (280 Bar)
  • Min Gas Inlet Pressure: 50 psi (3.5 Bar)
  • Max Gas Outlet Pressure: 15,000 psi (1034 Bar)
  • Max Hydraulic Drive Pressure: 3600 psi (250 Bar)
  • Gas Piston Displacement: 118 Cu Ins (1.94 Litres)
  • Max Recommended Compression Ratio (CR): 36:1
Performance Chart:
  • Illustrates the relationship between gas supply pressure and outlet flow rate.
  • Minimum gas inlet pressure is 3.5 Bar g (50 psig).
  • Maximum gas inlet pressure is 280 Bar g (4060 psig).
  • Maximum gas outlet pressure is 1034 Bar g (15,000 psig).
Procedures and Recommendations:
  • Ensure venting to a controlled environment, not exceeding 50 psig back pressure.
  • Remove plug upon installation and direct it to an oil catch tray.
  • Torque specifications for various components are provided, such as tie rods, screws, cooling connections, hydraulic connections, check valves, and vent connections.
  • Reverify all torque values after testing.
  • Drain coolant through the specified port before shipping and for maintenance intervals.
  • Touch up hydraulic cylinder paint before shipping using black paint RAL 9005.
  • Plug all open ports with plastic caps before shipping.
Parts List:
  • Includes components such as hydraulic cylinder assembly, gas section assemblies, inlet and outlet check valve assemblies, washers, nuts, retainer caps, O-rings, and screws.
  • Materials include stainless steel metallic body, spring-activated seals, rubber O-rings, coated steel fasteners, and washers.
Operating Parameters:
  • To determine required cycling speed, draw a horizontal line for required outlet flow and a vertical line for available gas supply pressure. The intersection indicates the approximate cycling speed of the H-Drive.
  • For full operating parameters, contact the factory or distributor with data on gas supply pressure, gas outlet pressure, required outlet flow, gas being transferred, and application details.
See more

Catalog excerpts

HGT-90/63-1

TERIALS: STAINLESS STEEL METALIC BODY, SPRING ACTIVATED SEALS, RUBBER O-RINGS, OATED STEEL FASTENERS AND WASHERS E SHEET 2 FOR GENERAL ARRANGEMENT DIMENSIONS NT TO A CONTROLLED ENVIRONMENT. NOT TO EXCEED 50 PSIG BACK PRESSURE MOVE PLUG UPON INSTALLATION & DIRECT IT TO AN OIL CATCH TRAY YDRAULIC CYLINDER SEAL KIT - 88065 H-Drive Booster Model HGT-90/63 AT SIDE OF WASHERS TO FACE THE NUTS 10 FT-LBS, 16 PLACES. APPLY ANTI-SEIZE COMPOUND TO THREADS Min Gas inlet Max. rec. Max AVE AT LEAST 3 THREADS OUTMax Gas Inlet EACH SIDE. TIGHTEN IN 100 FT-LBS INCREMENTS OF THE NUTS ON RQUE COOLING CONNECTIONS TO 50±10 FT-LBS Max Hydraulic Drive Pressure Psi g 3600 RQUE HYDRAULIC CONNECTIONS TO 200±10 FT-LBS RQUE CHECK VALVES TUBES TO 50±10 FT-LBS RQUE VENT CONNECTIONS TO 50±10 FT-LBS To determine required cycling speed: VERIFY ALL TORQUE VALUES AFTER TESTING AIN COOLANT THROUGH THIS PORT BEFORE SHIPPING & FOR MAINTENANCE INTERVALS Outlet Flow Nm3/hr (scfm) Minimum Gas inlet : 3.5 Bar g (50 psig) ORQUE THE PLUG NO MORE THAN 400 25 FT-LBS Maximum Gas Inlet : 280 Bar g (4,060 psig) (236) Maximum Gas Outlet : 1034 Bar g (15,000 psig) UCH UP HYDRAULIC CYLINDER PAINT BEFORE SHIPPING. USE BLACK PAINT RAL 9005. Maximum Recommended CR : 36:1 2. Draw vertical line representing the gas Parts List supply pressure available ITEM HGT-90/63-1-0 HGT-90/63-2-0 DESCRIPTION 3. Where both lines cross will give STROKE, 3800 PSI 1 88062 88062 HYD CYLINDER ASSY, 150MM BORE, 12"the 2 88096 GAS SECTION ASSY, 90MM, 12" STROKE, H-DRIVE approx. cycling speed of the H-Drive Qo88096-2 - 15 3 88097 88097-2 GAS SECTION ASSY, 63MM, 12" STROKE, H-DRIVE CPM For full operating parameters of H-Drive 4 88116 88116-2 INLET CHECK VALVE ASSY, HDGB running at ASSY, OUTLET, H-DRIVE 5 88117 CHECK VALVEparticular conditions including 88117-2 the TORQUE INSTRUCTIONS, H-DRIVE 6 88125 88125 LABEL,hydraulic power supply required, contact factory or PLATE, H-DRIVE 7 88137 88137 LABEL, NAMEdistributor with following data: 11 CNF00383 CNF00383 WASHER, Gas supply pressure • Ps HYTORC, STEEL, BLACK OXIDE, 24MM BOLT QoCNF00384 - 10 12 CNF00384 NUT, STEEL, GRADE 8, ZINC PLATE, M24X3, 19MM LONG CPM • Po CAP 14 86579 86579 RETAINERGas outlet pressure 15 568018-9 568018-9 O-RING Outlet flow required • Qo 16 CNF00385 CNF00385 SCREW,SOCK HEAD 1/4-20X7/8 THIS DRAWING EMBODIES A • Gas being ASSY (REF ONLY) NEXT transferred Haskel Internationa N EACH GAS SECTION, ONLY ENGAGE ONE SCREW THRU THE BRACKET. 350 UG ALL OPEN PORTS WITH PLASTIC CAPS BEFORE SHIPPING CONFIDENTIAL PROPRIETARY DESIGN, ALL RIGHTS FOR REPRODUCTION, MANUFACTURING OR PATENTS ARE RESERVED BY HASKEL INTERNATIONAL, LLC. INFORMATION CONTAINED HEREIN IS SUBJECT TO THE EXPORT ADMINISTRATION REGULATIONS (EAR) OF THE UNITED STATES OF AMERICA AND EXPORT CLASSIFIED UNDER THOSE REGULATIONS AS (ECCN: EAR99). NO PORTION OF THIS DOCUMENT CAN BE RE-EXPORTED FROM THE RECIPIENT COUNTRY OR RE-TRANSFERRED OR DISCLOSED TO ANY OTHER ENTITY OR PERSON NOT AUTHORIZED TO RECEIVE IT WITHOUT THE PRIOR AUTHORIZATION OF HASKEL INTERNATIONAL, LLC. THIS NOTICE SHALL BE ATTACHED TO ANY REPRODUCED SECTION OF THIS DOCUMENT. 1. Draw horizontal line representing required outlet flow Gas Supply Pressure Bar g (psig) FRACTIONS: ANGLES: Burbank, California THIRD ANGLE PROJECTION GAS BOOSTER, H-DRIVE STROKE, HGT-90/63 88124-TAB 81400 CAGE CODE