Specifications:
  • Max Gas Inlet Pressure: 4500 psi (310 Bar g)
  • Min Gas Inlet Pressure: 50 psi (3.5 Bar g)
  • Max Gas Outlet Pressure: 4500 psi (310 Bar g)
  • Max Hydraulic Drive Pressure: 3600 psi (250 Bar g)
  • Gas Piston Displacement: 658 cu ins (10.77 litres)
  • Max Recommended Compression Ratio (CR): 6:1
Performance Chart:

The performance chart illustrates the relationship between gas supply pressure and outlet flow rate at different cycling speeds (CPM). The chart helps determine the required cycling speed by intersecting the horizontal line of required outlet flow with the vertical line of available gas supply pressure.

Procedures and Recommendations:
  • Ensure venting to a controlled environment with a back pressure not exceeding 50 psig.
  • Remove plug upon installation and direct it to an oil catch tray.
  • Use the specified seal kits for maintenance: Gas Section Seal Kit - 88138, Hydraulic Cylinder Seal Kit - 88065.
  • Torque specifications for various components are provided, such as tie rods, prox switch screws, cooling connections, hydraulic connections, check valves tubes, and vent connections.
  • Reverify all torque values after testing.
  • Drain coolant through the specified port before shipping and during maintenance intervals.
  • Touch up hydraulic cylinder paint with black paint RAL 9005 before shipping.
  • Plug all open ports with plastic caps before shipping.
Parts List:

The document includes a detailed parts list with quantities and part numbers for components such as screws, O-rings, retainer caps, hydraulic cylinder assembly, gas section assembly, inlet and outlet check valve assemblies, labels, washers, and nuts.

Notes:
  • Materials include stainless steel metallic body, spring-activated seals, rubber O-rings, and coated steel fasteners and washers.
  • General arrangement dimensions are available on sheet 2.
  • For full operating parameters, contact the factory or distributor with specific data such as gas supply pressure, gas outlet pressure, required outlet flow, gas being transferred, and application details.
See more

Catalog excerpts

HGD-150-1

ATERIALS: STAINLESS STEEL METALIC BODY, SPRING ACTIVATED SEALS, RUBBER O-RINGS, OATED STEEL FASTENERS AND WASHERS EE SHEET 2 FOR GENERAL ARRANGEMENT DIMENSIONS ENT TO A CONTROLLED ENVIRONMENT. NOT TO EXCEED 50 PSIG BACK PRESSURE EMOVE PLUG UPON INSTALLATION & DIRECT IT TO AN OIL CATCH TRAY YDRAULIC CYLINDER SEAL KIT - 88065 H-Drive Booster Model HGD-150 LAT SIDE OF WASHERS TO FACE THE NUTS 10 FT-LBS, 16 PLACES. APPLY ANTI-SEIZE COMPOUND TO THREADS EAVE AT LEAST 3 THREADS OUT OF THE NUTS ON EACH SIDE. TIGHTEN IN 100 FT-LBS INCREMENTS ORQUE PROX SWITCH SCREWS TO Pressure 8 .5 FT-LBS Psi 50±10 FT-LBS Bar g ORQUE COOLING CONNECTIONS TOg 4500 310 ORQUE HYDRAULIC CONNECTIONS TO 200±10 FT-LBS Max Hydraulic Drive Pressure Psi g 3600 ORQUE CHECK VALVES TUBES TO 50±10 FT-LBS ORQUE VENT CONNECTIONS TO 50±10 FT-LBS EVERIFY ALL TORQUE VALUES AFTER TESTING (1180) RAIN COOLANT THROUGH THIS PORT BEFORE SHIPPING & FOR MAINTENANCE INTERVALS To determine required cycling speed: Minimum Gas inlet : 3.5 Bar g (50 psig) Maximum Gas Inlet : 310 Bar g (4,500 psig) OUCH UP HYDRAULIC CYLINDER PAINT BEFORE SHIPPING. USE BLACK PAINT RAL:9005. Bar g (4,500 psig) Maximum Gas Outlet 310 1600 (942) N EACH GAS SECTION, ONLY ENGAGE ONE SCREWMaximum Recommended CR : 6:1 THRU THE BRACKET. 1. Draw horizontal line representing required outlet flow Outlet Flow Nm3/hr (scfm) ORQUE THE PLUG NO MORE THAN(1059) 25 FT-LBS 2. Draw vertical line representing the gas Parts pressure available supply List ITEM P/N HGD-150-1-0 P/N HGD-150-2-0 DESCRIPTION 3. Where both lines cross will 14 CNF00385 CNF00385 SCREW,SOCK HEAD 1/4-20X7/8 give the approx. cycling speed of the H-Drive 13 568018-9 568018-9 O-RING Qo - 15CPM 12 86579 86579 RETAINER CAP For full operating parameters of H-Drive 1 88062 88062 HYD CYLINDER ASSY, 150MM BORE, 12" STROKE, 3800 PSI running at particular conditions including 2 88095 88095-2 GAS SECTION ASSY, 150MM, 12" STROKE, H-DRIVE the hydraulic power supply required, contact 3 88116 88116-2 INLET CHECK VALVE ASSY, HDGB factory or distributor with following data: 4 88117 88117-2 CHECK VALVE ASSY, OUTLET, H-DRIVE • Ps Gas supply pressure 5 88125 88125 LABEL, TORQUE INSTRUCTIONS, H-DRIVE Qo - 10CPM 6 88137 88137 LABEL, NAME outlet pressure • Po Gas PLATE, H-DRIVE 10 CNF00383 CNF00383 WASHER, HYTORC, STEEL, BLACK OXIDE, 24MM BOLT • Qo Outlet flow required 11 CNF00384 CNF00384 NUT, STEEL, GRADE 8, ZINC PLATE, M24X3, 19MM LONG UG ALL OPEN PORTS WITH PLASTIC CAPS BEFORE SHIPPING 1400 THIS DRAWING EMBODIES A CONFIDENTIAL PROPRIETARY DESIGN, ALL RIGHTS FOR REPRODUCTION, MANUFACTURING OR PATENTS ARE RESERVED BY HASKEL INTERNATIONAL, LLC. INFORMATION CONTAINED HEREIN IS SUBJECT TO THE EXPORT ADMINISTRATION REGULATIONS (EAR) OF THE UNITED STATES OF AMERICA AND EXPORT CLASSIFIED UNDER THOSE REGULATIONS AS (ECCN: EAR99). NO PORTION OF THIS DOCUMENT CAN BE RE-EXPORTED FROM THE RECIPIENT COUNTRY OR RE-TRANSFERRED OR DISCLOSED TO ANY OTHER ENTITY OR PERSON NOT AUTHORIZED TO RECEIVE IT WITHOUT THE PRIOR AUTHORIZATION OF HASKEL INTERNATIONAL, LLC. THIS NOTICE SHALL BE ATTACHED TO ANY REPRODUCED SECTION OF THIS DOCUMENT. Gas Supply Pressure Bar g (psig) NEXT ASSY (REF ONLY) FILLETS & RADII .005 [.12]-.030 [.76] TOLERANCES ARE: DECIMALS: Haskel Internation Burbank, California THIRD ANGLE PROJECTION GAS BOOSTER, H-DRIVE STROKE, HGD-150 88092-TAB 81400 CAGE CODE