1. Catalogs
  2. Haskel
  3. H-Drive Cut Sheets
video corpo

H-Drive Cut Sheets

H-Drive Cut Sheets

H-Drive Cut Sheets

Product catalog summary
Specifications:
  • Max Gas Inlet Pressure: 15,000 psi (1034 bar)
  • Min Gas Inlet Pressure: 100 psi (6.9 bar)
  • Max Recommended Compression Ratio (CR): 6:1
  • Max Gas Outlet Pressure: 15,000 psi (1034 bar)
  • Max Hydraulic Drive Pressure: 3600 psi (250 bar)
  • Gas Piston Displacement: 116 cubic inches (1.9 litres)
Parts List:
  • Hydraulic Cylinder Assembly: 150mm bore, 12" stroke, 3800 psi
  • Gas Section Assembly: 63mm, 12" stroke
  • Inlet and Outlet Check Valve Assemblies
  • Torque Instruction and Name Plate Labels
  • Various washers, nuts, and screws
Procedures and Recommendations:
  • Ensure all dimensions are in inches or millimeters as specified.
  • Remove burrs and ensure machine finish is 125 [3.2].
  • Follow specified torque values for various components, such as tie rods, prox switch plugs, and connections.
  • Vent to a controlled environment, not exceeding 50 psig back pressure.
  • Use anti-seize compound on threads and ensure proper engagement of screws and plugs.
  • Touch up hydraulic cylinder paint with black paint RAL 9005 before shipping.
  • Plug all open ports with plastic caps before shipping.
Graphical Data:
  • The graph illustrates the relationship between gas supply pressure and outlet flow rate, with cycling speed determined by the intersection of horizontal and vertical lines representing these parameters.
  • Minimum gas inlet pressure is 7 Bar g (100 psig), and maximum gas inlet pressure is 1034 Bar g (15,000 psig).
Additional Notes:
  • For full operating parameters, contact the factory or distributor with specific data such as gas supply pressure, outlet pressure, required outlet flow, gas type, and application details.
See more

Catalog excerpts

H-Drive Cut Sheets-1

T 2 FOR GENERAL ARRANGEMENT DIMENSIONS A CONTROLLED ENVIRONMENT. NOT TO EXCEED 50 PSIG BACK PRESSURE PLUG UPON INSTALLATION & DIRECT IT TO AN OIL CATCH TRAY E OF WASHERS TO FACE THE NUTS TIE RODS TO 410 10 FT-LBS, 16 PLACES. APPLY ANTI-SEIZE COMPOUND TO THREADS LEAST 3 THREADS OUT OF THE NUTS ON EACH SIDE. TIGHTEN IN 100 FT-LBS INCREMENTS PROX SWITCH PLUGS TO 65 5 FT-LBS. MAKE METAL TO METAL CONTACT. EXTRUSION ALLOWED H-Drive Booster Model HGD-63 COOLING CONNECTIONS TO 50±10 FT-LBS HYDRAULIC CONNECTIONS TO 200±10 FT-LBS CHECK VALVES TUBES TO 50±10 FT-LBS VENT CONNECTIONS TO 50±10 FT-LBS 15000 Max Hydraulic Drive Pressure ALL TORQUE VALUES AFTER TESTING OOLANT THROUGH THIS PORT BEFORE SHIPPING & FOR MAINTENANCE INTERVALS THE PLUG NO MORE THAN 30±5 FT-LBS P HYDRAULIC CYLINDER PAINT BEFORE SHIPPING. USE BLACK PAINT RAL 9005. (706) GAS SECTION, ONLY ENGAGE ONE SCREW THRU THE BRACKET. OPEN PORTS WITH PLASTIC CAPS BEFORE SHIPPING Minimum Gas inlet : 7 Bar g (100 psig) Maximum Gas Inlet : 1034 bar g (15,000 psig) Maximum Gas Outlet : 1034 Bar g (15,000 psig) Maximum Recommended CR : 6:1 Outlet Flow Nm3/hr (scfm) THIS DRAWING EMBODIES A CONFIDENTIAL PROPRIETARY DESIGN, ALL RIGHTS FOR REPRODUCTION, MANUFACTURING OR PATENTS ARE RESERVED BY HASKEL INTERNATIONAL, LLC. INFORMATION CONTAINED HEREIN IS SUBJECT TO THE EXPORT ADMINISTRATION REGULATIONS (EAR) OF THE UNITED STATES OF AMERICA AND EXPORT CLASSIFIED UNDER THOSE REGULATIONS AS (ECCN: EAR99). NO PORTION OF THIS DOCUMENT CAN BE RE-EXPORTED FROM THE RECIPIENT COUNTRY OR RE-TRANSFERRED OR DISCLOSED TO ANY OTHER ENTITY OR PERSON NOT AUTHORIZED TO RECEIVE IT WITHOUT THE PRIOR AUTHORIZATION OF HASKEL INTERNATIONAL, LLC. THIS NOTICE SHALL BE ATTACHED TO ANY REPRODUCED SECTION OF THIS DOCUMENT. UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES [MM] DO NOT SCALE DRAWING REMOVE BURRS MACHINE FINISH 125 [3.2] TOLERANCES ARE: Gas Supply Pressure Bar g (psig) Haskel International, LLC Burbank, California 91502 GAS BOOSTER, H-DRIVE, 12" STROKE, HGD-63 • Qo Outlet flow required 88094-TAB_MARKETIN D 81400 DATE • Po Gas outlet pressure DRAWN PM 9/27/2016 CAGE CODE CAD being 88094 • GasFILENAME transferred NONE SCALE: NEXT ASSY (REF ONLY) THIRD ANGLE PROJECTION To determine required cycling speed: Parts List DESCRIPTION 1. Draw horizontal line representing HYD CYLINDER ASSY, 150MM BORE, 12" STROKE, 3800 PSI required outlet flow GAS SECTION ASSY, 63MM, 12" STROKE, H-DRIVE 2. Draw vertical line representing the gas INLET CHECK VALVE ASSY, HDGB CHECK VALVE ASSY, OUTLET, H-DRIVE supply pressure available LABEL, TORQUE INSTRUCTIONS, H-DRIVE 3. Where both lines cross will give the LABEL, NAME PLATE, H-DRIVE approx. cycling speed of the H-Drive SOCKET CAP SCREW WASHER, 5/8" BOLT, 1.312parameters of H-Drive For full operating OD, STEEL, ZINC PLATED WASHER, PRESSURE SEAL conditions including running at particular WASHER, HYTORC, STEEL, BLACK OXIDE, 24MM BOLT the hydraulic power supply required, contact NUT, STEEL, GRADE 8, ZINC PLATE, M24X3, 19MM LONG factory or distributor with following data:

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.