This document presents technical information on the Electronic Pressure (EP) Compensation Control designed for PVX Series Variable Displacement Pumps. The control system enables remote-controlled, pressure-compensated performance, optimizing pump output flow relative to pressure demands.
The control system modulates pump output flow as a percentage relative to system pressure, maintaining consistent performance across varying pressures. Response curves illustrate the relationship between regulated pressure and input current for both 12 VDC and 24 VDC inputs, demonstrating precise pressure control within specified ranges.
Graphs included in the document depict:
Manufacturer: Hartmann Controls
Address: 604 Progress Drive, Hartland, WI 53029, USA
Phone: (262) 367-4299
Fax: (262) 367-5645
Website: www.hartmanncontrols.com
Email: [email protected]
PUMPS - MOTORS - CONTROLS EP, Electronic Pressure Compensation Control for PYX Series Pumps 604 PROGRESS DRIVE, HARTLAND, WI 53029
Open the catalog to page 1PROPORTIONAL PRESSURE SYSTEM TITLE: THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF HARTMANN CONTROLS INC., AND IS NOT TO BE USED IN A MANNER DETRIMENTAL TO HARTMANN CONTROLS INC. SCMEP ELECTRONIC PRESSURE COMPENSATOR 604 PROGRESS DRIVE HARTLAND, Wl 53029
Open the catalog to page 2THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF HARTMANN CONTROLS INC., AND IS NOT TO BE USED IN A MANNER DETRIMENTAL TO HARTMANN CONTROLS INC. EPPUMP TITLE:PVX PUMP WITH AN ELECTRONIC PRESSURE COMPENSATION CONTROL
Open the catalog to page 3NOT TO SCALE TITLE: THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF HARTMANN CONTROLS INC., AND IS NOT TO BE USED IN A MANNER DETRIMENTAL TO HARTMANN CONTROLS INC. OUTLINE OF AN ELECTRONIC PRESSURE COMPENSATION CONTROL DWG NO: 53308DIM
Open the catalog to page 4POWER INPUT TERMINALS SAE #4 O-RING, COMMAND SIGNAL INPUT PORT THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF HARTMANN CONTROLS INC., AND IS NOT TO BE USED IN A MANNER DETRIMENTAL TO HARTMANN CONTROLS INC. LAYOUT OF AN ELECTRONIC PRESSURE COMPENSATION CONTROL
Open the catalog to page 5RESPONSE CURVES OF ELECTRONIC PRESSURE COMPENSATION CONTROL IN SELECT PRESSURE RANGES; ISO 32 OIL @ 115 o F INPUT CURRENT @ 12 VDC (Amps) 0 REGULATED PRESSURE (bars)
Open the catalog to page 7ELECTRONIC PRESSURE COMPENSATION CONTROL BIAS SETTING ADJUSTMENT 1. ENERGIZE POWER INPUT TERMINALS AND REDUCE AMPERAGE TO THE MINIMUM SHOWN ON THE EP CHART 2. REMOVE ACORN NUT EROM THE REMOTE COMPENSATOR. INSERT ALEN WRENCH INTO SCREW HEAD. 3. HOLDING THE WRENCH TIGHT UNLOCK THE JAM NUT. 4. DEAD-HEAD PUMP WHILE WATCHING THE PRESSURE GAUGE AND GENTLY ADJUST BIAS SPRING TESSION: A. CLOCKWISE TURN INCREASES PRESSURE SETTING B. COUNTER-CLOCKWISE TURN DECREASES PRESSURE SETTING 5. SET BIAS SPRING TENSION ACCORDING TO THE EP-RC COMPENSATION CHART. LOCK JAM NUT. 6. COVER THE SCREW WITH ACORN NUT AND...
Open the catalog to page 84 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
7 Pages
7 Pages
7 Pages
6 Pages
4 Pages
6 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
19 Pages
18 Pages
24 Pages
14 Pages
20 Pages
15 Pages
15 Pages