Description: The HK12 is a state-of-the-art NIR (Near-Infrared) laboratory measurement device designed to measure organic components in liquids of varying consistencies. It allows simultaneous measurement of components such as fat, protein, lactose, and water with a single test. The device is compact, lightweight, and suitable for laboratory use, featuring easy sample preparation and calibration functions.
Operating Software: The HK-particuLAB Liquid software enables the measurement of up to 10 organic components and the calculation of 5 additional components. Results can be displayed individually or in a list, and are stored in a CSV file for further analysis. A performance test with a reference cuvette ensures device accuracy.
Technical Features: The HK12 uses an NIR Diode-Array detector with thermoelectric cooling for optimal signal-to-noise ratio. It employs a halogen lamp for irradiation, and the resulting diffuse reflection is analyzed by the spectrometer. The device is designed without moving optical parts, reducing maintenance needs.
Advantages: Key benefits include advanced NIR technology, no moving optical parts, no need for expensive cleaning agents, CSV file archiving, lightweight design (6 kg), user-friendly software, and the ability to expand or create new calibrations independently. It provides fast results (approx. 20 seconds) and can connect to existing laboratory PCs.
PC Requirements: A minimum of 300 MHz clock speed (Pentium III or faster), Windows 7 or higher, 512 MB RAM, and a USB interface are required.
Scope of Supply: The HK12 comes with software, cables, and is ready to connect to a PC or laptop. Training is provided upon commissioning.
Technical Data: The device features an ABS plastic/aluminum housing, dimensions of 190 x 310 x 270 mm, and weighs approximately 6 kg. It operates at 100-240 V/AC, 50/60 Hz, with a maximum of 200mA. The environmental temperature range is -20°C to +30°C. It includes a 4-in membrane keypad, a 2x24 sign LCD with LED backlight, and a USB PC interface. Analysis time is approximately 20 seconds, with sample temperatures of +40°C ±2°C for dairy products.
Directives: The HK12 complies with CE directives, including EMC directives 2014/30/EU, low-voltage directives 2014/35/EU, and RoHS directives 2011/65/EU.
See more

Catalog excerpts

HK12-1

^^TharrFr^^_KASS£N Harrer & Kassen GmbH Am Heschen 4 - 6 D - 75328 Schomberg - Langenbrand Tel.: +49 (0)7084/9248-0 Fax: +49 (0)7084/9248-29 www.harrerkassen.com [email protected]

 Open the catalog to page 1
HK12-2

Description: The HK12 is an NIR- (Near- Infrared) laboratory measurement device with state- of- the- art technology. Which can measure all organic components in liquids of different consistencies. With only one measurement you can measure simultaneously all valuable components like fat, protein, lactose, water, etc. Through the simple sample preparation, the light and compact construction of the HK12, it is ideally suitable for laboratory operation. With the easy to use calibration function, our customer can take spectra’s at the device and read the internal stored spectra with the calibration...

 Open the catalog to page 2
HK12-3

No moving parts in the optic: The Harrer & Kassen GmbH uses in his laboratory measurement devices an NIR (Near- Infrared) Diode- Array detector (Spectrometer) with thermoelectri-cally cooling, this is necessary for an optimum Signal-to-Noise ration, even under rugged application conditions. The product will be irradiated with a special developed Halogen lamp. The resulting diffuse reflection (the diffuse reflection contains the necessary information of the constituents) is transmitted via a fibre optic to the spectrometer. The spectrometer split the spectra in 256 support points. Through the...

 Open the catalog to page 3
HK12-4

Analysis time: approx. 20 sec. (adjustable) Sample temperature: Measuring equipment: Sample volumes: Cleaning: +40°C ±2°C for dairy products other products like product temperature Quartz glass cuvettes Typ:6030- OG or one way cuvettes approx. 3ml only quartz glass cuvettes PC- requirement: • 300 MHz clock speed (at least) rec ommended Pentium III- Processor (or faster) • Windows 7 (32 und 64 Bit) or higher • 512 MB RAM (or higher) • USB interface Reference measurement:Reference cuvette Technical data: Housing: Size: Weight: Protection Type: Power supply: Environmental temperature: Operation: Display: PC-...

 Open the catalog to page 4

All Harrer & Kassen catalogs and technical brochures

  1. HK11

    3  Pages

  2. particuLAB

    4  Pages

  3. HK9

    4  Pages

  4. HK8 HK8-Mini

    4  Pages

  5. HK7

    4  Pages

  6. HK6 Series

    4  Pages

  7. HK4

    4  Pages

  8. HK3 HK3-Mini

    4  Pages

  9. HK2

    4  Pages

  10. HK1 Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.