SELECTION GUIDE - 1

SELECTION GUIDE Load Sensors • Load Points • Bench Scales Floor Scales • Summing Cards • Junction Boxes • Cable

Open the catalog to page 1
SELECTION GUIDE - 2

ANATOMY OF A HARDY LOAD SENSOR * Blind Loading Hole • same precise location, • eliminating unwanted m eccentric loads common . with threaded hole designs. * Hermetically Sealed & .A nitrogen filled sensing area m laser sealed by a welded sleeve and cable entry through a glass * to metal header blocks moisture and protects circuits from ^corrosion for long sensor life, .even in harsh environments. Each sensor produced is corner adjustments (trim hopper scales. Provide additional Combined Error More consistent weight measurements, lower shock and pulsed loads. Each sensor is shipped with...

Open the catalog to page 2
SELECTION GUIDE - 3

ADVANTAGE ® LINE - Attention to Detail C2®, Second Generation Calibration Allows fast, accurate system calibration without test weights. On-board Certs The performance characteristics of each sensor are stored in an internal memory so you never lose the original certification data. Standard ¼ NPT Conduit Adapter Allows conduit to be installed right to the load sensor, increasing system reliability. Potted Cable Enclosure Proprietary material prevents moisture from contacting header terminals and wicks up cable approximately 6" providing added moisture barrier. All load cells look the same...

Open the catalog to page 3
SELECTION GUIDE - 4

ANATOMY OF A HARDY LOAD POINT Top Plate Hole Layout matches base for easy installation Bumper Plates Limit movement in one direction Adjustable Lift-off Protection Stainless Steel Plate Extra smooth, provides a low friction sliding surface Teflon Coated Load Pin For low friction Gaskets Keep dirt out Mounts available in both stainless steel or galvanized steel * Base Slotted To accept anti-lift off device Base Hole Pattern Allows 360° mounting in 90° increments Ground Strap Protects sensor from stray currents *Shown in clear plastic for illustrative purpose only. All information and...

Open the catalog to page 4
SELECTION GUIDE - 5

The HARDY C2® Difference • FAST Calibrates with ONE reference point, not FIVE • SAFE Eliminates need for full-scale test weights • RELIABLE Data stored in chip Since 1994, thousands of weighing systems have been calibrated electronically using C2® Electronic Calibration by Hardy Process Solutions. Unlike calibration with test weights, all the live weight on the scale does not have to be removed and heavy test weights do not have to be repeatedly put on and off the scale. As soon as your scale system is installed, it can be C2 calibrated, and proper scale installation verified. The result is...

Open the catalog to page 5
SELECTION GUIDE - 6

SELECTING SINGLE LOAD POINTS SINGLE LP CAPACITY SINGLE PT. lbs 5 - 16.5 REFER TO PAGE 8 FOR SPECIFICATIONS REFER TO PAGE 10 FOR SPECIFICATIONS MID CAP . REFER TO PAGE 12 FOR SPECIFICATIONS REFER TO PAGE 14-16 FOR SPECIFICATIONS REFER TO PAGE 18 FOR SPECIFICATIONS 1126 - 2.25K REFER TO PAGE 20 FOR SPECIFICATIONS Hardy’s ADVANTAGE® Line load point assemblies are designed to provide exceptional performance in a safe and predictable manner. The load point consists of a precision, C2® load sensor assembled with matched mounting hardware. Each load point comes with an installation and maintenance...

Open the catalog to page 6
SELECTION GUIDE - 7

SELECTING LOAD POINT SYSTEMS System Selection You can also determine the load point system required by calculating the system total load. The system will contain the appropriate load points for your system ordered under one number. The environment where the load point is to function may be a factor in selection. For example, the Advantage load sensors are designed to operate at temperatures of 175°F to -40°F; for higher temperature, special load sensors are available. Advantage sensors are hermetically sealed in the gauge area and at the cable entry allowing them to be classified at IP68....

Open the catalog to page 7
SELECTION GUIDE - 8

SINGLE POINT SERIES HI SP1 and SP6 Single Point Load Sensors The Hardy Process Solutions HI SP Series of single point load cells are designed for the OEM, conveyor and bench scale markets which require a low sensitivity to off center loads. They are built to perform in harsh environments found in the food, chemical and allied industries. The sensors are 17-4 PH stainless steel, with C2® calibration capabilities and come with three meters (9-10 ft) of cable. The HI SP1 is available in capacities from 7.5kg to 200kg (16.5 to 440lbs), are environmentally protected with a plastic covering to...

Open the catalog to page 8
SELECTION GUIDE - 9

SP1 Single Point Outline C2 WIRE COLOR CODE FLAG LABEL IS FOUND APPROX. 10 IN. FROM END OF SENSOR'S CABLE CABLE LENGTH 9-10 FEET SP6 Single Point Outline

Open the catalog to page 9
SELECTION GUIDE - 10

ADVANTAGE LINE - LOW CAPACIT Y HI LPB Hermetic Load Point Assembly Compression The Hardy HI LPB ADVANTAGE® Series, sliding load point system is designed for use on light to medium capacity vessels. Each load point consists of mounting hardware and a stainless steel mV/V and mV/V/ohm matched load sensor with true hermetic sealing, C2® Electronic Calibration capabilities, onboard electronic certs, a ¼ NPT conduit adapter and ten feet of cable. Each pre-assembled, low profile load point system provides lift off protection and consists of three mount types specifically designed to eliminate the...

Open the catalog to page 10
SELECTION GUIDE - 11

ADVANTAGE Load Point Outline B A (SQUARE) Ground Strap INSTALLED ON SITE TYPICAL INSTALLATION VESSEL MOUNTING TEMPLATE C2 WIRE COLOR CODE FLAG LABEL IS FOUND APPROX. 10 IN. FROM END OF SENSOR’S CABLE EXCITATION + Fixed Loading Pin Module (F) Free Sliding Module (S) DIMENSIONS- INCHES & [mm] CAPACITY LBS [kg;kN] 44, [20] WARNING: NEVER cut load sensor cable ADVANTAGE Load Sensor Outline CABLE LENGTH 10 FEET HI BBH06 Series EDGE OF MOUNTING PLATE 0.984[25.0]

Open the catalog to page 11
SELECTION GUIDE - 12

ADVANTAGE LINE - MEDIUM CAPACIT Y HI HLPS Hermetic Load Point Assembly Compression The Hardy HI HLPS ADVANTAGE® Series, sliding load point system is designed for use on medium to high capacity vessels. Each load point consists of mounting hardware and a stainless steel mV/V and mV/V/ohm matched load sensor with true hermetic sealing, C2® Electronic Calibration capabilities, onboard electronic certs, a ¼ NPT conduit adapter and twenty feet of cable. Each pre-assembled, low profile load point system provides lift off protection and consists of three mount types specifically designed to...