HS-173I Three AC outputs via PUR cable with Protective Conduit - 1

Three AC outputs via PUR cable with Protective Conduit • Intrinsically Safe with European, USA and Australian approvals • Output via three axies • For use with data collector • Protective Conduit Building services, Pulp and Paper, Mining, Metals, Utilities, Automotive, Water, Pharmaceutical Technical Performance Mounted Base Resonance Sensitivity Frequency Response Isolation Range Transverse Sensitivity see ‘How To Order’ table (nominal) see: ‘How To Order’ table ±10% Nominal 80Hz at 72°F per axies 120cpm (2Hz) to 600kcpm (10kHz) ± 5% 90cpm (1.5Hz) to 720kcpm (12kHz) ± 10% 48cpm (0.8Hz) to 900kcpm (15kHz) ± 3dB Base isolated see: ‘How To Order’ table Less than 5% 0.1mg max 0.5mA to 8mA 10 - 12 Volts DC 1 second 200 Ohms max. Ohms at 500 Volts Case Material Sensing Element/Construction Mounting Torque Mounting Bolt Provided Weight Maximum Cable Length Standard Cable Length Screened Cable Mounting Threads Submersible Depth Stainless Steel PZT/Shear 5.9ft. lbs see: ‘How To Order’ table x 1.2in long 8.3 oz. (nominal) - Stainless Steel See certificate 16 ft. PUR - length to be specified with order see: ‘How To Order’ table 328 ft. max (10 bar) Electrical Noise Current Range Bias Voltage Settling Time Output Impedance Case Isolation Sensitivity Change % HS-173I Premium ATEX Triaxial Accelerometer Operating Temperature Range Sealing Maximum Shock EMC see: attached certification details IP68 5000g EN61326-1:2013 Applications Fans, Motors, Pumps, Compressors, Centrifuges, Conveyors, Air Handlers, Gearboxes, Rolls, Dryers, Presses, Cooling, VAC, Spindles, Machine Tooling, Process Equipment Vibration sensor should be firmly fixed to a flat surface (spot face surface may be needed to be produced and cable anchored to sensor body.) E This product is certified in accordance with UL 60079-0, 6th Ed, Rev. July 26, 2013 UL 60079-11, 6th Ed. Rev. September 6, 2013 CAN/CSA C22.2 No. 60079-0:15 Rev. October 2015 CAN/CSA C22.2 No. 60079-11:14 UL 913, 8th Ed. Rev. October 16, 2015 www.hansfordsensors.com sales@hansfordsensors.com We reserve the right to alter the specification of this product

Open the catalog to page 1
HS-173I Three AC outputs via PUR cable with Protective Conduit - 2

HS-173I Premium ATEX Triaxial Accelerometer Three AC outputs via PUR cable with Protective Conduit Intrinsically Safe Requirements IECExBAS 18.0082X Baseefa18ATEX0130X II 1GD Ex ia II T6..T4 Ex ia IIIC T135ºC Da Ex ia IIIB T102ºC…T131ºC Da Certificate details: Group I Certified Temperature Range Certificate details: Group II and III Australia Approval Group I Terminal Parameters 10m of cable Certificate No. SGSNA/19/BAS/00005 Cl I, II, III, Div 1, 2 Gr A-G T* Cl I Zn 0 AEx ia IIC T6…T4 Ga Cl II Zn 20 AEx ia IIIC T135ºC Da Ex ia IIC T6...T4 Ga Ex ia IIIC T135ºC Da Terminal Parameters 92m of...

Open the catalog to page 2

All Hansford Sensors catalogs and technical brochures

  1. HS-AA031

    1 Pages

  2. HS-661

    1 Pages

  3. HS-660

    1 Pages

  4. HS-AA Series

    1 Pages

  5. HS-JE Series

    1 Pages

  6. hs-sr

    1 Pages

  7. H S - S C

    1 Pages

  8. HS - SE

    1 Pages

Archived catalogs