Hansen P4Hansen M4ACC

Hansen P4Hansen M4ACC
1 / 136 PagesView full catalog

Hansen P4Hansen M4ACC

Product catalog summary
Overview: Hansen Industrial Transmissions offers robust gear units specifically designed for cooling towers and air-cooled condensers. These units are engineered to withstand demanding operating conditions using standard components and are ISO 9001 certified, ensuring high quality and reliability. They are supported by a global network of service centers.
Specifications: Hansen provides flexible gear units that can be customized to meet specific industry requirements. Key products include the Hansen M4 ACC Helical Gear Unit and the Hansen P4 Bevel Helical Gear Unit. The M4 ACC is designed for air-cooled steam condensation plants, featuring optimized gear geometry for reduced noise and a monobloc design for increased housing stiffness. The P4 unit is tailored for vertical housings in cooling towers, with an extended bearing span for enhanced dynamic stability and reduced vibrations.
Key Features: Hansen gear units offer high-quality carburised and ground gearing for strength and low noise, large overhung load capacity, and a variety of bearing configurations. They ensure continuous oil circulation for extended bearing life and feature unique Oil-Lock™ and Oil-Guard™ systems for maintenance-free sealing. Greased labyrinth seals prevent moisture ingress.
Procedures and Standards: The gear units comply with CTI-111 specifications and are designed according to AGMA and ISO standards. They include lubrication systems with mineral oils and EP-additives, and thermal checks are available for different operational conditions.
Optional Features: Optional features include backstops to prevent windmilling, filters with pressure relief valves, electrical heaters for low-temperature start-up, and oil level and pressure switches for monitoring.
Maintenance and Protection: Standard protection systems include a painting system suitable for atmospheric-corrosivity category C4 (L). Units are shipped without oil but with factory-filled grease lubrication points. Inspection and protection measures are in place for shipping conditions.
Applications: These gear units are suitable for both wet and dry cooling tower environments, with specific adaptations for low operating speeds and windmilling conditions. They are ideal for environments where water resources are scarce.
Advantages: Hansen's solutions offer proven reliability under severe conditions, cost-effective customization, and comprehensive engineering support. The design facilitates easy inspection and servicing, reducing downtime significantly.
Conclusion: Hansen Transmissions provides complete drive package solutions for cooling towers, focusing on reducing downtime and enhancing operational efficiency through innovative design and global service capabilities.
See more

Catalog excerpts

Hansen P4Hansen M4ACC-1

Powerful solutions for cooling towers and air cooled condensers Solutions performantes pour aéroréfrigérants et condensateurs à air Leistungsstarke Lösungen für Kühltürme und Luftkondensatoren Potentes soluciones para torres de refrigeración y condensadores de aire

 Open the catalog to page 1
Hansen P4Hansen M4ACC-2

COMPLETE AND POWERFUL C O M PP L E T E A N D PP O W E R F U L COM LETE AND OWERFUL COM LETE AND OWERFUL C O M PP L E T E A N D PP O W E R F U L SS O L U T I O N S FF O R OLUTIONS OR SOLUTIONS FOR SSOLL U LIEE NESAF O RPP O W E R F U L U R COO PPN GT SOF O DR SS O M TT I O N A N D CO MLL ILOGETT O NEE R O W E R F U L T W COOLING TOWERS OI N W CO O I I O O W R O W CO LL LLTN GNT OF OE R S SSO O UI N GNTS F OER S UTIO S R COO ING OWERS C O O LL I N G TT O W E R S COM LETE AND OWERFUL C O M PP L E T E A N D PP O W E R F U L Because TofO Nsevere Rdemandsplaced S O L U Iof the severe R Because O N...

 Open the catalog to page 2
Hansen P4Hansen M4ACC-3

SECTION A - SECTION A - TEIL A - SECCIÓN A Air cooled condenser drives Contents Commande des ventilateurs des condensateurs à air Index Antriebsgruppen für Luftkondensatoren Inhaltverzeichnis Las transmisiones del ventilador de los condensadores de aire Índice SECTION B - SECTION B - TEIL B - SECCIÓN B Cooling tower drives Contents Commande des ventilateurs pour aéroréfrigérants Index Antriebsgruppen für Kühltürme Inhaltverzeichnis Las transmisiones del ventilador para torres de refrigeración Índice

 Open the catalog to page 3
Hansen P4Hansen M4ACC-5

AIR COOLED CONDENSER DRIVES AIR COOLED CONDENSER DRIVES Hansen M4 ACC standardized gear units Programme - Selection Description Selection Request for quotation Accessories and options Rating tables Mechanical power ratings and rated thrust load Exact ratio's iex and moments of inertia J Thermal power ratings Dimensional drawings Hansen M4 ACC gear units without oil filter Hansen M4 ACC gear units with oil filter Hansen P4 standardized gear units Programme - Selection Description Selection Request for quotation Accessories and options Rating tables Mechanical power ratings and rated thrust load...

 Open the catalog to page 5
Hansen P4Hansen M4ACC-7

PROGRAMME - SELECTION STANDARDISED GEAR UNITS FOR AIR COOLED CONDENSER DRIVES Standardised gear units for Air Cooled Condenser Drives PROGRAMME - SELECTION Motor Power

 Open the catalog to page 7
Hansen P4Hansen M4ACC-8

HANSEN M4 ACC GEAR UNITS Hansen M4 ACC gear units for Air Cooled Condenser Drives FOR AIR COOLED CONDENSER DRIVES P : Hansen M4 V : vertical low speed shaft P : parallel shafts Size : DA-> FX number of stages: 2 Ratio 10 : nominal ratio of the gear unit Drive package 11 : K: lantern drive package Motor 12 : motor size and number of poles Shaft arrangement 7 : high speed shaft extension : U : up 8 : low speed shaft extension : D : down 9 : low speed shaft type : N : normal solid shaft The gear unit Units are designed to comply with the standard CTI-111 specifications for gear units. The mechanical...

 Open the catalog to page 8
Hansen P4Hansen M4ACC-9

HANSEN M4 ACC GEAR UNITS FOR AIR COOLED CONDENSER DRIVES The gear units are to be fitted with standard flange mounted IEC motors (type B5). For more information on motors, refer to motor catalogues. For Nema motors, refer to us. Use of two speed motors: when changing speed with two speed motors, the motor has to be slowed down below the low speed, be- Standard protection systems • As a standard, Hansen M4 ACC gear units are provided with a painting system that is suitable to be applied in the atmosphericcorrosivity category “C4 (L)” according to ISO 12944-2 (and ISO 12944-5). The choice of colour...

 Open the catalog to page 9
Hansen P4Hansen M4ACC-10

Mechanical power rating Mechanical power rating / Air Cooled Condenser Drives AIR COOLED CONDENSER DRIVES Reference Data SELECTION DATA refer to page A7 Mechanical power rating P Start-up torque TS Check if Mechanical torque of the gear unit (kNm) Design total start-up time @ 1500 min-1 (hrs) (tS @ 1500) Design total start-up time @ 1500 min-1 refers to the total start-up time over the design lifetime of the gear unit, taking into account: - number of start-ups - duration of a single start-up - input speed equal to 1500 min-1 Note: make sure that Ts, T and n refer to the same shaft (speed); Total...

 Open the catalog to page 10
Hansen P4Hansen M4ACC-11

SELECTION Thermal power rating Thermal power rating / Air Cooled Condenser Drives AIR COOLED CONDENSER DRIVES Reference Data Thermal check Ptn for gear unit without forced cooling No forced cooling required Ptf for gear unit with 1 fan factor a for ambient temperature without forced cooling Reduction factor b for duration of service h/year factor c for air circulation (without fan) Mounting Indoors- small enclosure Indoors- normal working areas Outdoors- protected against sun Air flow to be selected according to the structure: Open structure: gear units installed in an open steel frame structure...

 Open the catalog to page 11
Hansen P4Hansen M4ACC-12

AIR COOLED CONDENSER DRIVES Air Cooled Condenser Drives Ref : Motor power Absorbed power Absorbed torque Running time in h/day Peak torque in excess of 200% Ta Number of starts/stops per 10 hours : Selection of corrosion category: tick where appropriate tick where appropriate Corrosion category according to ISO 12944-2 High speed shaft (HSS) Constant speed(s) Variable speed Constant speed(s) Variable speed tick where appropriate Corrosion category according to ISO 12944-2 Parallel shafts Not allowed 4. THRUST LOAD ON LOW SPEED SHAFT Aerodynamic thrust load away from gear unit Mandatory (minimum...

 Open the catalog to page 12
Hansen P4Hansen M4ACC-13

Sketch of application TOP VIEW

 Open the catalog to page 13
Hansen P4Hansen M4ACC-15

COMMANDE DES VENTILATEURS DES CONDENSATEURS A AIR COMMANDE DES VENTILATEURS DES CONDENSATEURS A AIR Réducteurs standard Hansen M4 ACC Programme - Sélection Description Sélection Demande d'offre Accessoires et options Tables de sélection Puissances mécaniques nominales et charge axiale nominale Rapports de réduction exacts iex et moments d'inertie J Puissances thermiques nominales Plans d'encombrement Réducteurs Hansen M4 ACC sans filtre d'huile Réducteurs Hansen M4 ACC avec filtre d'huile Réducteurs standard Hansen P4 Programme - Sélection Description Sélection Demande d'offre Accessoires et...

 Open the catalog to page 15

All Hansen Industrial Transmissions catalogs and technical brochures

  1. FINE CYCLO

    170  Pages

  2. SERVO 6000

    38  Pages

  3. Paramax 9000

    281  Pages

  4. Bevel Buddybox 4

    248  Pages

  5. Altax Neo

    39  Pages

  6. catalogue

    11  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.