Technical Specifications:- Supply Voltage: Single-phase 100–230 V AC ±10%, Three-phase 400 V
- Stroke: Customizable upon request
- Protection System: IP 55, IP 66
- Protection Class: Class 1 or 2
- Duty Cycle: S3–12% ED, 35s 'on', 300s 'off'
- Operation System: Electric, pneumatic, low voltage via control box
- End Position: Limit switches (microswitch)
- Electronic Position Control: Analogous distance control (0–10 V, 0–20 mA)
- Security Option: Declutching system
Control Box:- Operates up to four linear actuators
- Includes low voltage handset
Performance Data:- Force: 10000–2000 N
- Frequency: 50 Hz, 60 Hz
- Speed: 3.5–63.0 mm/s at 50 Hz, 4.2–75.0 mm/s at 60 Hz
Note: Fixing dimension is load dependent.