Industrial Motors
28Pages

{{requestButtons}}

Catalog excerpts

Industrial Motors - 1

INDUSTRIAL MOTORS

Open the catalog to page 1
Industrial Motors - 2

moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for almost every industrial application in many different branches of industry. Innovative products and our sound technical competence have made us a reliable partner for more than 50 years. We understand our customers’ problems and find individual solutions.

Open the catalog to page 2
Industrial Motors - 3

ideas moving ideas – With this slogan we present ourselves on the market. It encapsulates our aim to develop and produce modern and economic drive solutions for our customers. Our experience and orientation towards the future provide the foundations for our ambitious strategies. From our manufacturing site in Germany as well as our international sales offices we deliver HANNING products and service to successful companies all over the world. Industrial motors Industrial motors Wherever motors need to be individually adapted to production processes – HANNING industrial motors available from...

Open the catalog to page 3
Industrial Motors - 4

Industrial motors Modern production sites need intelligent drive components. These drives must be equipped with the latest technology and standards. Furthermore it must be ensured that they can be flexibly integrated into the customer’s drive system. HANNING industrial motors meet all these requirements and are suitable for worldwide application. HANNING is specialised in individual drive components and systems. We analyse our customers’ requirements, design and manufacture the corresponding drive components and integrate the new drive solution into the customer’s already existing...

Open the catalog to page 4
Industrial Motors - 5

Modular design The following diagram shows the versatile equipment options for HANNING industrial motors: Special housing profiles Windings • Customer-specific winding design • Specially protected winding • Insulation class F or H • Thermal winding protection Electrics • Different connections • Operating elements • DriveSAS electronic centrifugal switch for single-phase asynchronous motor • Specific electronics • Cable connection without terminal box • Special shafts • A-side fixed bearings • Special bearings • Radial shaft seal • No fan • Separate fan • Centrifugal mass fan • Brakes •...

Open the catalog to page 5
Industrial Motors - 6

Electrical design Power The rated powers listed in the table below apply to continuous operation – S1 – according to EN 60034 Part 1 at a frequency of 50 Hz, a coolant temperature (CT) of max. 40 °C and an installation height of up to 1000 m above see level. The rated values refer to the power at the shaft end of the motor. CT [°C] Permissible power in % of rated power Installation height above see level in [m] Permissible power in % of rated power If the highest possible coolant temperature above 1000 m is lower by 8 °C per 1000 m, it is not necessary to derate the power. With different...

Open the catalog to page 6
Industrial Motors - 7

Electrical design Inverter operation All industrial motors are suitable for inverter operation. Please contact HANNING for the corresponding design information. Pole-changing motors Basis-Leistungsteile der Frequenzumrichter-Reihe DriveCCI Motor winding Circuit Number of poles Synchronous speed Dahlander circuit Pole-changing motors are usually used with one operating voltage and direct switch-on. Motors running at three or four speeds and speeds which do not meet the 1:2 ratio, have two separate windings (see table). They are connected in Y circuits.

Open the catalog to page 7
Industrial Motors - 8

Electrical design – DriveSAS DriveSAS electronic centrifugal switch for single-phase asynchronous motors Single-phase asynchronous motors have low breakaway torques. For some applications these torques are not high enough to accelerate the motor to its operating speed. This is where the DriveSAS electronic centrifugal switch is used. It ensures a reliable and safe start of a motor. Starting capacitors are switched depending on speed or time and ensure stable operation even if the load and/or mains conditions vary. Unfavourable environmental conditions do not exist for the DriveSAS...

Open the catalog to page 8
Industrial Motors - 9

Mechanical design Type of protection As standard all motors are delivered in IP 54. They are however also available with a higher protection. Designs according to DIN EN 50347 Design With feet 2 end shields, housing with feet, free shaft end, installation on base 2 end shields, housing without feet, free shaft end, FF flange near bearing on drive end, flange connection With feet and FF flange 2 end shields, housing with feet, free shaft end, FF mounting flange near bearing on drive end, installation on base for flange connection 2 end shields, housing without feet, free shaft end, FT...

Open the catalog to page 9
Industrial Motors - 10

Mechanical design Maximum axial load The shaft ends and the diameters of the centering shoulder listed in the table below comply with the following fits. Bores in couplings and pulleys must have at least one fit according to ISO-H7. If the maximum radial load Fr is applied, an axial load of Fa=0.3 x Fr is permissible. Tolerances The following tolerances apply to the sizes A, B, M and H indicated in the table. Keyways and keys (F and GA) correspond to DIN 6885. Tolerances Size Shaft ends Center holes 60° according to DIN 332. Threads for press on and pull off device. Shaft ends Shaft...

Open the catalog to page 10
Industrial Motors - 11

Mechanical design Permissible radial load Frame size Permissible radial load Fr [N] Balancing The rotors are dynamically balanced with half key at the shaft end. The standard motor design comply with the vibration severity level N to ISO 2373. Optionally HANNING industrial motors are also available in vibration severity level R.

Open the catalog to page 11
Industrial Motors - 12

Technical data 3-phase industrial motors Three-phase AC motors at 400 V, 50 Hz Rated power Frame size Rated speed Rated current Efficiency class Rated torque Rel. starting torque MA/MN Rel. stalling torque MK/MN Rel. starting current IA/IN Basis-Leistungsteile der Frequenzumrichter-Reihe DriveCCI 1500 rpm in no-load operation 0.06 0.09 Basis-Leistungsteile der Frequenzumrichter-Reihe DriveCCI 1000 rpm in no-load operation 0.12 1) Frame size not according to IEC standard * Frame size 63 K = mounting dimensions as frame size 63, total length shorter (k) with flange motors only ** Frame size...