Overview: The Hannibal Static Frequency Converters (FCS series) are high-performance devices using on-line double conversion technology to ensure reliable and high-quality power supply. They are designed for energy and cost efficiency, suitable for environments like data centers and IT networks.
General Specifications: The FCS series features DSP control, 3-level technology, and a fully digital structure. It offers low input current harmonic distortion (THDI), high input power factor, and efficiency up to 95%. The converters provide selectable input/output frequency ranges and advanced control and protection mechanisms, with communication options like RS232, SNMP, and MODBUS.
Models and Options: Models range from 10 to 250 kVA with frequency options of 50Hz, 60Hz, and 400Hz. They offer various display options, alarm logging, and communication interfaces. Optional features include external transformers and additional dry contacts.
Input and Output Specifications: Input voltages are 220/380VAC with a frequency tolerance of ±10%, maintaining a power factor of ≥0.99 and THDI ≤3%. Output specifications include a power factor of 1.0, voltage THD ≤3%, and efficiency up to 96%, with advanced protections.
Standards and Compliance: The FCS series complies with EN62040-1, EN62040-2, and EN62040-3 standards, and is ISO9001 and ISO14001 certified.
Environmental and Physical Characteristics: Operating temperature is 0ºC to +40ºC, storage is -15ºC to +45ºC, with a protection degree of IP20. They operate at altitudes up to 3000m with derating, and noise levels are below 71 dBA.
Additional Features: Includes advanced self-diagnostics, maintenance indicators, and a comprehensive alarm logging system. User interfaces include LCD panels and LED diagrams for monitoring and control.
Specifications: Power ratings are 75 to 200 kVA, with input voltage of 220/380VAC3P+N+G and frequency of 50Hz ±10%. Protections include fuses, voltage and frequency tolerance, and input contactor.
Output: Output power ranges from 75 to 200 kW with a power factor of 1.0. Output voltage is 120/208VAC3P+N+G with a voltage THD of ≤3% for linear loads. Frequency is 400Hz ±0.2%, with an efficiency of ≥91.0% to ≥93.5%.
General Features: Complies with EN62040 standards. User interface includes LCD panel, LED diagram, and control buttons. Communication options include RS232, SNMP, Modbus, and RS485.
Environmental and Physical Characteristics: Operating temperature is 0ºC to +40ºC, storage is -15ºC to +45ºC, with a protection degree of IP20. Altitude rating is ≤1000m at 100% power, with derating above 1000m. Noise levels range from <68 dBA to <73 dBA.
Options: Optional features include different voltages, uninterruptible operation with battery, parallel operation, and different IP degrees. External transformers and communication adaptors are available.
See more

Catalog excerpts

Static Frequency Converter FCS Series-1

We will find a product or make a new one Static Frequency Converter FCS Series 10-250kVA 50Hz, 60Hz, 400Hz Industrial-Static Frequency Converter Hannibal Static Frequency Converters is a high-performance, On-line double conversion technology that provides a reliable, high-quality power supply and, at the same time, achieves significant energy and financial savings in terms of installation and operating costs. High-end design features plus great flexibility capacity (options, communications,…) make FCS series the best option to protect and secure a wide range of environments: datacenters, hosting, housing, IT-networks, server farms, voice and data networks,

 Open the catalog to page 1
Static Frequency Converter FCS Series-2

GENERAL SPECIFICATIONS Addon Options • 3-Level technology and fully digital structure (*) • Less electronic components and SMD technology • Low input current hormonic distortion (THDI) • High input power factor • Selectable input/output frequency range within 50-60Hz (For only FCS300H-60 models) • High output power factor (PF :1.0) • Advanced control and protection at input • Current limititation at output, DC leakage, short circuit and overload protection • Advanced TFT front panel (For 40kVA and above) (*) • Advanced diognostic, easy monitoring and service intervention 512 event logs (46.000...

 Open the catalog to page 2
Static Frequency Converter FCS Series-3

Frequency Converter

 Open the catalog to page 3
Static Frequency Converter FCS Series-4

FCS SERIES FCS 300H 50/60Hz Frequency Converter Voltage (ui/Ui)* Frequency** Rectifier soft start time Protections Fuses,Voltageand Frequencytolerance, Input power limit,Phase sequency indicator, Input contactor Power factor Voltage (uo/Uo)* Voltage THD Frequency** Voltage tolerance 1,0 (0,8 and 0,9 Optional) 220/380VAC3P+ N + G < 3% (linear load) ± 1% (linear load)± 5% (dynamicload) Recovery time (Dynamicload) Efficiency (@100% load input voltage tolerance ± 1,5% transformer excluded) Crest factor (@100% load) Overload capacity User interface Alarm logging Other protections Advanced short circuit,Voltagetolerance...

 Open the catalog to page 4
Static Frequency Converter FCS Series-5

FCS SERIES FCS3000X 50/60Hz Frequency Converter Voltage (ui/Ui)* Frequency** Rectifier soft start time Protections OUTPUT Power (kW) Power factor Output current rated value Voltage (uo/Uo)* VoltageTHD Frequency** Fuses,Voltageand Frequencytolerance, Input power limit,Phase sequency indicator Outputvoltage tolerance Recovery time (Dynamicload) < 50 ms Overload capacity 10 min. @125% load: 1 min. @150% load Protections Advanced short circuit,Voltagetolerance protection, DC balance, Regenerativeload, Current limitingprotections Standards User interface Indicators Advanced Communication Inputs Softwa...

 Open the catalog to page 5
Static Frequency Converter FCS Series-6

Frequency ConverterFCS 300C 50/60Hz Transformer Based Frequency Converter Model Voltage (ui/Ui)* Frequency** Rectifier soft start time Protections Fuses,Voltageand Frequencytolerance, Input power limit,Phase sequency indicator, Input contactor Power factor Voltage (uo/Uo)* Voltage THD Frequency Voltage tolerance 1,0 (0,8 and 0,9 Optional) 120/208VAC3P+ N + G < 3% (linear load) ± 1% (linear load)± 5% (dynamicload) Recovery time (Dynamicload) Output isolationtransformer Efficiency (@100% load input voltage tolerance ± 1,5% transformer included) Crest factor (@%100 load) Overload capacity User interface...

 Open the catalog to page 6
Static Frequency Converter FCS Series-7

FCS SERIES FCS 300C 50/60Hz Transformer Based Frequency Converter Voltage (ui/Ui)* Frequency** Rectifier soft start time Protections Fuses,Voltageand Frequencytolerance, Input power limit,Phase sequency indicator, Input contactor Power factor Voltage (uo/Uo)* VoltageTHD Frequency Voltage tolerance ± 1% (linear load)± 5% (dynamicload) Recovery time (Dynamicload) Output isolationtransformer Efficiency (@100% load input voltage tolerance ± 1,5% transformer included) Overload capacity User interface Alarm logging Other protections Galvanicisolation transformer integrated into the internal inverter...

 Open the catalog to page 7
Static Frequency Converter FCS Series-8

INPUT Voltage (ui/Ui)* Frequency** Fuses,Voltageand Frequencytolerance, Input power limit,Phase sequency indicator, Input contactor Power (kW) Power factor Voltage (uo/Uo)* VoltageTHD Frequency Outputvoltage tolerance Recovery time (Dynamicload) Output isolationtransformer Efficiency (@100% load input voltage tolerance ± 1,5% transformer included) Crest factor (@ 100%load) Overload capacity Internal, inverter integratedgalvanicisolationtransformer User interface Alarm relaycontacts Other protections Temperature range Protection degree* Relative humidity Altitude Acoustic noise Short circuit protection,...

 Open the catalog to page 8
Static Frequency Converter FCS Series-9

FCS SERIES FCS300T 400Hz Transformer Based Frequency Converter Voltage (ui/Ui)* Fuses,Voltageand Frequencytolerance, Input power limit,Phase sequency indicator, Input contactor Power factor Voltage (uo/Uo)* Outputvoltage tolerance ± 1% (linearload), ± 5% (dynamic load) Output isolation transformer Internal, inverter integratedgalvanic isolation transformer Crest factor (@100% load) 3:1 Overload capacity User interface Alarm relaycontacts Other protections Temperature range Protection degree* Relative humidity Altitude Acoustic noise Dimensons (mm) HxWxD OPTIONS Different input/output voltage,...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.