1. Catalogs
  2. Hanna Instruments
  3. Ion Selective Electrodes Catalog

Ion Selective Electrodes Catalog

Ion Selective Electrodes Catalog
1 / 20 PagesView full catalog

Ion Selective Electrodes Catalog

Product catalog summary
Introduction
HANNA Instruments has launched a new series of Ion Selective Electrodes (ISEs) tailored for industries such as research, agriculture, and water quality monitoring. These electrodes are complemented by ionic strength adjusters, filling solutions, and certified standards to ensure high performance and durability.
ISE Electrode Types
  • Gas Sensors: Utilize a gas permeable membrane to detect dissolved gases like ammonia and carbon dioxide.
  • Liquid Membrane Electrodes: Employ a polymer matrix with ion-exchangers for ions such as nitrate and potassium.
  • Solid State Electrodes: Constructed from compressed silver halides or crystalline material for ions like bromide and fluoride.
Reference and Combination Electrodes
Reference electrodes provide stable voltage for ISEs, while combination electrodes integrate the sensor and reference electrode, making them ideal for field measurements.
ISE Electrodes Overview
The document details specifications for various electrodes, including measurement range, pH range, temperature range, and potential applications for ions such as ammonia, bromide, cadmium, calcium, and more.
Measurement Methods
  • Direct Potentiometry: Directly measures ion concentration.
  • Incremental Methods: Involves adding known quantities of ions.
  • Potentiometric Titration: Uses titrants to determine ion concentration.
Solutions and Accessories
Includes ISE standards, gas sensor fill solutions, ionic strength adjusters, and silver-free reference fill solutions. Accessories such as replacement caps and membrane kits are also available.
Reference Chart
A comprehensive chart provides details on electrode types, filling solutions, and standards for various ions.
Specifications
The document lists a wide range of ISE standards and solutions, detailing concentrations and volumes, typically in 500 mL bottles. It also describes ionic strength adjusters and electrolyte solutions for consistent ionic strength and improved measurement accuracy.
Procedures
Outlines the use of direct potentiometry and incremental methods for ion analysis, highlighting their efficiency and error reduction capabilities. Step-by-step guidance is provided for performing these measurements, including calibration procedures.
Instruments
Describes HANNA Instruments products like the HI 98184 and HI 98185 portable ISE meters, and the HI 4222 pH/ISE bench meter, featuring waterproof protection, multiple calibration points, data logging, and USB connectivity.
Recommendations
Emphasizes the importance of using correct filling solutions and ISAs for optimal ISE performance, and recommends regular calibration and maintenance of electrodes and instruments.
Accessories
Lists various accessories, including replacement parts, membrane kits, and conditioning solutions, designed to enhance the functionality and longevity of HANNA Instruments' ISE products.
Key Features
Highlights features such as the Clip-Lock™ exchangeable burette system, graphical displays, multi-language interfaces, and real-time logging to improve user experience and measurement efficiency.
Overview of Clip-Lock™ System
Details the HANNA Clip-Lock™ system and its titration equipment, emphasizing ease of burette substitution and performing various titrations with the same titrant.
Key Features of Clip-Lock™ System
  • Allows quick exchange of reagent burettes.
  • Burette sizes available in 5 mL, 10 mL, and 25 mL, made of chemically resistant material.
  • Potentiometric titrations range from -2000.0 to 2000.0 mV, -2.000 to 20.000 pH, and -5.0 to 105.0°C.
  • High accuracy and resolution for measurements.
  • Graphic LCD display, real-time and stored graphs, and data storage for up to 100 complete reports.
  • Connectivity options include VGA display, PC-keyboard, parallel printer, and RS 232 input.
Specifications of Clip-Lock™ System
  • Burette Auto-Detection: Automatically recognizes burette size.
  • Programmable Stirrer: Propeller type with adjustable RPM.
  • Flow Rate: User-selectable from 0.1 mL/min to 2 x burette volumes/min.
  • pH Calibration: Manual or automatic at 1-5 points with various buffer sets.
  • Titration Methods: Includes acid-base, redox, precipitation, complexometric, non-aqueous, ion-selective, and argentometric titrations.
Ordering Information
Lists different models (HI 901 and HI 902) with specific voltage options, each supplied with a 25 mL glass burette, burette driver assembly, power adapter, and instructions.
Company Information
HANNA Instruments emphasizes its commitment to providing a complete range of analytical products with solid build quality, customer service, and competitive pricing since 1978.
See more

Catalog excerpts

Ion Selective Electrodes Catalog-1

Electrodes | Solutions | Instrumentation ION SELECTIVE MEASUREMENT > catalog featuring our full line of Ion Selective Electrodes size="-2">

 Open the catalog to page 1
Ion Selective Electrodes Catalog-2

HANNA instruments , Inc. Woonsocket, RI USA Dear Valued Customer,It is with great pleasure that I introduce > HANNA s new line of Ion SelectiveElectrodes. These electrodes complement our extensive offering of high performance electrochemical products. This catalog features our complete line of half-cell and combination Ion Selective Electrodes as well as meters and accessories to complete this new line.ISE technology offers considerable advantages to analyticalchemistry. Theseelectrodes are ideal in a wide range of industries such as research laboratories, agriculture, education, food processing,...

 Open the catalog to page 2
Ion Selective Electrodes Catalog-3

Overview ISEElectrode Types . . . . . . . . . . . . . . . . . . . . .4 Reference and Combination Electrodes . . . . . . . . . .5 ISE Electrodes Ammonia Bromide Cadmium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6CalciumCarbon Dioxide Chloride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7CupricCyanide Fluoride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8IodideLead/Sulfate Nitrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9PotassiumSilver/Sulfide Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Sensors...

 Open the catalog to page 3
Ion Selective Electrodes Catalog-4

HANNA s ion selective electrodes can be grouped into three general categories based upon construction. > Solid State Liquid Gas Theory: The potassium electrode wasone of the earliest liquid membrane sensors developed of this type. The membrane is usually in the form of a thin disc of PVC impregnatedwith theantibiotic valinomycin. The exchanger, also known an ionophore, is a ring structure that fits potassium ions inside like a lock and key. This type of membrane is not as rugged as the solid state type so they are designed for easy replacement of the sensing module. > areavailable as both single...

 Open the catalog to page 4
Ion Selective Electrodes Catalog-5

HANNA s reference electrode is used with our half-cell ISE sensors to provide accurate and repeatable measurements. > HANNA s combination electrodes incorporate themeasuring electrode with the reference making them ideal for field measurements. > Reference Combination are used toprovide a stable voltage and electrolytic contact to permit a voltage gradient to be measured across a measurement membrane such as an ISE. > includea sensor and reference electrode in a single electrode body. Our combination ion selective electrodes provide the same selectivity and response as our ISE half-cells, but...

 Open the catalog to page 5
Ion Selective Electrodes Catalog-6

Type Gas-Sensing;Combination Solid-state;Half-cell Solid-state;Combination Solid-state;Half-cell Solid-state;Combination > -6 -6 -6 -7 -7 Measurement Range 1M to 1X 10 M17000 to 0.02 ppm 1M to 1X 10 M79910 to 0.08 ppm 1M to 1X 10 M79910 to 0.08 ppm 1M to 1X 10 M11200 to 0.01 ppm 1M to 1X 10 M11200 to 0.01 ppm Optimum pH Range >11 2 to 12.5 2 to 12.5 2 to 12.5 2 to 12.5 Temperature Range 0 to 40C 0 to 80аC 0 to 80C 0 to 80аC 0 to 80C Approximate Slope -56 -56 -56 +28 +28 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm Body Material Delrin Epoxy PEI Epoxy...

 Open the catalog to page 6
Ion Selective Electrodes Catalog-7

Type Polymer Membrane; Half-cell Polymer Membrane;Combination Gas Sensing;Combination Solid-state;Half-cell Solid-state;Combination > -6 -6 -2 -4 -5 -5 Measurement Range 1M to 3X 10 M40080 to 0.12 ppm 1M to 3X 10 M40080 to 0.12 ppm 1X 10 M to 1X 10 M440 to 4.4 ppm 1M to 5X 10 M35000 to 1.8 ppm 1M to 5X 10 M35000 to 1.8 ppm Optimum pH Range 4 to 10 4 to 10 4.2 to 5.2 2 to 11 2 to 11 Temperature Range 0 to 40C 0 to 40аC 0 to 40C 0 to 80аC 0 to 80C Approximate Slope +28 +28 +54 -57 -57 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm Body Material PVC PEI/PVC...

 Open the catalog to page 7
Ion Selective Electrodes Catalog-8

Type Solid-state;Half-cell Solid-state;Combination Solid-state;Half-cell Solid-state;Combination Solid-state;Half-cell Solid-state;Combination > -6 -6 -2 -6 -2 -6 -6 -6 Measurement Range 0.1M to 1X 10 M6354 to 0.06 ppm 0.1M to 1X 10 M6354 to 0.06 ppm 10 M to 1X 10 M260 to 0.02 ppm 10 M to 1X 10 M260 to 0.02 ppm 1M to 1X 10 MSat. to 0.02 ppm 1M to 1X 10 MSat. to 0.02 ppm Optimum pH Range 2 to 12.5 2 to 12.5 >11 >11 5 to 8 5 to 8 Temperature Range 0 to 80C 0 to 80аC 0 to 80C 0 to 80аC 0 to 80C 0 to 80аC Approximate Slope 26 26 -57 -57 -56 -56 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Insertion...

 Open the catalog to page 8
Ion Selective Electrodes Catalog-9

Type Solid-state;Half-cell Solid-state;Combination Solid-state;Half-cell Solid-state;Combination Polymer Membrane;Half-cell Polymer Membrane;Combination > -7 -7 -6 -6 -5 -5 Measurement Range 1M to 1X 10 M127000 to 0.01 ppm 1M to 1X 10 M127000 to 0.01 ppm 0.1M to 1X 10 M20700 to 0.21 ppm 0.1M to 1X 10 M20700 to 0.21 ppm 1.0M to 1X 10 M6200 to .62 ppm 1.0M to 1X 10 M6200 to .62 ppm Optimum pH Range 2 to 13 2 to 13 4 to 7 4 to 7 3.0 to 8 3.0 to 8 Temperature Range 0 to 80C 0 to 80аC 0 to 80C 0 to 80аC 0 to 40C 0 to 40аC Approximate Slope -56 -56 +25 +25 -56 -56 Body O.D. 12 mm 12 mm 12 mm 12 mm...

 Open the catalog to page 9
Ion Selective Electrodes Catalog-10

Type Polymer Membrane; Half-cell Polymer Membrane;Combination Solid-state; Half-cell Solid-state; Combination N/A Ag > + 1.0M to 1X 10 > -6 M107900 to 0.11ppmS Ag > + 1.0M to 1X 10 > -6 M107900 to 0.11ppmS > -6 -6 Measurement Range 1M to 1X 10 M39100 to .039 ppm 1M to 1X 10 M39100 to .039 ppm > = 1.0M to 1X 10 > -7 M32100 to 0.003 ppm > = 1.0M to 1X 10 > -7 M32100 to 0.003 ppm N/A > + + Optimum pH Range 1.5 to 12.0 1.5 to 12.0 Ag 2 to 8S Ag 2 to 8S > = 12 to 14 > = 12 to 14 N/A Temperature Range 0 to 40C 0 to 40аC 0 to 80C 0 to 80аC 0 to 80C Approximate Slope +56 +56 +56 Ag > + / -28 S > = +56...

 Open the catalog to page 10
Ion Selective Electrodes Catalog-11

HI 4000-52 replacement cap HI 4001-51 membrane kit HI 4000-51 replacement pH internal and cap for AmmoniaHI 4001-45 conditioning solution HI 4000-47 4 and 7 pH with salt Ammonia Gas HI 4101 HI 4001-00 HI 4001-40 HI 4001-010.1 M HI 4001-02100 ppm HI 4001-031000 ppm Bromide Solid HI 4002 HI 4102 HI 4000-00 HI7072 HI4002-010.1 M HI 4000-70 polishing strip Cadmium Solid HI 4003 HI 4103 HI 4000-00 HI 7072 HI 4003-010.1 M HI 4000-70 polishing strip HI 4004-51 module HI 4104-51 module for combination HI4004-45 Conditioning Solution Calcium Polymermembrane HI 4004 HI 4104 HI 4004-00 HI 7082 HI 4004-010.1...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.