1. Catalogs
  2. Hanna Instruments
  3. HANNA instruments Drinking Water Catalog

HANNA instruments Drinking Water Catalog

HANNA instruments Drinking Water Catalog
1 / 36 PagesView full catalog

HANNA instruments Drinking Water Catalog

Product catalog summary
Overview
HANNA Instruments offers a comprehensive range of products for testing and monitoring drinking water, focusing on parameters such as turbidity, chlorine, pH, and ion selective electrodes (ISE). These products are designed to meet the needs of water sector professionals by providing performance, quality, and value.
Turbidity and Chlorine Meters
The HI 83414 and HI 88703 meters are designed for measuring turbidity and chlorine in drinking water. The HI 83414 measures both turbidity and free/total chlorine, while the HI 88703 is dedicated to turbidity. Both models comply with USEPA and Standard Methods, ensuring reliable and accurate readings. Key features include multiple calibration points, backlit LCD, data logging, and USB connectivity.
Turbidity Specifications
- Non-Ratio Mode: 0.00 to 40.0 NTU
- Ratio Mode: 0.00 to 4000 NTU
- Accuracy: ±2% of reading plus 0.02 NTU
- Method: Adaptation of USEPA Method 108.1 and Standard Method 2130 B
Chlorine Specifications (HI 83414 only)
- Range: 0.00 to 5.00 mg/L for both free and total chlorine
- Accuracy: ±0.02 mg/L @ 1.00 mg/L
- Method: Adaptation of USEPA Method 330.5 and Standard Method 4500-Cl G
Data Management
The Fast Tracker™ Tag Identification System simplifies data logging and management, allowing users to verify sample locations and export data for analysis. The system supports unlimited tags, each with a unique identification code.
Ordering Information
Products are available in different voltage options (115V and 230V) and come with necessary accessories such as sample cuvettes, calibration sets, silicone oil, and cleaning cloths.
Fluoride and Chloride Measurement
Public water systems often add fluoride to improve dental health, but natural deposits and industrial discharges can lead to harmful levels. The US EPA sets a maximum contaminant level (MCL) for fluoride at 4 mg/L and a secondary standard at 2 mg/L. Chloride measurement uses potentiometric titration, either manually or with an automated titrator.
Equipment and Solutions
Various electrodes and solutions are specified for accurate measurement, including HI 4010 fluoride ISE, HI 4110 combination electrode, and HI 4222 research grade meter. Solutions like HI 5004 pH 4.01 buffer and HI 70300L electrode storage solution are used for calibration and maintenance.
Specifications of HI 4222
The HI 4222 meter offers a wide range of pH, mV, and ISE measurements with high accuracy and resolution. It supports automatic calibration for pH and ISE, ensuring compliance with EPA methodologies.
HI 9126 pH Meter
This portable meter is ideal for on-site checks, featuring Calibration Check™ technology for monitoring electrode conditions. It provides accurate pH and ORP measurements with a backlit display for ease of use in various conditions.
HI 991001 and HI 991003 Meters
These redesigned, portable meters offer pH, temperature, and ORP measurements with features like Sensor Check™ for electrode status and automatic temperature compensation.
Alkalinity Measurement
The HI 84442 and HI 84431 titrators measure total titratable alkalinity using electrometric titration. They provide automatic calculations of water alkalinity, crucial for assessing water's resistance to pH changes and its corrosive capacity.
Versatile Multiparameter Titrators
The HI 901 and HI 902 titrators are designed for comprehensive water analysis, including alkalinity, hardness, and chloride. They offer flexibility in endpoint detection and automation of standard operating procedures.
Automatic Titration Systems
These systems are designed for complete analysis with the ability to determine multiple equivalence points. They come with standard methods and allow user-defined methods. Key features include Clip Lock™ quick burette change, automatic burette volume recognition, precise dosing system, and dynamic/linear dosing features.
Multiparameter Photometer (HI 83200)
This device is used for drinking water analysis, measuring over 20 parameters. It is portable, with rechargeable batteries, and can be used on-site or in the lab. Features include data logging, a light-blocking cuvette holder, and PC compatibility for data transfer and analysis.
Reagent Delivery Program
HANNA offers a monthly reagent delivery program to ensure labs have the necessary reagents for water quality tests. Reagents are available for various tests including aluminum, alkalinity, calcium, and chlorine.
Free and Total Chlorine Photometer (HI 96711)
This portable kit measures free and total chlorine, featuring a sample traceability system and CAL CHECK™ validation for performance verification. It logs up to 99 measurements and is compatible with PC for data management.
General Specifications
The photometers are designed for both laboratory and field use, featuring water resistance, a large dual-level LCD, and an advanced optical system. They include a positive-locking system for cuvettes and offer user calibration and verification standards.
Photometers
  • Free/Total Chlorine Photometer (HI 96724): Measures chlorine content in water samples (0.00 to 5.00 mg/L).
  • Copper, Low Range Photometer (HI 96747): Measures dissolved copper in water (0.000 to 1.500 mg/L).
  • Anionic Detergents Photometer (HI 96769): Measures anionic detergents in water (0.00 to 3.50 mg/L).
  • Nitrite, Low Range Photometer (HI 96707): Measures nitrite content in water (0.000 to 0.600 mg/L).
  • Silica Photometer (HI 96770): Measures silica content in water (0 to 200 mg/L).
  • Fluoride, Low Range Photometer (HI 96729): Measures fluoride content in water (0.00 to 2.00 mg/L).
Magnetic Stirrers
  • HI 301N and HI 311N: Heavy-duty stirrers with dual range precision, capable of stirring up to 5 liters.
  • HI 180 Series: Compact stirrers available in various colors, suitable for small volume stirring.
Temperature Monitor
  • HI 147 Checkfridge™: Accurate thermometer for monitoring refrigerators and incubators, featuring CAL CHECK™ verification and magnetic backing.
pH and ORP Electrodes
  • Various electrodes designed for specific applications, featuring different materials and specifications for pH and ORP measurements.
Solutions
  • Includes pH technical solutions, ORP standard solutions, electrode refill solutions, and cleaning solutions for maintaining electrode performance.
Specifications
The document provides specifications for various ion selective electrodes (ISE) and reference electrodes. The temperature range for these electrodes is 0 to 80°C, with a body outer diameter of 12 mm and an insertion length of 120 mm. The body materials include Epoxy, PEI, PVC, and combinations thereof. The electrodes come with a 1 m coaxial cable and a BNC connector. Fill solutions such as HI 7072, HI 7075, and HI 7082 are recommended but not included.
Electrode Types
1. Liquid Membrane Electrodes: Available as single half-cells or combination electrodes, these have a polymer matrix with organic ion-exchangers for ion selectivity. They are suitable for nitrate measurements.
2. Solid State Electrodes: These include a solid sensing surface made of compressed silver halides or crystalline material, suitable for chloride, fluoride, and silver ions.
3. Combination Electrodes: These integrate a sensor and reference electrode in one body, offering the same selectivity as ISE half-cells with a double junction reference.
Standards and Solutions
HANNA provides various standards for fluoride and nitrate measurements, including premixed solutions with TISAB II. Silver-free reference fill solutions are recommended for optimal performance, available in different compositions such as KNO3 and KCl.
Accessories
HANNA offers replacement parts and accessories like liquid membrane sensor handles, halide polishing strips, and modules for combination electrodes. Ionic Strength Adjusters (ISA) are available to maintain constant ionic strength and adjust pH.
Reference Electrodes
The HI 5315 reference electrode is a silver/silver chloride half-cell with a replaceable outer fill solution, designed for use with ISE sensors. It features a fast-responding liquid junction and excellent reproducibility.
Contact Information
The document lists contact details for HANNA instruments across various regions including Africa, Americas, Asia, Europe, and Oceania, providing phone numbers, fax numbers, and email addresses for customer support.
See more

Catalog excerpts

HANNA instruments Drinking Water Catalog-1

Products for the Analysis of Drinking Water

 Open the catalog to page 1
HANNA instruments Drinking Water Catalog-2

HANNA is Dedicated to the testing and monitoring of drinking water, our most precious resource. Contents Turbidity and Chlorine . .4-9, 24-25, 27 Single Parameter Photometers . . .26-28

 Open the catalog to page 2
HANNA instruments Drinking Water Catalog-3

Water sector professionals choose as part of their drinking water monitoring strategy because of our performance, quality and value.

 Open the catalog to page 3
HANNA instruments Drinking Water Catalog-4

Instruments built to comply with EPA accepted test methods for reporting Turbidity and Chlorine Turbidity and Chlorine Meters • HI 83414 features 4 ranges: Ratio Turbidity; Non-Ratio Turbidity; Free Chlorine; Total Chlorine • HI 88703 features 2 ranges: Ratio Turbidity; Non-Ratio Turbidity • Meets USEPA requirements • CAL CHECK™ for HI 83414 • 2, 3, 4 or 5 point turbidity calibration • Backlit LCD • On-screen tutorial modes • Log and recall up to 200 measurements • Contextual help menus • Auto shut-off • Automatic range selection • Good Laboratory Practice capabilities • Features USB PC connection...

 Open the catalog to page 4
HANNA instruments Drinking Water Catalog-5

Rilio turt-jdKv Built in complete GLP information, <nslrum*fil ifiJ prcst ftttl HISMtt - Turbidity end Free I' Flrfis Turbidity Calibration Error Messages Free (Worme Help Mode Both meters offer interactive contextual help to assist users during measurements, Tutorial Mode Provides additional information to help users during measurements. CAL CHECK™ allows users to check instrument calibration against a NIST traceable standard before making a set of measurements. With the same standard, the instrument could be re- Turbidity in Potable Waters Turbidity is one of the most important parameters used...

 Open the catalog to page 5
HANNA instruments Drinking Water Catalog-6

Instruments built to comply with USEPA accepted methodology for reporting Turbidity and Chlorine Turbidity and Chlorine Meters Turbidity and Free/Total Chlorine Meters The HI 93414 measures two of the most important parameters of drinking water: turbidity and free and total chlorine while the HI 98703 measures turbidity only. Both meters are EPA compliant and feature 3 turbidity measurement ranges: 0.00 to 9.99 NTU, 10.0 to 99.9 NTU, and 100 to 1000 NTU. Reliable performance of the HI 93414 is validated using HANNA's exclusive CAL CHECK™ system and ready-made, NIST traceable chlorine standards....

 Open the catalog to page 6
HANNA instruments Drinking Water Catalog-7

• Tungsten light source—EPA compliant turbidity measurement • High accuracy at low ranges • Exclusive chlorine CAL CHECK™ calibration validation (HI 93414 only) • Log up to 200 readings • User replaceable light source • 2, 3 or 4 point turbidity calibration • USB and RS232 PC connectivity • Backlit LCD • GLP capability • User friendly display with guidance codes • Auto shut-off • Battery percentage on display • Continuous current time on display A Revolution in Organized Data Management Fast Tracker™ Tag Identification System (T.I.S.) HANNA’s exclusive Fast Tracker™ — Tag Identification System...

 Open the catalog to page 7
HANNA instruments Drinking Water Catalog-8

Turbidity Testing Water clarity is paramount when producing water for human consumption. Turbidity, an optical property, is a measure of the cloudiness of water. Turbidity causes light to be scattered and absorbed rather than transmitted. The measurement of turbidity is used to indicate water quality and filtration effectiveness. Increases in suspended and colloidal matter increase turbidity. These levels are often associated with higher levels of disease-causing microorganisms such as viruses, parasites and some bacteria that can cause symptoms such as nausea, cramps, diarrhea, and associated...

 Open the catalog to page 8
HANNA instruments Drinking Water Catalog-9

The HI 88713 is a high accuracy meter designed for low turbidity. This instrument exceeds the requirements of ISO 7027 standard The HI 98713 ISO Portable Turbidity meter meets and exceeds the requirements of the ISO 7027 for water quality. • Normal, average and continuous measuring modes Range NTU Ratio Mode Range Selection Resolution NTU Ratio Mode 0.01 FTU from 0.00 to 9.99 FTU 0.1 FTU from 10.0 to 99.9 FTU 1 FTU from 100 to 1000 FTU Accuracy NTU Ratio Mode NTU Non-Ratio Mode Repeatability Stray Light Light Detector / Light Source Method Turbidity Standards ±2% of reading plus stray light /...

 Open the catalog to page 9
HANNA instruments Drinking Water Catalog-10

Simultaneous Dual Graph Display Research Grade pH, ISE and ORP Meter Tailored to your Application HANNA’s new research grade laboratory pH/mV/ISE benchtop meter features a 240 x 320 dot-matrix color display with on-screen help, dual-channels, simultaneous graphing, language selection and custom configuration. • Exclusive Calibration Check™ for pH • 240 x 320 color display • Simultaneous dual graph display and real-time logging • USB and RS232 for computer compatibility • Multi-language interface • Logging, graphing and GLP capabilities • Manual or automatic temperature compensation • Relative...

 Open the catalog to page 10
HANNA instruments Drinking Water Catalog-11

Extend your Parameter Measurement with Ion Selective Electrodes Chloride (Titration) * Fluoride (Direct) * Nitrate (Direct) * Chloride is a common non-toxic material present in small amounts in drinking water and produces a detectable salty taste at the aesthetic objective level of 250 mg/L (limit referred to the EPA MCL (maximum contaminant level). Measured levels are normally under 20 mg/L (ppm). The EPA’s National secondary drinking water standard for chloride is set at 250 mg/L (ppm). Fluoride is a water additive which promotes strong teeth. Many public water systems add low levels of fluoride...

 Open the catalog to page 11
HANNA instruments Drinking Water Catalog-12

Backlit Multi-level Display Calibration Check™ pH Meter • Exclusive Calibration Check™ • Electrode condition monitoring • Backlit, multi-level LCD with on-screen guide • Up to 7 standard and 2 custom calibration buffers • User-selectable calibration timeout reminder • Measures in °C or °F • Waterproof • Rechargeable batteries • BEPS (Battery Error Prevention System) Accurate and Versatile The HI 9126 is ideal for on-site spot checks. It’s sleek, portable casing and large LCD with backlight works with the operator to achieve fast and accurate results in a variety of testing locations, such as...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.