1. Catalogs
  2. Hanna Instruments
  3. Aquaculture Catalog

Aquaculture Catalog

Aquaculture Catalog
1 / 50 PagesView full catalog

Aquaculture Catalog

Product catalog summary
Overview: The 2006-2007 HANNA Aquaculture and Aquarium Catalog offers a wide range of products for measuring water quality parameters crucial for aquaculture and aquarium applications. It serves both large-scale farmers and hobbyists with products like microprocessor controllers, ion-specific photometers, and pocket testers.
Product Categories:
  • Testers: Includes pH, EC/TDS, and combination testers. Pocket testers such as the HANNA Checker® 1 and pHep® are noted for their affordability and accuracy.
  • Portable Meters: Covers pH/ORP, EC/TDS, light, temperature, dissolved oxygen, and relative humidity meters, emphasizing reliability and waterproof design.
  • Chemical Test Kits and Photometers: Offers bench, aquaculture-specific, and portable photometers for precise chemical analysis.
  • Monitors and Controllers: Features pH, EC/TDS, and combination monitors, along with mini controllers and dosing pumps for advanced monitoring and control.
Technical Insights:
  • pH Measurement: Discusses the advantages of pocket testers over handheld meters, emphasizing accuracy for pH-sensitive species and the selection of pH electrodes based on application.
  • EC/TDS Measurement: Highlights waterproof testers with replaceable electrodes and automatic temperature compensation for accurate salinity measurements.
Application Example: A case study on using pocket testers in a saltwater hatchery illustrates challenges like salt crystallization and the benefits of double junction electrodes.
Specifications and Accessories: Provides detailed specifications for various models, including range, resolution, accuracy, and environmental conditions, along with accessories like calibration solutions and replacement electrodes.
Key Considerations:
  • pH stability is crucial for aquatic health, affecting ammonia toxicity and organism stress.
  • ORP indicates water's ability to oxidize contaminants, with optimal levels between 250-400 mV.
  • Portable meters offer enhanced durability and accuracy compared to pocket testers.
Conductivity and Total Dissolved Solids (TDS): Conductivity measures water's ability to conduct electricity, influenced by inorganic dissolved solids. Applications include monitoring TDS for sensitive species and assessing R/O unit efficiency.
Portable Meters and Accessories: HANNA instruments offer various meters and accessories for measuring pH, ORP, EC, and TDS, with features like automatic calibration, temperature compensation, and data logging.
Conclusion: HANNA instruments provide a comprehensive range of portable meters and accessories for precise and reliable measurements in various environmental conditions, supporting applications in aquaculture and water quality testing.
HI 9828 Multiparameter Probe: Designed for reliable field measurements, it supports quick calibration for pH and conductivity and measures seven parameters, including pH, ORP, EC, and temperature.
Key Features:
  • 4-Ring Conductivity System: Ensures stable readings unaffected by surface coating.
  • Galvanic D.O. Sensor: Includes a thermistor for fast temperature-corrected readings.
  • Automatic Sensor Recognition: Detects pH or pH/ORP sensors, which are gel-filled for contamination resistance.
Specifications: Includes ranges and accuracies for pH, ORP, dissolved oxygen, conductivity, and temperature.
Logging and Connectivity: Stores up to 60,000 samples, with USB interface for data transfer.
Power and Durability: Powered by rechargeable batteries with inductive recharging, offering up to 200 hours of operation. The device is IP67 rated for waterproof protection.
Ordering Information: The HI 9828 package includes the probe, calibration solutions, maintenance kit, rechargeable batteries, power adapter, USB interface cable, and software, all housed in a rugged carrying case.
Dissolved Oxygen Meters: Detailed information on various models designed for aquaculture and water quality monitoring, highlighting features like galvanic probes, automatic temperature and salinity compensation, and logging capabilities.
Photometers for Aquaculture: Essential for monitoring water quality, these devices are lightweight, computer compatible, and capable of measuring multiple parameters. Models like HI 83200 and HI 83203 can measure up to 36 parameters.
Recommendations and Best Practices: Emphasizes the importance of maintaining water quality for fish health and recommends frequent testing with ion-specific photometers.
Conclusion: The document provides comprehensive information on the specifications, capabilities, and applications of various photometers designed for aquaculture, highlighting the importance of accurate water quality testing.
Temperature Indicator HI 148: Features continuous ambient temperature monitoring with a visible LED alarm and includes an LCD display, probe, battery, and instructions.
Mini Controllers BL Series: Designed for water analysis and control, suitable for both small research systems and large commercial tanks, with features like panel mounting and selectable overdose protection.
HI 504 pH/ORP Controller: Offers features like RS 485 interface for networking, Sensor Check™ for probe diagnostics, and an auto-cleaning cycle.
HI 700 / HI 710 Conductivity and TDS Controllers: Provide accurate and reliable measurements with programmable settings and multiple output options.
General Features: All models are designed for easy installation and operation, with features like automatic calibration and user-friendly interfaces.
Power Supply Options: Lists two power supply options: 115 VAC and 230 VAC.
Accessories: Includes various calibration solutions and the HI 504901 GSM supervisor.
Blackstone Series Chemical Metering Pumps: Highlighted for their reliability and high-quality materials, suitable for aquaculture applications.
Warranty and Returns: Outlines warranty periods and the process for returns, exchanges, and service.
Participating Dealers: Provides a list of authorized distributors and dealers with contact information.
See more

Catalog excerpts

Aquaculture Catalog-1

See Back Page for details >

 Open the catalog to page 1
Aquaculture Catalog-2

Mini Controllers36 NEMA Enclosures37 > Level37 > HANNA Highland Industrial Park 584 Park East Drive, Woonsocket, RI 02895 Panel Mount Controllers38-40 pH/ORP with Sensor CheckΙ38 pH39 > phone: (800) 426-6287fax: (401) 765-7575e-mail: [email protected]: www.hannainst.com mV39 Conductivity and TDS40 >

 Open the catalog to page 2
Aquaculture Catalog-3

Q.Whats the difference between single and double junction electrodes? What does that mean to me?A. > The electrode junction is the bridge between the sample and the electrolyte surrounding the internal pH sensing elements. A single junction has only one barrier between the sample and the electrolyte,and a double junction has two. A double junction has the advantage of slowing possible contamination of the electrolyte due tochemically aggressive samples. The application will be the deciding factor of the kind of junction you need. If you are testing fresh water, or you wonҒt be testing very often,...

 Open the catalog to page 3
Aquaculture Catalog-4

Range 0.00 to 14.00 pH Resolution 0.01 pH Accuracy > (@20ΰC/68F) б0.2 pH > pH Calibration Manual 2 points Battery Type (2) 1.5V AA Battery Life Approx. 3000 hours of continuous use Environment 0 to 50԰C (32 to 122F); max. 95% RH Dimensions > (meter only ) 66 x 50 x 25 mm (2.6 x 2 x 1Д) Weight 70 g (2.5 oz) > HI 98103 (Checker > 1) is supplied with HI 1270 combinationpH electrode, batteries and instructions. > HI 1270 pH electrode, screw connector HI 1208 pH electrode, BNC connector HI 7004M pH 4.01 buffer sol., 230 mL > HI 7007M pH 7.01 buffer sol., 230 mL HI 7010M pH 10.01 buffer sol., 230 mL...

 Open the catalog to page 4
Aquaculture Catalog-5

Range 0 to 1999 ppm (mg/L) Resolution 1 ppm (mg/L) Accuracy > (@20ΰC/68F) б2% F.S. TDS Factor 0.65 Calibration Solution HI 70032P > Calibration Manual 1 point through trimmer Temp. Compensation Automatic from 0 to 50C(32 to 122аF) Battery Type/Life (4)1.5V/Approx. 150 hours ofcontinuous use Environment 0 to 50C (32 to 122аF);max. 95% RH Dimensions 175 x 41 x 23 mm (7.9 x 1.8 x 1) Weight 78 g (2.7 oz) > ή EC: 0.00 to 20.00 mS/cm; TDS: 0.00 to10.00 ppt; Temp.: 0.0 to 60.0C or 32.0 to140.0аF HI 98300 (DiST 1) is supplied with protective cap, batteries andinstructions. Range EC: 0 to 3999 S/cm; TDS:...

 Open the catalog to page 5
Aquaculture Catalog-6

Resolution pH: 0.01; EC: 1 ٵS/cm; TDS: 1 ppm;Temperature: 0.1C or 0.1аF pH: 0.01; EC: 0.01 mS/cm; TDS: 0.01 ppt;Temperature: 0.1C or 0.1аF > Accuracy > (@20C/68аF) pH: 0.05; EC/TDS: ѱ2% F.S.; Temperature: 0.5ѰC or 1ѰF pH Calibration 1 or 2 points with 2 sets of memorized buffers EC/TDS Calibration Automatic 1 point EC/TDS Conv. Factor Adjustable from 0.45 to 1.00 Temp Comp. pH: automatic; EC/TDS: automatic, BETA ( β ) is adjustable from 0.0 to 2.4%/C Battery Type (4) 1.5V with BEPS (Battery Error Prevention System) > Battery Life Approx. 100 hrs of continuous use; auto shut-off after 8 minutes...

 Open the catalog to page 6
Aquaculture Catalog-7

Range pH: -2.00 to 16.00; ORP: 1000 mV; Temp.: -5.0 to 60.0ѰC or 23.0 Resolution pH: 0.01; ORP: 1 mV; Temperature: 0.1C or 0.1аF Accuracy (@20C/68аF) pH: 0.05; ORP: ѱ2 mV; Temperature: 0.5ѰC or 1ѰF pH: 1 or 2 points with 2 sets of memorized buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18); ORP: Factory calibrated > Calibration Temp. Compensation Automatic for pH Battery Type (4) 1.5V with BEPS (Battery Error Prevention System) Battery Life Approx. 250 hours of continuous use; auto shut-off after 8 minutes of non-use Environment -5 to 50C (23 to 122аF); 100% RH Dimensions 163 x 40 x 26 mm (6.4...

 Open the catalog to page 7
Aquaculture Catalog-8

ՕCalibration Check: pH electrode condition, clean electrode/contaminated buffer warning, outside calibration range warningٕ0.001 pH resolution Stainless steel pH electrode with built-in temperature sensor ՕUp to 3 calibration points with standard or custom buffersRelative mV scale The hand held meter is a sophisticatedinstrument and incorporates many useful features not found in a pocket tester. Hand- held instruments are also more durable and have a longer useful life than pocket testers. If your major concern is cost and good basic performance, then the pocket tester may be the right fit for...

 Open the catalog to page 8
Aquaculture Catalog-9

Range pH: -2.0 to 16.0; -2.00 to 16.00; Temp: -20.0 to 120.0 ٰC (-4.0 to 248.0F) pH: -2.0 to 16.0; -2.00 to 16.00; mV: б2000; Temp: -20.0 to 120.0 C (-4.0 to 248.0аF) > Accuracy pH: 0.01; Temp: ѱ0.4C (б0.8F) (excluding probe error) pH: б0.01; mV: 0.2 mV; Temp: ѱ0.4C (б0.8F)(excluding probe error) pHCalibration Up to 2 point calibration, 7 standard buffers available(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) Up to 3 point calibration, 7 standard buffers available(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) > Temp. Compensation Manual or automatic from -20.0 to 120.0аC (-4.0 to 248.0F) Probes...

 Open the catalog to page 9
Aquaculture Catalog-10

Range pH: -2.0 to 16.0; -2.00 to 16.00; mV: 699.9 mV; ѱ2000; Temp.: -20.0 to 120.0 C (-4.0 to 248.0аF) Resolution pH 0.1; 0.01; mV: 0.1; 1; Temp.: 0.1 (0.1аF) Accuracy (@20C/68аF) pH: 0.01; ѱ0.01; mV: 0.2 mV (ѱ699.9 mV); 1 mV (ѱ2000 mV); Temp.: 0.4ѰC (0.8ѰF)excluding probe error pHCalibration Up to 5 calibration points; 7 standard buffers available (pH buffers 1.68, 4.01, 6.86, 7.01, 9.18,10.01, 12.45) and 5 custom buffers Slope/Offset Calibration 1 pH/From 80 to 110% Relative mV Offset Range ѱ2000 mV > Temp. Compensation Automatic or manual from -20.0 to 120.0C (-4.0 to 248.0аF) Electrodes HI1230B...

 Open the catalog to page 10
Aquaculture Catalog-11

Range pH: -2.00 to 16.00; mV: ձ699.9 to 1999; Temp.: -20.0 to 120.0ѰC/-4.0 to 2482.0F Resolution pH: 0.01; mV: 0.1, 1; Temperature: 0.1аC/0.1F Accuracy > (@20аC/68F) pH: б0.01; mV 0.2, ѱ1; Temperature: 0.4ѰC/0.8ѰF Calibration Check Check of the electrode status during calibration pH Calibration Automatic, 1 or 2 point with 7 memorized buffer values (pH 1.68, 4.01, 6.86, 7.01,9.18, 10.01, 12.45); + 2 custom buffers Temp Comp Automatic or manual, -20 to 120ٰC (-4F to 248аF) pHElectrode HI 1230B, double junction, PEI body, gel filled, BNC conn. and 1 m cable (included) Temperature Probe HI 7669...

 Open the catalog to page 11
Aquaculture Catalog-12

pH: 0.00 to 14.00;Temperature: 0.0 to 100.0C/32.0to 212.0аF pH: 0.00 to 14.00; mV: 399.9 to ѱ1999;Temperature: 0.0 to 100.0C/32.0to 212.0аF Range Resolution pH: 0.01; Temperature: 0.1C/0.1аF pH: 0.01; mV: 0.1, 1;Temperature: 0.1C/0.1аF Accuracy > (@20C/68аF) pH: 0.01; Temperature:ѱ0.4C/б0.8F pH: б0.01; mV: 0.2, ѱ1;Temperature: 0.4ѰC/0.8ѰF Conductivity(mS/cm) RefractiveIndex SpecificGravity PSU pH Calibration Automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18,10.01); offset calibration: 1 pH; slope calibration: 70 to 108% (25ѰC) (20C) (25аC) Temp. Compensation Automatic...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.