zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking
8Pages

{{requestButtons}}

Catalog excerpts

zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 1

HANGZHOU ZETIAN TECHNOLOGY CO.,LTD.

Open the catalog to page 1
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 2

Focusing on Environmental & Industrial Analysis Hangzhou Zetian Technology Co., Ltd. is located in high-tech development zone of Binjiang District, Hangzhou, China. There are more than 20000 square meters for official business and manufacture. Zetian is a professional manufacturer specialized in R & D, producing and selling online monitoring instruments for environmental monitoring, industrial process control and industrial safety. Zetian strictly follows the standard of ISO9001 quality system to develop and produce, and also increase both its production quality and service quality by...

Open the catalog to page 2
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 3

EM-5 Continuous Emission Monitoring System System introduction EM - 5 continuous emissions monitoring system (CEMS) of Hangzhou Zetian Technology Co.,Ltd. can monitor gases, including S02, NOx, 02, dust, humidity, temperature, pressure, flow parameters, etc. It can be widely used in all kinds of component continuous monitoring situations such as boilers, industrial furnaces, incinerator emissions, etc. In addition, EM - 5 also can monitor gases for a particular occasion such as HC1, HF, CO, C02, NH3, H2S, Cl2, VOC, etc.. Zetian technology is the only high and new technology company with a...

Open the catalog to page 3
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 4

EM-5 Continuous Emission Monitoring System (CEMS) consists of particulate matter monitoring subsystem, gaseous pollutants monitoring subsystem , flue gas parameters monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor gases such as S02, NOx, 02, dust, temperature, pressure, flow rate, humidity, etc. It can also be extended for a specific occasion to monitor HC1, HF, CO, C02, NH3, H2S, Cl2, VOC and other parameters. The measured gas passes through sampling probe for dedusting, heating tube for sampling, then goes into the gas analysis module...

Open the catalog to page 4
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 5

EM-5Hg Continuous Emission Monitoring System Working princilie The flue gas in the flue is under the action of the sampling pump. Through sampling probe, sampling probe, heat tracing pipe, filter, sampling valve, sampling pump and filter, enter the analyzer. The analyzer uses UV DOAS technology to analyze the gas and obtain the concentration of various components, and the flue gas is discharged outside. By controlling sampling ball valve and back-blowing solenoid valve, the system can regularly back-blow to the probe. It can realize regular automatic zero adjustment function. The system has...

Open the catalog to page 5
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 6

Introduction of the subsystem measuring instrument -Flue gas analyzer -Dust monitor -Integration monitor of the temperature, pressure flow -Laser gas analyzer ★ Warm-up Time: None ★ Relay Output: 14,output can be flexible configuration,DC30V 2A ★ Digital Input: 6,can be flexible configuration ★ Analog Output: 5x4-20mA,flexible configuratiorynax load 800Q ★ Analog Input; 3x4-20mA, flexible configuration,loadlOOQ ★ Digital Comm.: lxRS485, 1XRS232, lx GPRS (Optional) ★ Enclosure Rating: IP42 ★ Working Temp.; -20tl - +50*0 ★ Working Humidity: 0~95%RH * Measuring Technique: DOAS (S02% NOx),...

Open the catalog to page 6
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 7

Introduction of the subsystem measuring instrument ♦ Product description PT-500 is designed for low velocity (2m/s~5m/s) applications. The instrument uses precision micro-differential pressure/static press, sensor and unique pitot tube structural design, combined with auto. cal. and cleaning. It can be widely used for real-time and continuous measurements of flue gas temp., press., and velocity as well as flow quantity. ♦Technical index ★ Velocity: 0**15.5m/s, 0 ~ 40m/s(customizable) ★ Temperature: 0 ~ 300*0, 0 ~ 800*0(customizable) ★ Pressure: -lOkPa*» +10kPa(customizable) ★ Measuring...

Open the catalog to page 7
zetian/continuous emission monitoring system/condensation/flue gas analyzer/EM-5-CD/DeSOx/DeNOx/power plants/Waste incineration/cement/steel marking - 8

Look forward to working with you ■ The sample is the general information publication, we reserve the right to change product technology and instructions, are subject to change without prior notice. ■ Please refer to our actual product s specific parameters. Please consult the sales before buying or phone service. Hangzhou Zetian Technology Co.,Ltd. Phone: 86-13588711905 86-571-28322780 Fax: 86-571-87851772 E-mail : export@zetian-tech.com Post Code: 310053 Add: 22 Zhiren Street, Binjiang District, Hangzhou website: www.zetian-tech.com