1. Catalogs
  2. Hangzhou Chunlai Technology Co., Ltd.
  3. zetian/Temperature,pressure&Flowrate Integrated Monitor/industrial process/iron making, steel making, coking, refining, petrochemical, flue gas, cement, thermal power

zetian/Temperature,pressure&Flowrate Integrated Monitor/industrial process/iron making, steel making, coking, refining, petrochemical, flue gas, cement, thermal power

zetian/Temperature,pressure&Flowrate Integrated Monitor/industrial process/iron making, steel making, coking, refining, petrochemical, flue gas, cement, thermal power

Product catalog summary
Overview:
The PT-500H is an integrated monitor designed for continuous monitoring of high dust levels, high temperatures, high humidity, and low flow rates in emission flue gas. It features a high-precision micro-differential pressure sensor and static pressure sensor, along with a purge unit. It is compatible with Continuous Emission Monitoring Systems (CEMS) for real-time monitoring of temperature, pressure, and velocity.

Installation Instructions:
The PT-500H can be installed vertically or horizontally. During installation, ensure the pitot direction aligns with the flue gas flow: the total pressure port should face the incoming gas, and the static pressure port should face the outgoing gas.

Specifications:
  • Flow rate range: 0-40m/s; 0-15m/s (optional)
  • Accuracy: ±5% Full Scale
  • Principle: Pitot
  • Output signal: 3x 4-20mA, 1x RS232/485
  • Pressure limit: 4.0 MPa
  • Pitot material: 316 SS, 316L SS
  • Pitot insert length: 500-1700 mm (optional)
  • Pressure transmitter range: -5kPa to 5kPa, -200kPa to +200Pa (customizable)
  • Temperature transmitter range: 0-300°C (customizable)
  • Purge pressure: 0.3MPa to 0.8MPa
  • Flue gas temperature range: -40°C to 300°C (customizable)
  • Operating temperature: -40°C to 70°C
  • Storage temperature: 0-50°C
  • Storage humidity: 0-85% RH

Features:
  • Capable of measuring low flow rates down to 2m/s
  • Equipped with an LCD screen for easy data reading and debugging
  • Settable parameters include timing purge, velocity field, and pitot coefficient
  • Overpressure protection to prevent sensor damage and reduce operational costs
  • Auto zeroing calibration
  • Anti-blocking and anti-corrosion features for the pitot
  • Enhanced protection for signal output

Contact Information:
Hangzhou Zetian Technology CO., Ltd
Address: 7th Floor, 2nd Building Taiheng Mansion, NO. 22 Zhiren Street, Binjiang District, Hangzhou, Zhejiang, China (310053)
Tel: 0571-28322780
Email: [email protected]
Web: www.zetian-tech.cn
See more

Catalog excerpts

zetian/Temperature,pressure&Flowrate Integrated Monitor/industrial process/iron making, steel making, coking, refining, petrochemical, flue gas, cement, thermal power-1

PT-500H Temperature, pressure & Flowrate Integrated Monitor Overview PT-500H Temperature, pressure & velocity integrated monitor has high precise micro-differential pressure sensor and static pressure sensor. Meanwhile, it is equipped with purge unit. PT-500H is specially developed for continuously monitoring high dust level, high temperature, high humidity and low flow rate of emission flue gas. It can be applied with CEMS to carry our real time monitor of temperature, pressure and velocity. Compared with conventional integrated monitor: PT-500H can measure flow rate low to 2m/s and has auto timing or manual calibration for dynamic pressure and flow rate; with LCD screen to display all measurement data and signal; easy for reading and debugging. Installation instruction When taking differential pressure, differential pressure transmitter needs to measure total pressure and static pressure. So special attention should be paid to pitot direction during installation. Make sure the direction of two pressure taking ports is the same as flow direction of flue gas: total pressure taking port is directed to coming direction of flue gas and static pressure taking port is directed to leaving direction of flue gas. There are two installation methods, vertical installation and Horizontal Installation, as following firgue: Flue gas direction Flue gas direction Specification Range: 0~40m/s;0~15m/s (Optional) Accuracy: ± 5%F.S. Vertical installation Principle: pitot Horizontal installation Pressure limit of differential pressure transmitter: 4.0Mpa ` Pitot insert length: 500~1700Mm (Optional) 2m/s low flowrate measurement by pressure sensor of ultra-low range Operation unit with LCD screen: perfect HMI provided Settable parameters: timing purge, velocity field, pitot Range of temperature transmitter: 0~300℃ (customizable) Purge pressure: 0.3MPa~0.8MPa Protection for over pressure to avoid damage to pressure sensor and lower operation cost Temperature range of flue gas: -40℃~300℃ (customizable) Work temperature: -40℃~70℃ Auto zeroing calibration Anti-blocking and anti corrosion for pitot Strengthen protection for signal output Hangzhou Zetian Technology CO., Ltd Add: 7th Floor, 2nd Building Taiheng Mansion, NO. 22 Zhiren Street, Binjiang District Hangzhou, Zhejiang, China (310053) Tel: 0571-28322780 Email: export@

 Open the catalog to page 1

All Hangzhou Chunlai Technology Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.