Product catalog summary
Overview
The LGT-180 is a 19" panel-mounted tunable laser gas analyzer designed for industrial online analysis and environmental monitoring. It utilizes TDLAS technology and multiple reflection long optical path technology to analyze various gases such as O2, CO, NH3, H2S, CO2, CH4, and H2O. The system is customizable to meet specific working conditions and can measure gas concentrations from constant levels to trace amounts.
System Composition and Features
  • Compact structure for easy integration.
  • Strong anti-interference capability with high precision and minimal drift.
  • Low detection limit and high sensitivity, adaptable to corrosive environments.
  • Components exposed to sample gas are made of corrosion-resistant materials.
  • Sampling measurement method with no moving parts for high reliability.
  • Multi-reflection technology extends optical path up to 25m, enhancing detection limits to ppm or even ppb levels.
  • Wavelength-modulation-spectroscopy improves anti-interference and reliability.
  • 19" standard 3U panel chassis with modular design for easy integration.
Technical Specifications
  • Linearity Error: ≤±1% F.S.
  • Repeatability: ≤1%
  • Span Drift: ≤±1% F.S./half year
  • Zero Drift: ≤±1% F.S./half year
  • Maintenance Cycle: ≤2 times/year
  • Calibration Cycle: ≤2 times/year or automatic calibration
  • Enclosure Rating: IP54
  • Response Time (T90): ≤30s
Interface and Operating Conditions
  • Analog Output: 2× 4-20mA output (isolation, max load 750Ω)
  • Analog Input: 2× 4-20mA input (temperature and pressure compensation)
  • Digital Output: RS485/RS232/GPRS
  • Relay Output: 3 (24V, 1A)
  • Power Supply: 100VAC to 240VAC
  • Purge Gas: 0.3MPa to 0.8MPa industrial nitrogen or purified air
  • Ambient Temperature: -20℃ to +60℃
Installation and Maintenance
  • Sampling installation method.
  • Panel-mounted in cabinets with options for black or white chassis.
  • 5.5" OLED display with mechanical button operation.
  • Analog and binary signal output from the back-panel.
  • Contains power conversion module for direct power supply through the rear interface.
  • Modular design facilitates easy installation and maintenance.
See more

Catalog excerpts

zetian/laser gas analyzer/rack mounted/TDLAS/industrial process/LGT-180/iron making, steel making, coking, refining, petrochemical, flue gas, cement, thermal power-1

LGT-180 Laser Gas Analyzer LGT-180 is a 19" panel mounted type tunable laser gas analyzer for industrial online analysis and environmental on-line monitoring. The analyzers combine TDLAS technology and multiple reflection long optical path technology that can analysis a variety of gas including O 2, CO, NH 3, H 2S, CO 2, CH 4, H 2O. Reflected light can be customized according to the working condition demand, the measured gas concentration ranges from constants to the trace. System Composition Transmitter, receiver and gas cell are integrated into a 19" 3U chassis. Analyzer can be panel mounted in a 19" cabinet. Sample gas is filtered and dewatered through probe. Then in the gas cell, it is exposed to laser emitted from the transmitter. The receiver calculates the gas concentration from the spectrum received. structure, easy integration 19" standard 3U panel chassis, modular design, easy integration with other instruments. Strong anti-interference capability, high precision, small drift Adopting wavelength-modulation-spectroscopy allows better anti-interference capability of background gas and higher reliability. detection limit, high sensitivity Multi-reflection technology achieves optical path up to 25m, improving detection limit greatly. The sensitivity can reach ppm level or even ppb level for some components. For applications in corrosive environment, all parts of LGT-180 exposed to sample gas are made of corrosion-resistant material. System adopts the sampling measurement method. It can be directly installed in the process pipe to sample, process and analyze, no moving parts, high reliability.

 Open the catalog to page 1
zetian/laser gas analyzer/rack mounted/TDLAS/industrial process/LGT-180/iron making, steel making, coking, refining, petrochemical, flue gas, cement, thermal power-2

H Low Detection Limit Modular design, easy installation and maintenance Multi-reflection gas cell greatly improves detection limit Specification ParameterTechnical Indicators Linearity Error ^ ± 1%F.S. Span Drift ^ ± 1%F.S./half year Zero Drift ^ ± 1%F.S./half year Maintenance Cycle ^ 2times/year(related to the working condition) Calibration Cycle ^ 2times/year(or automatic calibration) Response Time(T90) ^ 30s(related to the working condition) Analog Output 2* 4-20mA output(isolation, max load750^) Analog Input 2* 4-20mA input(temp. and press. compensation) Purge Gas...

 Open the catalog to page 2

All Hangzhou Chunlai Technology Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.