Introduction to TDLAS Technology
Tunable Diode Laser Absorption Spectroscopy (TDLAS) is a precise gas detection technology known for its high sensitivity and resolution. It uses tunable lasers to scan specific gas absorption peaks, making it ideal for industrial and environmental monitoring.
Technical Characteristics
The LGT series laser gas analyzers leverage TDLAS for high selectivity and sensitivity, detecting gases like O2, CO, CO2, NH3, and CH4 with detection limits from ppm to percentage levels. They offer rapid response and versatility, suitable for extreme conditions.
Product Features
The LGT series includes models like:
  • LGT-100: In-situ analyzer with flameproof design for real-time measurement.
  • LGT-106: Bypass analyzer for harsh conditions with automatic calibration.
  • LGT-150: Multi-channel analyzer supporting up to 8 probes.
All models feature modular design, high reliability, and strong anti-interference capabilities.
Installation and Maintenance
These analyzers support in-situ and panel-mounted installations, with features like easy optical path adjustment and remote operation. Maintenance is minimal, requiring calibration only twice a year.
Technical Specifications
Key specifications include:
  • Linearity Error: ≤±1% F.S.
  • Response Time: ≤1s for LGT-100 and LGT-150, ≤30s for LGT-106
  • Enclosure Ratings: IP66 for probes, IP54 for central units
  • Operating Conditions: -20℃ to +60℃, with power supply of 24VDC or 100-240VAC
Overview
The document details the LGT-150, LGT-180, and LGT-200 analyzers, part of the Solutions Laser Process Gas Analysis System, using TDLAS for gas monitoring.
System Composition and Features
These analyzers are compact, precise, and feature strong anti-interference capabilities. The LGT-180 and LGT-200 use multi-reflection technology for enhanced detection limits.
Technical Specifications
- Linearity Error: ≤±1% F.S.
- Repeatability: ≤1%
- Span Drift: ≤±1% F.S./half year
- Zero Drift: ≤±1% F.S./half year
- Maintenance Cycle: ≤2 times/year
- Calibration Cycle: ≤2 times/year or automatic
- Enclosure Rating: IP54 for LGT-180, IP65 for LGT-200
- Response Time (T90): ≤30 seconds
Operating Conditions
- Power Supply: 100VAC to 240VAC
- Ambient Temperature: -20℃ to +60℃ for LGT-180, -20℃ to +55℃ for LGT-200
- Installation: Sampling installation with panel mounting options
Applications
The LGT series is suitable for industries like metallurgy, petrochemicals, and cement production, analyzing gases such as O2, CO, CO2, CH4, NH3, H2S, H2O, HCl, and HF.
Product Comparison
The document compares the LGT series with competitors, highlighting modular design, explosion-proof capabilities, and ease of installation.
Contact Information
For more information, contact Hangzhou Zetian Technology Co., Ltd. via phone, fax, email, or visit their website.
See more

Catalog excerpts

zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-1

£ET/AN Process & Environmental Hangzhou Zetian Technology Co.,Ltd.

 Open the catalog to page 1
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-2

TDLAS Tunable Diode Laser Absorption Spectroscopy TDLAS Technology TDLAS( Tunable Diode Laser Absorption Spectroscopy) mainly uses the character that tunable laser's narrow band and wavelength change with the current. So by precisely modulating the current of tunable laser, it can scan a certain absorption peak of detected gas (no absorption of background gas). And after obtaining the second harmonics absorbed by detected gas, it finally works out the concentration of detected gas by using this second harmonics and line-width.At present, the TDLAS technology has developed into a kind of high...

 Open the catalog to page 2
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-3

LGT Series Laser Gas Analyzer Product Introduction Based on unique tunable diode laser absorption spectrum technology, Hangzhou Zetian Technology Co., Ltd. has designed and developed LGT series laser gas analyzer for industrial online analysis and environmental online monitoring with different types including in-situ probe type, bypass type, multi-channel type, panel mounted type and flameproof type, etc. Laser gas analyzers are used in a wide variety of applications to measure O 2, CO, NH 3, CO 2, CH 4, H 2O, HCl and HF, etc. Measuring concentration ranges from constant to trace. Product Characteristics...

 Open the catalog to page 3
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-4

LGT-100 Laser Gas Analyzer LGT-100 is a flameproof tunable laser gas analyzer for industrial online analysis and environmental on-line monitoring, which can in-situ analyze O 2, CO, NH 3, CO 2, CH 4, H 2O, HCl, HF and other gases in various complex conditions. It consists of transmitter, receiver and connection box. The transmitter drives the tunable diode to emit laser of certain wavelengths, which passes through the environment to be measured, then reaches the receiver. The receiver performs photoelectricity conversion, signal processing and spectrum data analysis to obtain the measuring result....

 Open the catalog to page 4
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-5

LGT-100 Laser Gas Analyzer Easy Optical Path Adjusting Self Diagnose Function XY direction non-coupling adjusting, easy adjusting Comprehensive self diagnose function, records and saves alarm information, easy to check Adjusting flange Instrument flange Adjusting tool Specification Parameter Technical Indicators Optical Channel Length Linearity Error Span Drift Zero Drift Maintenance Cycle Calibration Cycle Enclosure Rating Interface Signal Analog Output Analog Input 2× 4-20mA input(temp. and press. compensation) Digital Output Relay Output Operating Conditions Power Supply 0.3MPa~0.8MPa industrial...

 Open the catalog to page 5
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-6

LGT-106 Laser Gas Analyzer LGT-106 is a flameproof bypass type tunable laser gas analyzer for industrial on-line analysis and environmental on-line monitoring, especially suitable for harsh working conditions such as high temperature, high humidity, high dust, high pressure, and for small pipes where in-situ analyzer is not applicable. The transmitter and receiver are installed on a back board. The analyzer contains auto purge function which greatly reduces maintenance cost. System Composition LGT-106 laser gas analyzer consists of transmitter, receiver and gas cell. The transmitter drives the...

 Open the catalog to page 6
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-7

• Suitable for harsh working conditions such as high temperature, high humidity, high dust, high pressure, and for small pipes where are not suitable for in situ measurement occasions. • Integrated structure design, high reliability and stability. • "Single line spectrum" technology, free from interference of background gas. • Innovative Hall button design, high sensitivity, easy operation. • Automatic calibration, automatic backblow. • Adopts imported TO encapsulate semiconductor lasers, optical noises are restrained with antireflective coating end cap. Technical Indicators Linearity Error S...

 Open the catalog to page 7
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-8

LGT-150 Laser Gas Analyzer LGT-150 is a multi-channel type tunable laser gas analyzer based on TDLAS technology. It consists of central control unit and measuring probe. Supporting up to 8 measuring probe, a central control unit controls each measuring probe, processes data received and communicates through network. It supports 19" panel mounted and wall mounted installation. System Composition F i g u r e b e l o w s h o w s L G T- 1 5 0 m u l t i - c h a n n e l distributed measurement. The central control unit realizes human-machine interaction and loading and setting of the parameter in each...

 Open the catalog to page 8
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-9

H Intuitive Real-time concentration profile available, good intuition Specification Parameter LGT-150 Laser Gas Analyzer | Strong Anti-Interference Capability Adopting wavelength-modulation-spectroscopy allows better anti-interference capability of background gas and higher reliability. Technical Indicators Linearity Error =S± 1%F.S. Repeatability s£l% Span Drift =S± 1%F.S./half year Zero Drift sS± 1%F.S./half year Maintenance Cycle 2times/year,clean optical window Probe Type of Protection ExdIICT6 Gb Probe Enclosure Rating IP66 Central Unit Enclosure Rating IP54 Response...

 Open the catalog to page 9
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-10

LGT-180 Laser Gas Analyzer LGT-180 is a 19" panel mounted type tunable laser gas analyzer for industrial online analysis and environmental on-line monitoring. The analyzers combine TDLAS technology and multiple reflection long optical path technology that can analysis a variety of gas including O 2, CO, NH 3, H 2S, CO 2, CH 4, H 2O. Reflected light can be customized according to the working condition demand, the measured gas concentration ranges from constants to the trace. System Composition Transmitter, receiver and gas cell are integrated into a 19" 3U chassis. Analyzer can be panel mounted...

 Open the catalog to page 10
zetian/laser gas analyser/LGT series/metallurgy/petrochemical/environmental/cement/thermal power-11

H Low Detection Limit Modular design, easy installation and maintenance Multi-reflection gas cell greatly improves detection limit Specification ParameterTechnical Indicators Linearity Error ^ ± 1%F.S. Span Drift ^ ± 1%F.S./half year Zero Drift ^ ± 1%F.S./half year Maintenance Cycle ^ 2times/year(related to the working condition) Calibration Cycle ^ 2times/year(or automatic calibration) Response Time(T90) ^ 30s(related to the working condition) 100VAC~240VAC 0.3MPa- 0.8MPa industrial nitrogen, purification instrument air, etc. -20^ - +60^ Interface Signal Analog Output Analog...

 Open the catalog to page 11

All Hangzhou Chunlai Technology Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.