Polilyte PRO VP 120

Polilyte PRO VP 120

Polilyte PRO VP 120

Product catalog summary
Product Overview: The Polilyte PRO VP 120 is a sensor designed for hazardous areas, resistant to HF glass, and equipped with a polymer electrolyte and single pore junction. It is ideal for wastewater and general industrial applications.
Product Specifications:
  • Sensor Family: Polilyte Pro
  • Sensor Output: Traditional mV
  • Length: 120 mm
  • Electrical Connector: VP6
  • Measurement Principle: Combination electrode; pH potential measured against reference
  • Measuring Range: pH 0 to 14
  • Sensitivity: 57 to 59 mV/pH at 25°C
  • Zero Point: 0 ± 20 mV
  • pH Glass Type: Hamilton Type HF Glass
  • pH Glass Resistance: Low
  • Membrane Shape: Spherical
  • Diaphragm: Single Pore
  • Number of Diaphragms: 1
  • Electrolyte: Polisolve
  • Reference System: Hamilton Everef-B
  • Temperature Sensor: Pt1000
  • Diameter: 12 mm
  • Process Connection: PG13,5
  • Wetted Parts: Glass, EPDM
  • O-ring Material: FDA 21 CFR 177.2600; EG 1935/2004; USP <87>; USP <88> Class VI (121°C)
  • Serial Number: Yes
  • Recommended Storage: Hamilton Storage Solution or 3 M KCl
  • Certificate: Yes, with measured values in Buffer pH 4.01 and pH 7.00
Approvals:
  • ATEX Approval: II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
  • IECEx Approval: II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
Limitations:
  • Autoclavable: No
  • CIP: No
  • Steam Sterilizable: No
Operating Conditions:
  • Temperature Range: -10 to 60°C
  • Sample Minimum Conductivity: 2 µS/cm
  • Pressure Range: 0 to 6 bar
Note: Specifications are subject to change without notice.
See more

Catalog excerpts

Polilyte PRO VP 120-1

Polilyte PRO VP 120 Specification Sheet (Part/REF # 238417) Hazardous area approvals, HF resistant glass (pH), polymer electrolyte, and single pore junction these sensors are well suited for waste water and general industrial applications. Product Specifications Sensor Family Sensor Output Electrical Connector Measurement Principle Combination electrode; pH potential measured against reference Measuring Range Zero Point Hamilton Type HF Glass Membrane Shape Single Pore Reference System Hamilton Everef-B Liquid Earth Temperature Sensor Process Connection Wetted Parts Glass EPDM (Ethylene propylene elastomer) O-ring Material Serial Number Recommended Storage Hamilton Storage Solution or 3 M KCl Yes, with measured values in Buffer pH 4.01 and pH 7.00 ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db Steam Sterilizable

 Open the catalog to page 1
Polilyte PRO VP 120-2

Operating Temperature Range Specifications are subject to change without notice https://www.hamiltoncompany.com/sensors/238417