OxyFerm FDA MS 120

OxyFerm FDA MS 120

OxyFerm FDA MS 120

Product catalog summary
Product Overview
The OxyFerm FDA MS 120 is a sensor utilizing Memosens technology, designed for upgrading existing installations with Hamilton's polarographic dissolved oxygen (DO) sensor technology.
Specifications
  • Sensor Family: OxyFerm FDA MS
  • Parameter: DO (Electrochemical)
  • Sensor Output: Memosens
  • Length: 120 mm
  • Electrical Connector: Memosens
  • Measurement Principle: Electrochemical reduction of oxygen
  • Measuring Range: 10 ppb to 40 ppm (DO) or 0.2 to 1000 mbar (pO₂)
  • Drift at Room Temperature: < 1% per week
  • Membrane Cap: Optiflow FDA
  • Electrolyte: Oxylyte
  • Oxygen Consumption: Approximately 20 ng/h in air at 25 °C
  • Temperature Sensor: NTC 22 kOhm
  • Current in Air at 25 °C: 40 - 80 nA
  • Diameter: 12 mm
  • Process Connection: PG13,5
  • Wetted Parts: Stainless Steel 1.4435, EPDM, Silicone - FDA 21 CFR 177.2600, VMQ
  • Surface Quality of Steel: Ra < 0.4 µm (N5)
  • Electrode System: Silver platinum combination
  • Polarization Voltage and Time: -670 ± 50 mV, ≥ 2 hours
  • Serial Number: Yes
  • Response Time t90%: < 60 s at 25 °C
  • Certificate: Material and Performance Test Certificate
  • ATEX Approval: II 1 G Ex ia IIC T3/T4/T6 Ga
  • IECEx Approval: II 1 G Ex ia IIC T3/T4/T6 Ga
  • Autoclavable: Yes
  • CIP: Yes
  • Steam Sterilizable: Yes
  • Operating Temperature Range: 0 to 130 °C
  • Pressure Range: 0 to 4 bar
  • Max. CO₂ Partial Pressure: 0.01 bar
  • Required Flow: ≥ 0.03 m/s
Additional Information
Specifications are subject to change without notice. For more details, refer to the Material Specification document and the Hamilton website.
See more

Catalog excerpts

OxyFerm FDA MS 120-1

OxyFerm FDA MS 120 Specification Sheet (Part/REF # 237713) Memosens technology allows upgrading an existing installation with proven Hamilton polarographic DO sensor technology. Product Specifications Sensor Family Sensor Output Electrical Connector Measurement Principle Electrochemical reduction of oxygen Measuring Range Drift at Room Temperature Oxygen Consumption Temperature Sensor Process Connection Wetted Parts Stainless Steel 1.4435 EPDM (Ethylene propylene elastomer) Silicone - FDA 21 CFR 177.2600 VMQ (Silicone elastomer) See compliance details in Material Specification document Surface Quality of Steel Electrode system Silver platinum combination Polarization Voltage and Time Serial Number Material and Performance Test Certificate ATEX Approval IECEx Approval Steam Sterilizable Operating Temperature Range

 Open the catalog to page 1
OxyFerm FDA MS 120-2

Required Flow Specifications are subject to change without notice https://www.hamiltoncompany.com/sensors/237540-1 Spec. Version

 Open the catalog to page 2

All Hamilton Process Analytics catalogs and technical brochures

  1. OxyGold G 120

    2  Pages

  2. OxyGold B 120

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.