1. Catalogs
  2. Hamilton Process Analytics
  3. Hamilton Single Use Sensors

Hamilton Single Use Sensors

Hamilton Single Use Sensors

Hamilton Single Use Sensors

Product catalog summary
Overview
Hamilton's single-use sensors are designed to integrate seamlessly into bioreactors, offering reliable and stable measurements. These sensors maintain high accuracy even after gamma irradiation and have a sufficient shelf life, making them ideal for single-use applications.
Key Features
  • Ready to Use: Pre-calibrated and pre-sterilized sensors are integrated into single-use containers.
  • Short Wet-In Time: Less than 30 minutes required.
  • Wide Range Connectivity: Compatible with existing bioreactor controllers.
  • Very Low Drift: Less than 0.1 pH per week, unaffected by changing ionic strength.
  • Reliable Technology: Proven Hamilton sensor technology.
pH and DO Sensors
  • pH Sensors: Simplified integration with existing transmitters, with easy calibration using OneFerm pH factory calibration data.
  • DO Sensors: Hamilton single-use ODO Cap Sx requires only a 1-point calibration, with high manufacturing repeatability even after gamma irradiation.
Arc Module SU
The detachable Arc Electronics stores sensor data, amplifies measurements, and outputs signals to the process control system. It supports a wide range of SU sensors and adapter cables for connectivity with existing control systems.
Single-Use Solutions
  • Integration: Arc technology provides robust, noise-free connections without traditional transmitters.
  • Measurement Variety: Adapted for single-use bag installations, covering media prep, mixing, and cell culture.
  • Design: No need for autoclaving; sensors come with weld-in style measurement elements or standard port fittings.
Technical Specifications
  • Conducell SU: Shaft lengths from 70 mm to 425 mm, with various electrical connectors and temperature sensors.
  • Measurement Principles: Includes permittivity, conductivity, and oxygen-dependent luminescence quenching.
  • Installation: Weld-in flush sensing elements for various applications.
General Requirements
  • 3rd party test data available for review.
  • Sensor elements suitable for ISO 14644 Class 7 production environment.
  • Unique calibration data for all sensor elements.
Contact Information
For more details, visit Hamilton's website or contact their offices in Switzerland or the USA.
See more

Catalog excerpts

Hamilton Single Use Sensors-2

Designed Specifically to Meet Your Single-Use Requirements SINGLE-USE True Integration Through Arc Technology A NEW WAY TO THINK ABOUT SENSOR MANAGEMENT All Hamilton single-use products include options for Arc Intelligent sensor technology. Arc converts the measurement into a robust, noise-free connection without the bulk of traditional transmitters. Choose open source digital protocol Modbus or 4–20mA signals directly into the process control system. Simplify the start of each run through wireless sensor configuration, calibration, GMP validation, and diagnostics using ArcAir software. ARC MODULE...

 Open the catalog to page 2
Hamilton Single Use Sensors-3

Solutions for Single-Use B One Vendor, All Measurements Hamilton has worked closely with single-use equipment manufacturers to understand the market needs. WIDE VARIETY OF MEASUREMENTS Whether media prep, mixing, or cell culture, each application has different sensing requirements. Hamilton’s reusable measurement technologies have been adapted for single-use bag installations. Cond SfTY pH DO Solutions for Single-Use Bioreactors DESIGNED FOR YOUR NEEDS There are no accordion-style insertion devices or probe assemblies that must be autoclaved. Single-use sensors come with either weld-in style...

 Open the catalog to page 3
Hamilton Single Use Sensors-4

OneFerm pH Single-Use Sensor Patch Solutions Incyte SU VCD Arc Wi Wireless Arc Module SU for OneFerm Label with Port Fitting for Bag Adapter (Optional) Digital Signal Integration pH Sensor Calibration Data Installation Arc Wi Wireless Incyte SU VCD Bioreactor Patch Handle Label with Bioreactor Patch Adapter (Optional) Calibration Data Criteria Description Criteria Description

 Open the catalog to page 4
Hamilton Single Use Sensors-5

Product Discussion Guide Demos? Samples? Hamilton OEM support realizes that selecting single-use measurement technology requires pre-qualification before launching to the public. Let us help by getting some basic information about your process to see if Hamilton Single-Use products can be a good fit. MECHANICAL INTEGRATION ■ Definition of SU container (bag, benchtop, size, etc.) ■ Needed Measurements ■ Sensor Geometry for Your Application ■ Documentation (Validation reports, Biocompatibility, Extractable study, etc.) CONTROLLER INTEGRATION ■ Digital Integration: Modbus RTU ■ Converters (Profibus,...

 Open the catalog to page 5

All Hamilton Process Analytics catalogs and technical brochures

  1. OxyGold G 120

    2  Pages

  2. OxyGold B 120

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.