Product Overview: The EasyFerm Plus pH sensor is a widely used product by Hamilton for pharmaceutical applications, particularly where autoclave and SIP (Sterilization In Place) are frequently performed.
Specifications:
  • Sensor Family: EasyFerm Plus
  • Parameter: pH
  • Length: 120 mm
  • Electrical Connector: S8
  • Measurement Principle: Combination electrode; pH potential measured against reference
  • Measuring Range: pH 0 to 14
  • Sensitivity: 57 to 59 mV/pH at 25 °C
  • Zero Point: 0 ± 20 mV
  • pH Glass: Hamilton Type PHI Glass
  • pH Glass Resistance: Moderate
  • Membrane Shape: Spherical
  • Diaphragm: HP-Coatramic
  • Number of Diaphragms: 1
  • Electrolyte: Pressurized Phermlyte
  • Reference System: Hamilton Everef-F, Silver ion barrier included
  • Liquid Earth: No
  • Temperature Sensor: No
  • Diameter: 12 mm
  • Process Connection: PG13,5
  • Wetted Parts: Glass, Ceramic, EPDM (Ethylene propylene elastomer)
  • O-ring Material: FDA 21 CFR 177.2600; EG 1935/2004; USP <87>; USP <88> Class VI (121 °C)
  • Serial Number: Yes
  • Recommended Storage: Hamilton Storage Solution or 3 M KCl
  • Certificate: Yes, with measured values in Buffer pH 4.01 and pH 7.00
  • ATEX Approval: II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
  • IECEx Approval: II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
  • Autoclavable: Yes
  • CIP: Yes
  • Steam Sterilizable: Yes
  • Operating Temperature Range: 0 to 140 °C
  • Sample Minimum Conductivity: 100 µS/cm
  • Pressure Range: 0 to 6 bar
Additional Information: Specifications are subject to change without notice. For more details, visit the Hamilton website.
See more

Catalog excerpts

EasyFerm Plus PHI S8 120-1

EasyFerm Plus PHI S8 120 Specification Sheet (Part/REF # 238633-1213) The EasyFerm Plus pH sensor is Hamilton's most popular product for pharmaceutical applications where autoclave and SIP are frequently performed. Product Specifications Sensor Family EasyFerm Plus Electrical Connector Measurement Principle Combination electrode; pH potential measured against reference Measuring Range Zero Point Hamilton Type PHI Glass Membrane Shape Pressurized Phermlyte Reference System Hamilton Everef-F, Silver ion barrier included Liquid Earth Temperature Sensor Process Connection Wetted Parts Glass Ceramic EPDM (Ethylene propylene elastomer) O-ring Material Serial Number Recommended Storage Hamilton Storage Solution or 3 M KCl Yes, with measured values in Buffer pH 4.01 and pH 7.00 ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db

 Open the catalog to page 1
EasyFerm Plus PHI S8 120-2

Steam Sterilizable Operating Temperature Range Specifications are subject to change without notice https://www.hamiltoncompany.com/sensors/238633-1213

 Open the catalog to page 2

All Hamilton Process Analytics catalogs and technical brochures

  1. OxyGold G 120

    2  Pages

  2. OxyGold B 120

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.