1. Catalogs
  2. Hamilton Process Analytics
  3. EasyFerm Plus ORP Arc 120

EasyFerm Plus ORP Arc 120

EasyFerm Plus ORP Arc 120

EasyFerm Plus ORP Arc 120

Product catalog summary
Product Overview
The EasyFerm Plus ORP Arc 120 sensor is designed for process control and monitoring in bioprocesses, offering versatility with various sensor length options. It utilizes Arc technology for enhanced performance.
Specifications
  • Sensor Family: EasyFerm Plus
  • Parameter: ORP
  • Sensor Output: Arc: Modbus, 4 to 20 mA
  • Length: 120 mm
  • Electrical Connector: VP8
  • Measurement Principle: Combination electrode; ORP potential measured against reference
  • Measuring Range: -1500 mV to +1500 mV
  • ORP Element: Pt ring
  • Membrane Shape: Spherical
  • Diaphragm: HP-Coatramic
  • Number of Diaphragms: 1
  • Electrolyte: Pressurized Phermlyte
  • Reference System: Hamilton Everef-F, Silver ion barrier included
  • Liquid Earth: Yes
  • Temperature Sensor: NTC 22 kOhm
  • Configurable Values: ORP: mV; Temperature: °C, K, °F
  • Diameter: 12 mm
  • Process Connection: PG13,5
  • Wetted Parts: Platinum, Glass, Ceramic, EPDM
  • Analog Interface 1: 4 to 20 mA, programmable
  • Analog Interface 2: 4 to 20 mA for Temp., programmable
  • Analog Interfaces: Not galvanically isolated; pulse width modulation 3.5 kHz
  • Baud Rate: 4800, 9600, 19200, 38400, 57600, 115200 Bd
  • Operating Voltage: 7 to 30 VDC max. 150 mW
  • Serial Number: Yes
  • Recommended Storage: Hamilton Storage Solution or 3 M KCl
  • Certificate: Yes, with measured value in ORP buffer +475 mV
  • ATEX Approval: No
  • IECEx Approval: No
  • Autoclavable: Yes, max. Temperature 130 °C
  • CIP: Yes
  • Steam Sterilizable: Yes, max. Temperature 140 °C
  • Operating Temperature Range: Analog interface: 0 to 110 °C; Digital interface: 0 to 140 °C
  • Sample min Conductivity: 100 µS/cm
Additional Information
Specifications are subject to change without notice. For more details, visit the Hamilton Company website.
See more

Catalog excerpts

EasyFerm Plus ORP Arc 120-1

EasyFerm Plus ORP Arc 120 Specification Sheet (Part/REF # 243050) Arc technology with a variety of sensor length options make this versatile sensor ideal for process control and monitoring in bioprocesses. Product Specifications Sensor Family EasyFerm Plus Sensor Output Electrical Connector Measurement Principle Combination electrode; ORP potential measured against reference Measuring Range Membrane Shape Pressurized Phermlyte Reference System Hamilton Everef-F, Silver ion barrier included Liquid Earth Temperature Sensor Configurable Values Process Connection Wetted Parts Platinum Glass Ceramic EPDM (Ethylene propylene elastomer) Galvanically not isolated; pulse width modulation 3.5 kHz Baud Rate Operating Voltage Serial Number Recommended Storage Hamilton Storage Solution or 3 M KCl Yes, with measured value in ORP buffer +475 mV ATEX Approval

 Open the catalog to page 1
EasyFerm Plus ORP Arc 120-2

IECEx Approval Steam Sterilizable Operating Temperature Range Analog interface: 0 to 110 °C; Digital interface: 0 to 140 °C Specifications are subject to change without notice https://www.hamiltoncompany.com/sensors/243050 Spec. Version

 Open the catalog to page 2

All Hamilton Process Analytics catalogs and technical brochures

  1. OxyGold G 120

    2  Pages

  2. OxyGold B 120

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.