1. Catalogs
  2. Hamilton Process Analytics
  3. EasyFerm Bio HB Arc 120

EasyFerm Bio HB Arc 120

EasyFerm Bio HB Arc 120

EasyFerm Bio HB Arc 120

Product catalog summary
Product Overview
The EasyFerm Bio HB Arc 120 is an intelligent sensor designed to securely store sensor data and output measurement information directly to control systems. It is part of the EasyFerm Bio sensor family and is used for pH measurement.

Specifications
  • Parameter: pH
  • Length: 120 mm
  • Electrical Connector: VP8
  • Sensor Output: Arc: Modbus, 4 to 20 mA
  • Measurement Principle: Combination electrode; pH potential measured against reference
  • Measuring Range: pH 0 to 14
  • Sensitivity: 57 to 59 mV/pH at 25 °C
  • Zero Point: 0 ± 20 mV
  • pH Glass: Hamilton type HB glass
  • pH Glass Resistance: Moderate
  • Membrane Shape: Spherical
  • Diaphragm: HP-Coatramic
  • Number of Diaphragms: 1
  • Electrolyte: Pressurized Foodlyte
  • Reference System: Hamilton Everef-F, Silver ion barrier included
  • Temperature Sensor: NTC 22 kOhm
  • Configurable Values: pH: pH, mV; Temperature: °C, K, °F
  • Diameter: 12 mm
  • Process Connection: PG13,5
  • Wetted Parts: Glass, VMQ (Silicone elastomer)
  • O-ring Material: FDA 21 CFR 177.2600; EG 1935/2004; USP <87>; USP <88> Class VI (121 °C)
  • Analog Interface 1: 4 to 20 mA for pH, programmable
  • Analog Interface 2: 4 to 20 mA for Temp., programmable
  • Analog Interface 1 and 2: Galvanically not isolated; pulse width modulation 3.5 kHz
  • Digital Interface: RS485 Modbus (max. 31 addresses)
  • Baud Rate: 4800, 9600, 19200, 38400, 57600, 115200 Bd
  • Operating Voltage: 7 to 30 VDC max. 150 mW
  • Serial Number: Yes

Additional Information
  • Specifications are subject to change without notice.
  • Recommended Storage: Hamilton Storage Solution or 3 M KCl
  • Certificate: Yes, with measured values in Buffer pH 4.01 and pH 7.00
  • ATEX Approval: No
  • Autoclavable: Yes, max. Temperature 130 °C
  • CIP: Yes
  • Steam Sterilizable: Yes, max. Temperature 140 °C
  • Operating Temperature Range: Analog interface: 0 to 110 °C; Digital interface: 0 to 140 °C
  • Sample min Conductivity: 100 µS/cm
  • Pressure Range: 0 to 6 bar
See more

Catalog excerpts

EasyFerm Bio HB Arc 120-1

EasyFerm Bio HB Arc 120 Specification Sheet (Part/REF # 243632-2313) Arc intelligent sensor technology securely stores your sensor data and outputs your measurement information directly to the control system. Product Specifications Sensor Family Electrical Connector Sensor Output Measurement Principle Combination electrode; pH potential measured against reference Measuring Range Zero Point Hamilton type HB glass Membrane Shape Pressurized Foodlyte Reference System Hamilton Everef-F, Silver ion barrier included Temperature Sensor Configurable Values Process Connection Wetted Parts Glass VMQ (Silicone elastomer) O-ring Material Galvanically not isolated; pulse width modulation 3.5 kHz Digital Interface Baud Rate Operating Voltage Serial Number

 Open the catalog to page 1
EasyFerm Bio HB Arc 120-2

Recommended Storage Hamilton Storage Solution or 3 M KCl Certificate Yes, with measured values in Buffer pH 4.01 and pH 7.00 Steam Sterilizable Yes, max. Temperature 140 °C Operating Temperature Range Analog interface: 0 to 110 °C; Digital interface: 0 to 140 °C Specifications are subject to change without notice Spec. Version C

 Open the catalog to page 2

All Hamilton Process Analytics catalogs and technical brochures

  1. OxyGold G 120

    2  Pages

  2. OxyGold B 120

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.