Dencytee RS485 120

Dencytee RS485 120

Dencytee RS485 120

Product catalog summary
Product Overview: The Dencytee RS485 120 sensor measures Total Cell Density (TCD) based on optical density or turbidity at NIR wavelengths. It is part of the Dencytee Arc sensor family and features a wide measuring range.
Specifications:
  • Sensor Family: Dencytee Arc
  • Length: 120 mm
  • Parameter: Total Cell Density
  • Electrical Connector: VP8
  • Sensor Output: Arc: Modbus
  • Measurement Principle: Transmission and Reflection with temperature compensation, daylight filter, and subtraction
  • Wavelength: 860 nm
  • Measuring Range: 0-200 g/l cell dry weight yeast, 0-4 AU, 0-30,000 NTU
  • Accuracy at 25°C: Resolution: 0.05 g/l (0-10 g/l); 0.5% (>10 g/l) cell dry weight yeast
  • Reproducibility: ±1%
  • Linearity: < ±1% of respective measuring range
  • Temperature Sensor: NTC 22 kOhm
  • Configurable Values: TCD: PCV, AU, arb. Unit, NTU, g/l, CFU, e6 cells/ml, OD; Temperature: K, °C, °F
  • Diameter: 12 mm
  • Process Connection: PG13,5
  • Wetted Parts: Stainless Steel 1.4435, Sapphire glass, EPDM
  • Surface Quality of Steel: Ra < 0.4 µm (N5)
  • Digital Interface: RS485 Modbus (max. 31 addresses)
  • Baud Rate: 4800, 9600, 19200, 38400, 57600, 115200 Bd
  • Operating Voltage: +10 to +27 VDC
  • Optical Path Length: 5 mm
  • Serial Number: Yes
  • Certificate: Yes, in water and at 10,000 NTU Standard
  • ATEX Approval: No
  • IECEx Approval: No
  • Autoclavable: Yes
  • CIP: Yes
  • Steam Sterilizable: Yes, max. Temperature 140°C
  • Storage Conditions: -20°C to 45°C
  • Operating Temperature Range: 0 to 140°C; no TCD reading above 80°C
  • Pressure Range: 0 to 12 bar
  • Protection Rating: IP 68
Additional Information: Specifications are subject to change without notice. For more details, visit the Hamilton Company website.
See more

Catalog excerpts

Dencytee RS485 120-1

Dencytee RS485 120 Specification Sheet (Part/REF # 10064919-11) Total cell density (TCD) measurement by the Dencytee sensor is based on the optical density, or the turbidity of a suspension at NIR wavelengths. The Dencytee sensor has a wide measuring range of TCD. Product Specifications Sensor Family Total Cell Density Electrical Connector Sensor Output Measurement Principle Transmission and Reflection (including temperature compensation, daylight filter and subtraction) Measuring Range e.g. 0-200g/l cell dry weight yeast 0-4 AU 0-30'000 NTU Resolution: 0.05 g/l (0-10 g/l); 0.5 % (> 10 g/l) cell dry weight yeast Reproducibility: ± 1 % Linearity: < ± 1% of respective measuring range (specific to application with off-line correlation) Temperature Sensor Configurable Values TCD: PCV, AU, arb. Unit, NTU, g/l, CFU, e6 cells/ml, OD Temperature: K, °C, °F Process Connection Wetted Parts Stainless Steel 1.4435 Sapphire glass EPDM (Ethylene propylene elastomer) See compliance details in Material Specification document Surface Quality of Steel Digital Interface Baud Rate Operating Voltage Optical Path Length Serial Number ATEX Approval IECEx Approval

 Open the catalog to page 1
Dencytee RS485 120-2

Steam Sterilizable Storage Conditions Operating Temperature Range 0 to 140 °C; the sensor provides no TCD reading above 80 °C. Protection Rating Specifications are subject to change without notice https://www.hamiltoncompany.com/sensors/10064919-11 Spec. Version

 Open the catalog to page 2

All Hamilton Process Analytics catalogs and technical brochures

  1. OxyGold G 120