ORCA-FUSION C14440-20UP - 2

Low-light Imaging The ORCA-Fusion, built from the sensor up, balances the complex nuances of camera features to provide beautiful images and robust data at all lights levels, but especially in tough low-light conditions. The exceptionally low and highly uniform readout noise of the ORCA-Fusion means that when the sample emits even just a handful of photons, either by default or by experimental design, they are not lost in the noise, but detected and reliably quantified. After all, when you want to hear a whisper it’s best to be in a quiet place. READOUT NOISE HIGH RESOLUTION PIXEL SIZE...

Open the catalog to page 2
ORCA-FUSION C14440-20UP - 4

APPLICATION HIGHLIGHT Genetically Encoded Voltage Imaging Below: Spontaneous neural activity in a hippocampal neuron, captured at 828 Hz and reported by the fluorescent voltage indicator SomArchon, (Piatkevich et al., 2019, bioRxiv). These images represent the average intensity of 100 frames in spiking (A) and non-spiking (B) states. (A) Spiking window (100 frame average) (B) Non-spiking window (100 frame average) FRAMES 1 Frame 152 (pre-spike) Above: The same data showing individual frames at points before, during, and after a single spike. Image courtesy of Han Lab, Boston University....

Open the catalog to page 4
ORCA-FUSION C14440-20UP - 5

The Neural Activity Holy Grail Imaging neuronal activity using voltage sensitive indicators is a scientific quest that challenges the limits of neuroscience and compels advances in chemistry and protein engineering, as well as live animal, deep tissue, high speed and computational imaging. Scientists are making great progress in each of these areas and see a bright future for this burgeoning field (Please see the “References” below for a sampling of this work). A huge hurdle is finding imaging technology that can deliver the necessary speed, sensitivity and field of view, while also...

Open the catalog to page 5
ORCA-FUSION C14440-20UP - 6

HOW TO DETECT A WHISPER OF LIGHT What is Read Noise? To understand the significance of read noise in imaging, it’s first necessary to review how digital images are formed in both CCD and CMOS. The basic principle is the same: incoming photons are converted to photo (electrons) via the photoelectric effect in the sensitive layer of the silicon substrate. This electron charge is next converted to a voltage via floating diffusion node (FD), amplified via a source follower and then digitized through an analog to digital converter (ADC). CCD and CMOS differ in the on-chip location where each of...

Open the catalog to page 6
ORCA-FUSION C14440-20UP - 7

Temporal Dark Read Noise 3 Read noise map comparison READ NOISE (electrons) ORCA-Fusion Ultra-quiet Scan Standard Scan Fast Scan Temporal Dark Read Noise Distribution 106 105 ORCA-Fusion Standard Scan ORCA-Fusion Fast Scan ORCA-Fusion Ultra-quiet Scan 0.73 e- 0.57 e- TEMPORAL DARK READ NOISE (electrons) The entire read out process of detecting, converting, moving and digitizing the photoelectrons introduces temporal noise, termed “read noise” into the amplification and digitization process. Since in a CCD this process happens serially through a single read out chain, the read noise of each...

Open the catalog to page 7
ORCA-FUSION C14440-20UP - 8

ENABLING QUANTITATIVE RELIABILITY Dark Signal Non-Uniformity (DSNU), Dark Offset A camera is a scientific instrument because it is designed for quantitative measurements of intensity. To accurately measure image intensity there are three key camera parameters that must be calibrated by the manufacturer: dark signal non-uniformity (DSNU), photo-response non-uniformity (PRNU) and linearity. Dark Offset Image DARK OFFSET COMPARISON ABSOLUTE ERROR (Pixel Signal / Mean Signal) (electrons) Ultra-quiet Scan Standard Scan Standard Scan Mean subtracted averaged dark image from 20,000 frames 2,000 ×...

Open the catalog to page 8
ORCA-FUSION C14440-20UP - 9

Linearity A linearly responsive camera will output a digital intensity value that is linearly proportional to the amount of input photons. In all current front and back illuminated sCMOS Gen II sensors, the analog signal generated by the incoming photons is converted to digital units by two separate digitizers, one for low light and one for high light. This pixel design requires matching the slopes of the two analog-to-digital converters (ADCs) to output linear 16 bit images. Design engineers must pay careful attention to the point of overlap of the two ADCs to make this low and high light...

Open the catalog to page 9
ORCA-FUSION C14440-20UP - 10

HAMAMATSU ORCA-FUSION Image examples A. Regenerated lamprey spinal cord. (E. Guadarrama and J. Morgan, MBL). B. Plant tissue culture induced to make xylem. (CT. Baskin, UMass Amherst, R. Oldenbourg, MBL). C. Regenerated lamprey spinal cord. (E. Guadarrama and J. Morgan, MBL) Typical frame rates (frames/s) READOUT MODE Scan mode AREA READOUT MODE Fast scan CoaXPress (16 bit) LIGHTSHEET READOUT MODE Standard scan Ultra-quiet scan Fast scan The faster frame rates are available at 8 bit and 12 bit Typical frame rates at 2×2 binning (frames/s) READOUT MODE Scan mode AREA READOUT MODE LIGHTSHEET...

Open the catalog to page 10
ORCA-FUSION C14440-20UP - 11

Readout noise *1 Fast scan Standard scan Ultra-quiet scan 1.4 electrons, rms 1.0 electrons, rms 0.7 electrons, rms Full well capacity *1 Dynamic range *1 Conversion factor *1 Cooling Temperature Forced-air cooled Water cooled Water cooled (Max cooling) -5 ˚C (Ambient temperature: +25 ˚C) -5 ˚C (Water temperature: +25 ˚C) Less than -15 ˚C *1, *8 Dark current *1, *3 Cooling temperature: -5 ˚C Cooling temperature: -15 ˚C Dark offset 0.5 electrons/pixel/s 0.2 electrons/pixel/s 100 counts Dark signal non-uniformity (DSNU) *1 Photo response non-uniformity *1 At 7500 electrons (PRNU) Linearity...

Open the catalog to page 11
ORCA-FUSION C14440-20UP - 12

CAMERA SPECS LOW NOISE AND EXCEPTIONAL READOUT NOISE UNIFORMITY READOUT NOISE HIGH SPEED Ultra-quiet Scan HIGH RESOLUTION PIXEL SIZE DYNAMIC RANGE QUANTUM EFFICIENCY (%) For Technical Note 80 ORCA is registered trademark of Hamamatsu Photonics K.K. (France, Germany, Japan, U.K., U.S.A.) 70 Product and software package names noted in this documentation are trademarks or registered trademarks of their respective manufacturers. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult your local sales...

Open the catalog to page 12

All HAMAMATSU catalogs and technical brochures

  1. SPAD MODULES

    5 Pages

  2. LIGHTNINGCURE

    29 Pages

  3. C13410-06A

    4 Pages

  4. PMA-12

    8 Pages

  5. L12542

    4 Pages

  6. FLAT EXCIMER

    16 Pages

  7. L15208-01

    3 Pages

  8. L15856-01

    3 Pages

  9. L14001-01

    2 Pages

  10. L14351-02

    4 Pages

  11. GC-113A

    2 Pages

  12. DIUTHAME

    12 Pages

  13. J12853

    2 Pages

  14. J12432-01

    2 Pages

  15. C15780-401

    4 Pages

  16. H15460-40

    4 Pages

  17. R14755U-100

    2 Pages

  18. LIGHT SOURCES

    23 Pages

  19. PHOTOTUBES

    8 Pages

  20. PSD

    8 Pages

  21. Photo IC

    8 Pages

  22. Image Sensors

    48 Pages

  23. Si Photodiodes

    48 Pages

  24. Si APD

    16 Pages

  25. FLOW CELLS

    4 Pages

  26. Si photodiodes

    41 Pages

Archived catalogs