1. Catalogs
  2. HAMAMATSU
  3. ORCA-Fusion BT
video corpo

ORCA-Fusion BT
1 /9Pages

ORCA-Fusion BT

ORCA-Fusion BT
1 /9Pages

Catalog excerpts

ORCA-Fusion BT-2

Ultra-low readout noise Fast frame S E N O I rates and back-thin boosted high See what you’ve been missing. Capture visually stunning high S/N images from Resolve high-speed temporal events. Computationally analyze images with confidence.

 Open the catalog to page 2
ORCA-Fusion BT-3

HIGH SPEED HIGH RESOLUTION

 Open the catalog to page 3
ORCA-Fusion BT-4

Back-thin Boosted QE for Maximum Photon Collection 100 QUANTUM EFFICIENCY (%) Minimal and Highly Uniform Readout Noise Results in Maximum Low Light Detection 1,000,000 (Ultra-quiet) (Standard) (Fast) ORCA-Fusion BT: Detection Optimized The ORCA-Fusion represented a leap forward from “Gen II” sCMOS, providing significant advantages in readout noise and uniformity for improved image quality. The ORCA-Fusion BT is the natural technological progression. The unique combination of back-thin boosted QE plus low noise and high uniformity delivers the ultimate in camera performance, versatility and sensitivity...

 Open the catalog to page 4
ORCA-Fusion BT-5

1. Mouse kidney imaged on a 3i Cleared Tissue LightSheet System with ORCA-Fusion BT. Sample courtesy of Dr. Bo Shen, University of Texas Southwestern Medical Center. 2. Frontal view of whole mouse brain labeled with Thy1-GFP imaged on a 3i Cleared Tissue LightSheet System with ORCA-Fusion BT. Sample courtesy of Dr. Hu Zhao, Texas A&M College of Dentistry. 3. Lateral view of whole mouse brain labeled with Thy1-GFP imaged on a 3i Cleared Tissue LightSheet System with ORCA-Fusion BT. Sample courtesy of Dr. Hu Zhao, Texas A&M College of Dentistry. 4. Brainstem neurons in whole mouse brain labeled...

 Open the catalog to page 5
ORCA-Fusion BT-6

Super resolution image of fixed Cos7 cells labeled with Tubulin-AF647. Image acquired using Olympus microscope IX83 with 100x TIRF 1.50 and ZDC 2 + Abbelight SAFe 360 with ORCA-Fusion BT camera for a FOV of 85 x 85 µm2. Localization precision of 10nm/10nm/15nm (x,y,z). Image courtesy of Abbelight. Frames per second (fps) READOUT MODE AREA READOUT MODE Scan mode Fast scan LIGHTSHEET READOUT MODE Standard scan Ultra-quiet scan Fast scan *1 Faster frame rates achievable at 8 and 12 bit. Typical FPS with 2×2 binning READOUT MODE AREA READOUT MODE LIGHTSHEET READOUT MODE Fast scan Scan mode Standard...

 Open the catalog to page 6
ORCA-Fusion BT-7

Custom designed with research in mind L I V E - C E L L No one camera can delivery perfect performance for every application. But the ORCA-Fusion BT comes close. This custom sensor was created to make the most L O W - L demanding imaging applications easy. Few photons? No problem. Fast live cell I G H T events? Turn up the speed. Require reliable raw images for quantitative analysis? Compute with individualized camera noise calibration data. W I D E - F I E L D F L U O R E S C E N C E M I C R O S C O P Y Q U A N T I T A T I V E A E T R has K I N tell M O L E C U L dim sampleA C secrets toG but...

 Open the catalog to page 7
ORCA-Fusion BT-8

Read noise *1 Fast scan Standard scan Ultra-quiet scan 1.6 electrons, rms 1.0 electrons, rms 0.7 electrons, rms Full well capacity *1 Dynamic range *1, *2, *4 Conversion factor *1, *2 Cooling Temperature With forced-air Water cooled Water cooled (Max cooling) -8 ˚C (Ambient temperature: +25 ˚C) -8 ˚C (Water temperature: +25 ˚C) Less than -15 ˚C (Ambient temperature: +20 ˚C, water temperature: +20 ˚C) Dark current *1, *3 @ -8 ˚C @ -15 ˚C Dark offset 1.0 electrons/pixel/second 0.7 electrons/pixel/second 100 counts Typical value Dark signal non-uniformity (DSNU) *1,*4 0.06 electrons rms in Ultra-quiet...

 Open the catalog to page 8
ORCA-Fusion BT-9

CAMERA SPECS LOW N O I S E A N D E XC E PT I O N A L READOUT NOISE UNIFORMITY WITH HIGH QE Ultra-quiet Scan HIGH SPEED HIGH RESOLUTION PIXEL SIZE DYNAMIC RANGE Ultra-quiet Scan Ultra-quiet Scan HAMAMATSU PHOTONICSBoostedwww.hamamatsu.com Photon Collection Back-thin K.K. QE for Maximum Systems Division 100 812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-433-8031, E-mail: [email protected] QUANTUM EFFICIENCY (%) U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, NJ 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail:...

 Open the catalog to page 9

All HAMAMATSU catalogs and technical brochures

  1. SPAD MODULES

    5  Pages

  2. LIGHTNINGCURE

    29  Pages

  3. C13410 series

    4  Pages

  4. C13410-06A

    4  Pages

  5. PMA-12

    8  Pages

  6. L12542

    4  Pages

  7. FLAT EXCIMER

    16  Pages

  8. L15208-01

    3  Pages

  9. L15856-01

    3  Pages

  10. L14001-01

    2  Pages

  11. L11854-336-05

    2  Pages

  12. L14351-02

    4  Pages

  13. GC-113A

    2  Pages

  14. DIUTHAME

    12  Pages

  15. J12853

    2  Pages

  16. J12432-01

    2  Pages

  17. J10919 SERIES

    2  Pages

  18. C15780-401

    4  Pages

  19. H15460-40

    4  Pages

  20. R14755U-100

    2  Pages

  21. C13398 series

    5  Pages

  22. LIGHT SOURCES

    23  Pages

  23. PHOTOTUBES

    8  Pages

  24. PSD

    8  Pages

  25. Photo IC

    8  Pages

  26. Image Sensors

    48  Pages

  27. Si Photodiodes

    48  Pages

  28. Si APD

    16  Pages

  29. FLOW CELLS

    4  Pages

  30. Si photodiodes

    41  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.