Catalog excerpts

Infrared Detectors-1

Selection guide - March 2013 INFRARED DETECTORS Covering a broad spectral range in the infrared region INFRARED DETECTORS HAMAMATSU PHOTONICS K.K.

 Open the catalog to page 1
Infrared Detectors-2

Infrared detectors Infrared detectors are widely used in diverse field including measurement, analysis, indust r y, c o m m u n i c a t i o n , a g r i c u l tu r e , m e d i c i n e , physical and chemical science, astronomy and s p a c e . Ba s e d o n l o n g ex p e r i e n c e i nvo l v i n g photonic technology, HAMAMATSU provides a wide variety of infrared detectors in order to meet a large range of application needs. In addition to the st andard devices listed in this catalog, custom devices are also available on request. Please feel free to contact the nearest sales office in your area....

 Open the catalog to page 2
Infrared Detectors-3

InAs/InAsSb/InSb photovoltaic detectors, InSb photoconductive detectors MCT (HgCdTe) photoconductive/ photovoltaic detectors Thermopile detectors (Si thermal detectors) Photon drag detector Two-color detectors Accessories for infrared detectors Infrared detectors

 Open the catalog to page 3
Infrared Detectors-4

Infrared detectors HAMAMATSU infrared detectors Spectral response range (μm) Product name • Short wavelength enhanced type • Can detect light from 0.5 μm • Standard type • High-speed response, high sensitivity, low dark current • Available various types of photosensitive areas, arrays and packages • Types for spectrophotometry and WDM monitor, and high-speed type available Spectral response range (μm) Product name • For NIR spectroscopy • Available TE-cooled type • For optical measurement in the band of water content absorption (1.9 μm) • Available TE-cooled type • For optical measurement around...

 Open the catalog to page 4
Infrared Detectors-5

Spectral response of HAMAMATSU infrared detectors (typical example) 1014 Photovoltaic detectors Photoconductive detectors Si thermal detectors 1013 Short wavelength enhanced type InGaAs (25 °C) Long wavelength type InGaAs (-196 °C) Long wavelength type InGaAs (25 °C) 109 Thermopile detecter When using infrared detectors, the following points should be taken into consideration for making a device selection. Law of black body radiation (Planck's law) 104 As can be seen from the figure above, HAMAMATSU provides a variety of infrared detectors with different spectral response characteristics. It...

 Open the catalog to page 5
Infrared Detectors-6

InGaAs PIN photodiodes Short wavelength enhanced type (Typ. Ta=25 °C, unless otherwise noted) Spectral response range λ (μm) Peak sensitivity wavelength λp (μm) Option (sold separately) Standard type Metal package Various photosensitive area sizes are available. Type no. G8605-25 * Low PDL (polarization dependent loss) type 1 Infrared detectors Option (sold separately) Peak sensitivity wavelength λp (μm) (Typ. Ta=25 °C, unless otherwise noted) Spectral response range λ (μm)

 Open the catalog to page 6
Infrared Detectors-7

InGaAs PIN photodiodes Ceramic package Photosensitive area Spectral response range λ (μm) Peak sensitivity wavelength λp (μm) 1000 Surface mount type ceramic Surface mount type These InGaAs PIN photodiodes are assembled on a small ceramic base originally developed for laser diode monitoring. The G8941 series InGaAs photodiodes use a front-illuminated sensor chip, while the G9230-01 uses a back-illuminated sensor chip mounted on a base without wire bonding to allow an optical fiber to be set in close proximity. Photosensitive area Spectral response Peak sensitivity Cutoff frequency wavelength...

 Open the catalog to page 7
Infrared Detectors-8

Long wavelength type Peak sensitivity wavelength: 1.75 μm These are suitable for optical measurement around 1.7 μm. Type no. Spectral response range λ (μm) (Typ. Ta=25 °C, unless otherwise noted) Peak sensitivity wavelength λp (μm) Option (sold separately) Peak sensitivity wavelength: 1.95 μm These are suitable for optical measurement in the 1.9 μm band such as water absorption. Type no. Spectral response range λ (μm) Peak sensitivity wavelength λp (μm) Option (sold separately) (Typ. Ta=25 °C, unless otherwise noted) Infrared detectors

 Open the catalog to page 8
Infrared Detectors-9

InGaAs PIN photodiodes Peak sensitivity wavelength: 2.3 μm These are suitable for use in NIR (near infrared) spectroscopy. Type no. Spectral response range λ (μm) (Typ. Ta=25 °C, unless otherwise noted) Peak sensitivity wavelength λp (μm) Option (sold separately) Spectral response G12182 series Infrared detectors

 Open the catalog to page 9
Infrared Detectors-10

Infrared detector modules with preamp These modules consist of an InGaAs PIN photodiode assembled with matched preamplifier, and operate by connecting a DC power supply. Photosensitive area Peak sensitivity wavelength λp Measurement condition Element temperature (°C) EN 61326-1 Class B Note: Supplied with a power supply cable Spectral response Infrared detectors

 Open the catalog to page 10
Infrared Detectors-11

InGaAs PIN photodiodes Image sensors, photodiode arrays InGaAs linear image sensors for spectrophotometry One-stage TE-cooled types can be cooled down to -10 °C and cover a spectral range from 0.9 to 1.67 μm. Type no. Applicable driver circuit (sold separately) Defective pixels Photosensitive area Spectral response range λ (μm) Pixel pitch Output can be obtained from all pixels since there are no defective pixels. Suitable for precision measurement. Type no. Defective pixels Applicable driver circuit (sold separately) Photosensitive area Spectral response range λ (μm) Pixel pitch Two-stage TE-cooled...

 Open the catalog to page 11
Infrared Detectors-12

High-speed type InGaAs linear image sensors These are high-speed linear image sensors suitable for industrial and measurement equipment. Type no. Photosensitive area Defective pixels Applicable driver circuit (sold separately) Spectral response range λ (μm) Pixel pitch These are 1024 pixels, high-speed NIR linear image sensors designed for applications such as foreigh object screening and medical diagnostic equipment where a multichannel high-speed line rate is required. Type no. Pixel pitch Spectral response range λ (μm) Defective pixels Applicable driver circuit (sold separately) These linear...

 Open the catalog to page 12

All HAMAMATSU catalogs and technical brochures

  1. SPAD MODULES

    5  Pages

  2. LIGHTNINGCURE

    29  Pages

  3. C13410 series

    4  Pages

  4. C13410-06A

    4  Pages

  5. PMA-12

    8  Pages

  6. L12542

    4  Pages

  7. FLAT EXCIMER

    16  Pages

  8. L15208-01

    3  Pages

  9. L15856-01

    3  Pages

  10. L14001-01

    2  Pages

  11. L11854-336-05

    2  Pages

  12. L14351-02

    4  Pages

  13. GC-113A

    2  Pages

  14. DIUTHAME

    12  Pages

  15. J12853

    2  Pages

  16. J12432-01

    2  Pages

  17. J10919 SERIES

    2  Pages

  18. C15780-401

    4  Pages

  19. H15460-40

    4  Pages

  20. R14755U-100

    2  Pages

  21. C13398 series

    5  Pages

  22. LIGHT SOURCES

    23  Pages

  23. PHOTOTUBES

    8  Pages

  24. PSD

    8  Pages

  25. Photo IC

    8  Pages

  26. Image Sensors

    48  Pages

  27. Si Photodiodes

    48  Pages

  28. Si APD

    16  Pages

  29. FLOW CELLS

    4  Pages

  30. Si photodiodes

    41  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.