Hamamatsu Photonics offers a wide range of infrared detectors for applications in measurement, analysis, industry, communication, agriculture, medicine, science, astronomy, and space. The catalog includes both standard devices and custom solutions.
Types of Infrared Detectors
  • InGaAs PIN Photodiodes: Suitable for optical measurements around 1.7 μm, offering high-speed response and low dark current.
  • Pbs/PbSe Photoconductive Detectors: Operate at room temperature for applications like radiation thermometers, detecting wavelengths up to 5.2 μm.
  • InAs/InAsSb/InSb Photovoltaic Detectors: Ideal for high-speed applications in the 3 to 5 μm atmospheric window.
  • MCT (HgCdTe) Detectors: Provide a wide spectral response range with cooling options.
  • Thermopile Detectors: Generate force proportional to infrared light energy, suitable for the 5 μm band.
  • Two-color Detectors: Use two detectors with different spectral responses on the same axis.
  • Photon Drag Detector: High-speed, high-sensitivity detector for CO2 laser detection in the 10 μm band.
Key Considerations for Detector Selection
  • Object Temperature: Radiating energy distribution changes with temperature.
  • Cooling: Options include thermoelectric coolers and cryogenic dewars.
  • Photosensitive Area and Elements: Various sizes and multi-element arrays available.
  • Response Speed: Varies by detector type, affected by cooling.
  • Spectral Response: Cooling shifts spectral response, varying by detector type.
Product Specifications
Detailed specifications include cooling options, photosensitive area sizes, spectral response ranges, peak sensitivity wavelengths, cutoff frequencies, and package types.
Thermopile Detectors
  • T11262-01: High-sensitivity single-element detector for gas analysis, with a spectral response of 3 to 5 μm.
  • T11722-01: Dual-element detector for CO2 detection, with band-pass filters at 3.9 μm and 4.3 μm.
Two-Color Detectors
Combine two sensors with different spectral responses, available in cooled versions for precision.
Photon Drag Detector
The B749 model is used for CO2 laser detection, with peak sensitivity at 10.6 μm.
Accessories
  • Temperature Controllers: For TE-cooled detectors, with settings from -30 to +20 °C.
  • Heatsinks: Offer various cooling capacities for TE-cooled detectors.
  • Chopper: Provides frequencies from 115 to 380 Hz.
  • Amplifiers: Low noise, suitable for various detectors, with specific power requirements.
Key Specifications
  • Photosensitive Area: Varies by model, with typical dimensions provided.
  • Spectral Response Range: Detailed for each detector, highlighting applicable wavelengths.
  • Cooling Options: Non-cooled and TE-cooled options available.
Specifications
Specifications for amplifiers include input impedance, voltage gain, frequency response, and more, designed for specific detector types.
Procedures and Recommendations
Ensure compatibility of bias current with detectors before purchase. Consult the manufacturer for unlisted detectors or multi-element detectors.
Norms and Standards
Amplifiers comply with EN 61326-1 Class B standards. Adherence to maximum ratings is crucial.
Technical Terms
Definitions provided for terms like dark resistance, dark current, and quantum efficiency.
Warranty and Liability
Includes warranty information, emphasizing customer responsibility for proper use.
Contact Information
Contact details for Hamamatsu offices worldwide are provided for support and inquiries.
See more

Catalog excerpts

Infrared Detectors-1

Selection guide - March 2013 INFRARED DETECTORS Covering a broad spectral range in the infrared region INFRARED DETECTORS HAMAMATSU PHOTONICS K.K.

 Open the catalog to page 1
Infrared Detectors-2

Infrared detectors Infrared detectors are widely used in diverse field including measurement, analysis, indust r y, c o m m u n i c a t i o n , a g r i c u l tu r e , m e d i c i n e , physical and chemical science, astronomy and s p a c e . Ba s e d o n l o n g ex p e r i e n c e i nvo l v i n g photonic technology, HAMAMATSU provides a wide variety of infrared detectors in order to meet a large range of application needs. In addition to the st andard devices listed in this catalog, custom devices are also available on request. Please feel free to contact the nearest sales office in your area....

 Open the catalog to page 2
Infrared Detectors-3

InAs/InAsSb/InSb photovoltaic detectors, InSb photoconductive detectors MCT (HgCdTe) photoconductive/ photovoltaic detectors Thermopile detectors (Si thermal detectors) Photon drag detector Two-color detectors Accessories for infrared detectors Infrared detectors

 Open the catalog to page 3
Infrared Detectors-4

Infrared detectors HAMAMATSU infrared detectors Spectral response range (μm) Product name • Short wavelength enhanced type • Can detect light from 0.5 μm • Standard type • High-speed response, high sensitivity, low dark current • Available various types of photosensitive areas, arrays and packages • Types for spectrophotometry and WDM monitor, and high-speed type available Spectral response range (μm) Product name • For NIR spectroscopy • Available TE-cooled type • For optical measurement in the band of water content absorption (1.9 μm) • Available TE-cooled type • For optical measurement around...

 Open the catalog to page 4
Infrared Detectors-5

Spectral response of HAMAMATSU infrared detectors (typical example) 1014 Photovoltaic detectors Photoconductive detectors Si thermal detectors 1013 Short wavelength enhanced type InGaAs (25 °C) Long wavelength type InGaAs (-196 °C) Long wavelength type InGaAs (25 °C) 109 Thermopile detecter When using infrared detectors, the following points should be taken into consideration for making a device selection. Law of black body radiation (Planck's law) 104 As can be seen from the figure above, HAMAMATSU provides a variety of infrared detectors with different spectral response characteristics. It...

 Open the catalog to page 5
Infrared Detectors-6

InGaAs PIN photodiodes Short wavelength enhanced type (Typ. Ta=25 °C, unless otherwise noted) Spectral response range λ (μm) Peak sensitivity wavelength λp (μm) Option (sold separately) Standard type Metal package Various photosensitive area sizes are available. Type no. G8605-25 * Low PDL (polarization dependent loss) type 1 Infrared detectors Option (sold separately) Peak sensitivity wavelength λp (μm) (Typ. Ta=25 °C, unless otherwise noted) Spectral response range λ (μm)

 Open the catalog to page 6
Infrared Detectors-7

InGaAs PIN photodiodes Ceramic package Photosensitive area Spectral response range λ (μm) Peak sensitivity wavelength λp (μm) 1000 Surface mount type ceramic Surface mount type These InGaAs PIN photodiodes are assembled on a small ceramic base originally developed for laser diode monitoring. The G8941 series InGaAs photodiodes use a front-illuminated sensor chip, while the G9230-01 uses a back-illuminated sensor chip mounted on a base without wire bonding to allow an optical fiber to be set in close proximity. Photosensitive area Spectral response Peak sensitivity Cutoff frequency wavelength...

 Open the catalog to page 7
Infrared Detectors-8

Long wavelength type Peak sensitivity wavelength: 1.75 μm These are suitable for optical measurement around 1.7 μm. Type no. Spectral response range λ (μm) (Typ. Ta=25 °C, unless otherwise noted) Peak sensitivity wavelength λp (μm) Option (sold separately) Peak sensitivity wavelength: 1.95 μm These are suitable for optical measurement in the 1.9 μm band such as water absorption. Type no. Spectral response range λ (μm) Peak sensitivity wavelength λp (μm) Option (sold separately) (Typ. Ta=25 °C, unless otherwise noted) Infrared detectors

 Open the catalog to page 8
Infrared Detectors-9

InGaAs PIN photodiodes Peak sensitivity wavelength: 2.3 μm These are suitable for use in NIR (near infrared) spectroscopy. Type no. Spectral response range λ (μm) (Typ. Ta=25 °C, unless otherwise noted) Peak sensitivity wavelength λp (μm) Option (sold separately) Spectral response G12182 series Infrared detectors

 Open the catalog to page 9
Infrared Detectors-10

Infrared detector modules with preamp These modules consist of an InGaAs PIN photodiode assembled with matched preamplifier, and operate by connecting a DC power supply. Photosensitive area Peak sensitivity wavelength λp Measurement condition Element temperature (°C) EN 61326-1 Class B Note: Supplied with a power supply cable Spectral response Infrared detectors

 Open the catalog to page 10
Infrared Detectors-11

InGaAs PIN photodiodes Image sensors, photodiode arrays InGaAs linear image sensors for spectrophotometry One-stage TE-cooled types can be cooled down to -10 °C and cover a spectral range from 0.9 to 1.67 μm. Type no. Applicable driver circuit (sold separately) Defective pixels Photosensitive area Spectral response range λ (μm) Pixel pitch Output can be obtained from all pixels since there are no defective pixels. Suitable for precision measurement. Type no. Defective pixels Applicable driver circuit (sold separately) Photosensitive area Spectral response range λ (μm) Pixel pitch Two-stage TE-cooled...

 Open the catalog to page 11
Infrared Detectors-12

High-speed type InGaAs linear image sensors These are high-speed linear image sensors suitable for industrial and measurement equipment. Type no. Photosensitive area Defective pixels Applicable driver circuit (sold separately) Spectral response range λ (μm) Pixel pitch These are 1024 pixels, high-speed NIR linear image sensors designed for applications such as foreigh object screening and medical diagnostic equipment where a multichannel high-speed line rate is required. Type no. Pixel pitch Spectral response range λ (μm) Defective pixels Applicable driver circuit (sold separately) These linear...

 Open the catalog to page 12

All HAMAMATSU catalogs and technical brochures

  1. SPAD MODULES

    5  Pages

  2. LIGHTNINGCURE

    29  Pages

  3. C13410 series

    4  Pages

  4. C13410-06A

    4  Pages

  5. PMA-12

    8  Pages

  6. L12542

    4  Pages

  7. FLAT EXCIMER

    16  Pages

  8. L15208-01

    3  Pages

  9. L15856-01

    3  Pages

  10. L14001-01

    2  Pages

  11. L11854-336-05

    2  Pages

  12. L14351-02

    4  Pages

  13. GC-113A

    2  Pages

  14. DIUTHAME

    12  Pages

  15. J12853

    2  Pages

  16. J12432-01

    2  Pages

  17. J10919 SERIES

    2  Pages

  18. C15780-401

    4  Pages

  19. H15460-40

    4  Pages

  20. R14755U-100

    2  Pages

  21. C13398 series

    5  Pages

  22. LIGHT SOURCES

    23  Pages

  23. PHOTOTUBES

    8  Pages

  24. PSD

    8  Pages

  25. Photo IC

    8  Pages

  26. Image Sensors

    48  Pages

  27. Si Photodiodes

    48  Pages

  28. Si APD

    16  Pages

  29. FLOW CELLS

    4  Pages

  30. Si photodiodes

    41  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.