Data sheet positioning system PSW 30x-8
3Pages

{{requestButtons}}

Catalog excerpts

Data sheet positioning system PSW 30x-8 - 1

Data interfaces hollow shaft ø 8H9 /  20 depth 6 torque support CANopen, PROFIBUS DP DeviceNet, Modbus RTU, Sercos, , EtherCAT, PROFINET, EtherNet / IP POWERLINK, IO-Link , Duty cycle Supply voltage Vibration resistance Output shaft 8 mm solid shaft or 8 mm hollow shaft with adjustable collar Maximum axial force Storage temperature Protection class IP 68 at standstill 1), IP 66 during rotation (tested with water) 1) welded V2A housing, output shaft sealed with quad-ring The order key and accessories can be found on p. 18 / 19. stainless steel viewing window and access to address switch and status display Ambient temperature Maximum radial force in accordance with IEC / DIN EN 60068-2-6 Dimensions in mm. For details of the connections please see also p. 55 and the instruction manual. Data sheet PSW 30x-8 – Date: 08/ 2021 – Subject to technical changes without notice in accordance with IEC / DIN EN 60068-2-27 not subject to mechanical limits Shock resistance Positioning range absolute measurement of position taken directly at the output shaft PSW 30x-8-V (with solid shaft) Positioning accuracy viewing window and access to address switch and status display between control and motor and bus Power consumption (control unit) 24 V DC ± 10 % galvanically separated Nominal current

Open the catalog to page 1
Data sheet positioning system PSW 30x-8 - 2

ORDER KEY PSE / PSS / PSW 3 SERIES  A CA: CANopen Positioning System Efficient (see p.22 - 28)  Positioning System Stainless (see p.29 - 33) Positioning System Washable (see p.34 - 38) not for PSE 31x always via an extra connector plug, not for IO-Link or PSW 5) not for PSE 34xx 3) 4) 0: CE N: NRTL + CE S: STO + CE without test pulses 7) 0: without M: with 6) Z: Plug-in, Y-coded, with jog keys 3)  5) T: TO + CE with S test pulses 7) Y: TO + NRTL S without test pulses 7) Z: TO + NRTL S with test pulses 7) 6) only 14 mm output shafts only for IP 65, not for PSE 34xx, only for EtherCAT,...

Open the catalog to page 2
Data sheet positioning system PSW 30x-8 - 3

ACCESSORIES PSE / PSS / PSW 3 SERIES The connectors shown here can be used for all 3 types of device (PSE / PSS / PSW). This ensures that the PSE (IP 54) and PSS (IP 65) comply with the IP protection classes. We will also be pleased to help you find a suitable mating connector for the PSW (IP 68) if necessary – just ask us! Power supply + databus connector  (2x) (for option 0)  1) Power supply + databus (2x) + jog key connector (for option T, not for PSW) 1) 2) Cable and connectors for 1-connector solution 3) (for option Y or IO-Link) 1) CANopen 4) PROFIBUS DP Modbus RTU   5 m: Order no....

Open the catalog to page 3