Data sheet positioning system PSS 3210/3218-14 - 1

Self-holding torque Nominal rated speed Nominal torque hollow shaft ø 14H7 / 20 depth Data interfaces CANopen, PROFIBUS DP DeviceNet, Modbus RTU, Sercos, , EtherCAT, PROFINET, EtherNet / IP POWERLINK, IO-Link , Duty cycle Positioning range Shock resistance Vibration resistance Output shaft as for PSE, but with stainless steel housing Protection class Data sheet PSS 3210 / 3218-14 – Date: 08/ 2021 – Subject to technical changes without notice Storage temperature Dimensions in mm. For details of the connections please see also p. 55 and the instruction manual. CE, optional: NRTL, opt: STO with / without test pulses 3) in accordance with IEC / DIN EN 60068-2-6 optional (holding torque = nominal torque) in accordance with IEC / DIN EN 60068-2-27 over a rotating manual adjustment shaft SW 6 / 8 depth hex 14 mm hollow shaft with adjustable collar Ambient temperature Maximum radial force absolute measurement of position taken directly at the output shaft Maximum axial force Snap-on brake Positioning accuracy viewing window and access to address switch and status display 26 Power consumption (control unit) torque support 24 V DC ± 10 % galvanically separated between control and motor and bus Nominal current Supply voltage not subject to mechanical limits welded V2A housing, ball bearings at the output shaft with sealing disc   STO: only for IP 65, only for EtherCAT, PROFINET, Ether

Open the catalog to page 1
Data sheet positioning system PSS 3210/3218-14 - 2

ORDER KEY PSE / PSS / PSW 3 SERIES  A CA: CANopen Positioning System Efficient (see p.22 - 28)  Positioning System Stainless (see p.29 - 33) Positioning System Washable (see p.34 - 38) not for PSE 31x always via an extra connector plug, not for IO-Link or PSW 5) not for PSE 34xx 3) 4) 0: CE N: NRTL + CE S: STO + CE without test pulses 7) 0: without M: with 6) Z: Plug-in, Y-coded, with jog keys 3)  5) T: TO + CE with S test pulses 7) Y: TO + NRTL S without test pulses 7) Z: TO + NRTL S with test pulses 7) 6) only 14 mm output shafts only for IP 65, not for PSE 34xx, only for EtherCAT,...

Open the catalog to page 2
Data sheet positioning system PSS 3210/3218-14 - 3

ACCESSORIES PSE / PSS / PSW 3 SERIES The connectors shown here can be used for all 3 types of device (PSE / PSS / PSW). This ensures that the PSE (IP 54) and PSS (IP 65) comply with the IP protection classes. We will also be pleased to help you find a suitable mating connector for the PSW (IP 68) if necessary – just ask us! Power supply + databus connector  (2x) (for option 0)  1) Power supply + databus (2x) + jog key connector (for option T, not for PSW) 1) 2) Cable and connectors for 1-connector solution 3) (for option Y or IO-Link) 1) CANopen 4) PROFIBUS DP Modbus RTU   5 m: Order no....

Open the catalog to page 3