Data sheet positioning system PSE 3310/3325-14
3Pages

{{requestButtons}}

Catalog excerpts

Data sheet positioning system PSE 3310/3325-14 - 1

Nominal rated speed Data interfaces CANopen, PROFIBUS DP DeviceNet, Modbus RTU, Sercos, , EtherCAT, PROFINET, EtherNet / IP POWERLINK, IO-Link , Duty cycle sealing plate 2 mm thick 5 Supply voltage 24 V DC ± 10 % galvanically separated between control and motor and bus hollow shaft ø14H7 / 20 depth with clamp and feather key DIN 6885-A5 x 5 x 12 Positioning range Shock resistance Vibration resistance Output shaft 14 mm hollow shaft with clamp and feather key Snap-on brake optional (holding torque = nominal torque) Maximum axial force Maximum radial force Ambient temperature Storage temperature Protection class Power consumption (control unit) Positioning accuracy CE, optional: NRTL, opt: STO with / without test pulses 1) absolute measurement of position taken directly at the output shaft Data sheet PSE 3310 / 3325-14 – Date: 08/ 2021 – Subject to technical changes without notice Self-holding torque removeable sight glass for LED status / address switches Nominal torque in accordance with IEC / DIN EN 60068-2-27 in accordance with IEC / DIN EN 60068-2-6 removeable sight glass over a rotating manual adjustment shaft SW3 depth hex Dimensions in mm. For details of the connections please see also p. 55 and the instruction manual. not subject to mechanical limits S TO: only for IP 65, only for EtherCAT, PRO

Open the catalog to page 1
Data sheet positioning system PSE 3310/3325-14 - 2

ORDER KEY PSE / PSS / PSW 3 SERIES  A CA: CANopen Positioning System Efficient (see p.22 - 28)  Positioning System Stainless (see p.29 - 33) Positioning System Washable (see p.34 - 38) not for PSE 31x always via an extra connector plug, not for IO-Link or PSW 5) not for PSE 34xx 3) 4) 0: CE N: NRTL + CE S: STO + CE without test pulses 7) 0: without M: with 6) Z: Plug-in, Y-coded, with jog keys 3)  5) T: TO + CE with S test pulses 7) Y: TO + NRTL S without test pulses 7) Z: TO + NRTL S with test pulses 7) 6) only 14 mm output shafts only for IP 65, not for PSE 34xx, only for EtherCAT,...

Open the catalog to page 2
Data sheet positioning system PSE 3310/3325-14 - 3

ACCESSORIES PSE / PSS / PSW 3 SERIES The connectors shown here can be used for all 3 types of device (PSE / PSS / PSW). This ensures that the PSE (IP 54) and PSS (IP 65) comply with the IP protection classes. We will also be pleased to help you find a suitable mating connector for the PSW (IP 68) if necessary – just ask us! Power supply + databus connector  (2x) (for option 0)  1) Power supply + databus (2x) + jog key connector (for option T, not for PSW) 1) 2) Cable and connectors for 1-connector solution 3) (for option Y or IO-Link) 1) CANopen 4) PROFIBUS DP Modbus RTU   5 m: Order no....

Open the catalog to page 3

All Halstrup-walcher GmbH catalogs and technical brochures