Data sheet mobile calibration device KAL 100 / 200
2Pages

{{requestButtons}}

Catalog excerpts

Data sheet mobile calibration device KAL 100 / 200 - 1

KAL 100/200 Series 3 Description At halstrup-walcher you can find the KAL100/200 Series 3 pressure calibration which offer outstanding value for money and can be used either for stationary (e.g. in a customer's own laboratory) or mobile applications. These devices combine integrated pressure generation for setting the calibration point and high-precision pressure measurement. Properties / Benefits x igh precision measurement and calibration device H x igh flexible while it runs on mains supply or battery H x utomatic zero-point correction provides high A zero-point stability x nternal pump quickly and accurately generates negative or I positive differential pressures of -80 kPa up to 100 kPa x nit conversion (e.g. mmHg, mmH2O, psi, etc.) U x nsuring the calibration interval by displaying the last E calibration x witching power supply for automatic adjustment of the S voltage supply between 85 VAC and 264 VAC for the worldwide use The KAL 100/200 enables you to calibrate pressure gauges yourself. However, if you wish to use the calibration device as a reference, it should be calibrated by DKD-directive 6-1. The KAL is suitable for calibrating: x ifferential pressure gauges in cleanrooms (pharma, semid conductors etc.) x blood pressure monitoring equipment in hospitals etc. Control accuracy of the Pressure generation Overload capacity Temperature coefficient zero point ± 0 % (cyclical zero-point correction) Calibration temperature Measurement input Alphanumeric display with 2 x 20 characters, backlighting Rated temperature range Storage temperature Pressure ports x differential pressures in air-conditioning systems target test value function tubing pressure connections measurement menu selection Data sheet KAL 100/200 Series 3 – Date: 12/ 2022 – Subject to technical changes wit

Open the catalog to page 1
Data sheet mobile calibration device KAL 100 / 200 - 2

Transport case KAL 100 / 200 Order no. 9220.0002 Pressure generation Applications Measurement ranges Temperature coefficient span (10 .. 40 ° C) Carrying bag KAL 100 / 200 supplied as standard Recalibration service Order no. ISO factory calibration certificate 9601.0136 Calibration certificate with 9601.0288 DKD-directive 6-1 Your Product request Please use the boxes below to select the respective specifications for your product. Model USB-Interface and analog measurement input for test object Battery life Measurement ranges Data sheet KAL 100/200 Series 3 – Date: 12 / 2022 – Subject to...

Open the catalog to page 2

All Halstrup-walcher GmbH catalogs and technical brochures