1. Catalogs
  2. halstrup-walcher GmbH
  3. Data sheet differential pressure transmitter REG 21

Data sheet differential pressure transmitter REG 21

Data sheet differential pressure transmitter REG 21

Data sheet differential pressure transmitter REG 21

Product catalog summary
Specifications:
The document outlines the specifications for a differential pressure measurement and regulation device. Key specifications include a margin of error of ±0.5% or ±1% of the maximum value, various power supply options (24 V DC, 24 V AC, 115 V AC, 230 V AC), and output options (0-10 V, ±5 V, 0-20 mA, 4-20 mA). The measurement range is customizable, with standard ranges provided, and the device supports a maximum system pressure of 10 kPa for certain ranges.

Procedures:
The device is used for measuring differential pressure in applications such as ventilation and air-conditioning technology. It features automatic zero-point correction and high overload protection. The device can function as a 2-point or 3-point regulator for controlling final elements like pumps or fans.

Standards and Certifications:
The device complies with CE standards and offers optional DAkkS and ISO calibration certificates. It is designed for use with non-aggressive gases and operates within a temperature range of 10 to 60 °C.

Recommendations:
The document recommends using the device for stationary measurement of differential pressure and highlights its suitability for clean-room monitoring and other critical applications. It also suggests using the free user software for parameter setting and data recording.

Accessories:
Various accessories are available, including silicone and Norprene tubing, Y-pieces for tubing, and customer-specific pressure ports.

Key Features:
The device offers accurate pressure measurement with automatic zero-point correction, high overload protection, and adjustable time constants. It is housed in a control panel and supports user-friendly parameter settings via software.
See more

Catalog excerpts

Data sheet differential pressure transmitter REG 21-1

(0.3 Pa margin of error for the reference) Temperature coefficient span Temperature coefficient zero point ± 0 % (cyclical zero-point correction) Overload capacity 200 x for measurement ranges < 2.5 kPa 600 kPa for measurement ranges ≥ 2.5 kPa 10 kPa for measurement ranges ≤ 10 kPa max. nominal pressure of sensor others available upon request for measurement ranges above 10 kPa Sensor response time Time constants Operating temperature Storage temperature Power consumption Pressure ports Protection class xx Pressure measurement and regulation in a device xx ccurate measurement of differential pressure A with automatic zero-point correction and high overload protection xx witching outputs can be used as 2-point regulator S (pressure switch), for activating / deactivating a final control element (e.g. pump), with relay hysteresis xx witching outputs can be used as a 3-point regulaS tor (e.g. ON 1 - OFF - ON 2) for activating / deactivating two final control elements, (e.g. air intake / outflow fans), with relay hysteresis xx Asymmetry also possible, e.g. - 10 .. 40 mbar Measurement range Measurement range xx Housing: control panel housing (installed) Margin of error Power supply 48 select values or parameters call up parameter settings and display functions 115 V AC, + 6 % / -15 % (50 / 60 Hz) start and close settings 24 V DC, + 20 % / -15 % 24 V AC, + 6 % / -15 % (50 / 60 Hz) (with galvanic separation) Contact points 2 relays with floating changeover contacts 230 V AC (50 / 60 Hz), 6 A 2 transistors with open collector UCE ≤ 50 V; IC ≤ 200 mA, floating Data sheet REG 21 – Date: 08 / 2017 – Subject to technical chan

 Open the catalog to page 1
Data sheet differential pressure transmitter REG 21-2

Measurement of differential pressure Measurement of differential pressure is useful in a broad range of applications. It is used in ventilation and air-conditioning technology but also in many areas of air handling process technology. The next pages show a number of these. You can find more information about our pressure sensor technology on p. 6. halstrup-walcher offers a wide range of products for stationary measurement of differential pressure: Product Process monitoring for cleanrooms (Pa, ° C, % rH), with stainless steel front Process monitoring panel aluminium, anodised (optional: with...

 Open the catalog to page 2

All Halstrup-walcher GmbH catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.