Catalog excerpts

Data sheet differential pressure transmitter PS 17-1

PS 17 Measurement ranges (also ±) Temperature coefficient span Temperature coefficient zero point Max. system pressure / Overload capacity ± 25 kPa: measurement ranges ≤ 250 Pa ± 50 kPa: measurement ranges > 250 Pa dry air, all non-aggressive and non-flammable gases Step response time (T63) (Time constant) Rated temperature range Storage temperature Calibration temperature Power consumption Pressure ports Protection class others available upon request Picture: Version with display Features x ompact differential pressure transmitter for basic C applications in cleanrooms, machines, HVAC or filter monitoring for measurement ranges ≤ 250 Pa plus ± 1 Pa M easurement accuracy for the reference 0.3 Pa, for measuring ranges ≤ ±1.5 kPa x obust ABS housing with IP 67 for top-hat rail R or wall mounting x ± and asymmetric measurement ranges 1 relay (exchange contacts) 4) max. 230 V AC, 6 A x Either with one fixed measurement range or toggling between 4 different measurement ranges x Pressure units Pa, kPa (inear output signal) l x quare-root output signal in % of max. possible value S x Configurable via DIP switches with galvanic separation Optional display Measurement range x Plug for easy commissioning Display none 24 V AC / DC 50 / 60 Hz ± 10 % reverse pole protection x Fine adjustment via internal pushbutton Data sheet PS 17 – Date: 09 / 2022 – Subject to technical changes without notice c an be configured using DIP switches, conversion into square root signal adjustable (in % of max. possible value) Power supply x ero point correction and via internal pushbutton Z or digital input Relay parameters can be pre-set on request F actory preset, configurable via button Electrical connection spring-type terminal, 2 x M 16 cable glands spring-type terminal, M 20 cable gland 7) not for changeover contacts / relay (D) Factory calibration Calibration according to DKD-R 6-1

 Open the catalog to page 1
Data sheet differential pressure transmitter PS 17-2

MEASUREMENT OF DIFFERENTIAL PRESSURE Measurement of differential pressure is useful in a broad range of applications. It is used in ventilation and air-conditioning technology but also in many areas of air handling process technology. halstrup-walcher offers a wide range of products for stationary measurement of differential pressure: Product High precision, freely scalable pressure transmitter for critical applications Measuring transmitter with very small dimensions – ideal for the control cabinet High precision, freely scalable pressure transmitter for natural gas Housing installation For...

 Open the catalog to page 2

All Halstrup-walcher GmbH catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.