Catalog excerpts

P 34 Measurement ranges (also ± measurement ranges) others available upon request freely scalable from 10 .. 100 % within a measurement range or ± 0.5 % FS Temperature coefficient span 400 kPa measurement ranges ≥ 2.5 kPa 200 x measurement ranges < 2.5 kPa Step response time (T63) (Time constant) Rated temperature range Storage temperature Power consumption pluggable screw terminals Power supply USB 2.0 Full-Speed Slave (Mini USB) Protection class x ifferential pressure transmitter D with very small dimensions – ideal for control cabinet installation ± 0 % (cyclical zero-point correction) Max. system pressure / Overload capacity Temperature coefficient zero point Measurement accuracy for the reference 0.3 Pa, for measuring ranges ≤ ±1.5 kPa x ero-point correction prevents Z zero-point drift Measured data for P- / -compensated volume flow (optional) T x uilt-in valve provides a high level of B overpressure protection Measured range absolute pressure x olume flow can be configured via k-factor, dPmax / Vmax or 20 V individual values Accuracy absolute pressure Temperature input x SB interface: via PC-software scaling, characteristic line form U and many other parameters can be set Optional x - / -compensated volume flow (temperature analogue input and P T internal stat. pressure sensor) Measurement range x ith relay or push-on elbow connector w Push-on elbow connector 4 mm Option: relay Push-on elbow connector 3 mm Measurement range Tubing connectors o utput signals can be configured freely P- / T- compensated volume flow x elivery possible already completely integrated into the D control cabinet (on request) (linear / root extracted) x ree software available at www.halstrup-walcher.de/en/software F Push-on elbow connector 6 mm Calibration certificate Factory calibration Calibration according to DKD-R 6-1 Contact points Attachment for top-hat rail Analogue outputs Supply 24 V AC / DC + option temperature input at P- / -compensated volume flow T Option: push-on elbow connector for 3, 4 or 6 mm tubing Measurement accuracy Data sheet P 34 – Date: 09 / 2022 – Subject to technical changes without notice Temperature range freely scalable Can be pre-set on request: Time constant, relay parameter, analogue output rootextr
Open the catalog to page 1
MEASUREMENT OF DIFFERENTIAL PRESSURE Measurement of differential pressure is useful in a broad range of applications. It is used in ventilation and air-conditioning technology but also in many areas of air handling process technology. halstrup-walcher offers a wide range of products for stationary measurement of differential pressure: Product High precision, freely scalable pressure transmitter for critical applications Measuring transmitter with very small dimensions – ideal for the control cabinet High precision, freely scalable pressure transmitter for natural gas Housing installation...
Open the catalog to page 2All Halstrup-walcher GmbH catalogs and technical brochures
-
HIPERDRIVE HDA 70
2 Pages
-
Data sheet HDA 70
2 Pages
-
Flow rate calibrations
4 Pages
Archived catalogs
-
Drive technology catalog
36 Pages