FR-MPFM

FR-MPFM

FR-MPFM

Product catalog summary
Introduction
The Haimo full range multiphase flow meter integrates a gas/liquid two-phase flow meter with a three-phase water cut meter. It measures gas and liquid flow rates using a venturi and a gamma meter, while the Water Liquid Ratio (WLR) is determined by a dual gamma meter.

Design Philosophy and Principle of Operation
The meter's design includes a flow conditioner to improve WLR accuracy by mitigating slugging and reducing high Gas Volume Fraction (GVF). This ensures a water cut measurement error within ±2% across the meter's operating range.

Measurement Principle
The venturi flow meter measures the total flow rate, while gamma ray technology assesses phase fractions, GVF, and WLR. An inline sampler reduces gas fraction, enhancing WLR accuracy even at high GVF. A multivariable transmitter (MVT) records pressure, temperature, and differential pressure, with data processed by a high-frequency transmitter and a Data Acquisition Unit (DAU) converting measurements to standard conditions.

Performance
Meter Specifications:
Meter sizes range from 1.5 to 6 inches, with WLR and GVF both spanning 0-100%. Materials include CS, SS, DSS, Inconel, and Alloy, with electrical certification EEx dll B T4/T6 and ingress protection IP 65/66.
Measurement Uncertainty:
For GVF ranges 0-95%, liquid flow uncertainty is 5.0%, gas flow 7.0% (5.0% for P≥20Bar), and water cut 2.0%. For 95-100% hydrocarbon flow, uncertainty is 5-10% (3.0% for P≥20Bar), gas flow 7.0% (2.0% for P≥20Bar), and water cut 2.5%.

Features
The meter excels in water cut measurement, crucial for net oil accuracy. It operates independently of flow regime, with a wide range and low pressure drop. The design is non-intrusive, compact, robust, and cost-effective, suitable for remote locations. High-frequency data acquisition provides real-time well data at line and standard conditions.
See more

Catalog excerpts

FR-MPFM-1

Full Range Multiphase Flow Meter The Haimo full range multiphase flow meter is a combination of a gas / liquid two phase flow meter and a three phase water cut meter. Introduction Design Philosophy and Principle of Operation The Haimo full range multiphase flow meter is a combination of a gas / liquid two phase flow meter and a three phase water cut meter. Measurement of the gas and liquid flow rates is carried out in the gas / liquid two phase meter that consists of a venturi and a single gamma meter. The Water Liquid Ratio (WLR) is measured with the dual gamma meter which is located downstream of the flow conditioner. The phase fractions are derived from these two independent measurements and net oil flow rate is finally calculated using the gross liquid flow rate and water cut measurement. In deteriorates with slugging as well as very high Gas Volume Fraction (GVF), therefore in order to measure WLR accurately Haimo has introduced a flow conditioner upstream of the dual energy gamma water cut meter to condition the multiphase flow by mitigating slugs and reducing the higher GVF level. This helps achieve the water cut measurement error within ± 2% absolute for the full range of stated GVF in the meter’s operating envelope.

 Open the catalog to page 1
FR-MPFM-2

Measurement principle Total flow rate of the multiphase stream is measured by the venturi flow meter. Gamma ray technology is used to measure phase fractions, GVF and WLR respectively. A patented inline sampler helps to decrease gas fraction in the multiphase flow and enables accurate WLR measurement even at extremely high GVF. The multivariable transmitter (MVT) measures pressure, temperature and differential pressure. The pulses from the gamma meters are processed by a new design of high-frequency transmitter. A Data Acquisition Unit (DAU) performs all calculations and converts flow measurements...

 Open the catalog to page 2
FR-MPFM-3

Measurements Uncertainty (Confidence Level=95%): GVF Range Liquid flow (rel) Gas flow (rel) Water cut (abs) Hydrocarbon flow (rel) Gas flow (rel) Water cut (abs) Best in class for water cut measurement – a key factor in resulting net oil accuracy Flow regime independent Wide operating range with low pressure drop Non–intrusive and in–line measurement techniques Field oriented design, small footprint and cost effective mobilization Compact, robust and easy to install meter –ideal for remote locations High frequency data acquisition, provides real time well data at line and standard conditions...