海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Temperature and Humidity Test Chamber (100L, -40℃~150℃) Operation Manual Model: HD-E702-100-4 Power: Single-p

Open the catalog to page 1
Operation Manuel of Temperature and Humidity Test Chamber - 2

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual PREFACE Thanks for you choose our company products, we not only provide high quality, but also reliable after-sales service. In order to ensure the safe of the user and the integrity of the machine, please read the operate instruction carefully before use the instrument, pay more attention to the using notes. This operating manual will introduce the design principles, design criteria, structure, operating norms, calibration, maintenance, some failure case and solutions, electrical diagram so on. If this operating manual in...

Open the catalog to page 2
Operation Manuel of Temperature and Humidity Test Chamber - 3

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Directory Introduction -------------------------------------------------------------------------------------------- 4 Equipment Instruction ---------------------------------------------------------------------------- 5-6 Equipment Installation------------------------------------------------------------------------------- 7 Operate Practices --------------------------------------------------------------------------------- 8-10 Fault resolution---------------------------------------------------------------------------------------...

Open the catalog to page 3
Operation Manuel of Temperature and Humidity Test Chamber - 4

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Introduction 1, Usage: Temperature Humidity Chamber simulates a variety of temperature and humidity environmental for testing electronics, automobiles, rubber, plastic rubber, metal and other products. To meet the international test standard and a variety of harsh environment parameters, such as reliability and stable performance. It will provide you a basis of predict and improve product quality and reliability. 2, Principle The machine adopts high stability of PT-100 platinum resistance temperature body, LCD in English and...

Open the catalog to page 4
Operation Manuel of Temperature and Humidity Test Chamber - 5

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Equipment Instruction Product image (picture 1) 1. Operation panel 2. Chamber door handle 3. Observation Window 4

Open the catalog to page 5
Operation Manuel of Temperature and Humidity Test Chamber - 6

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Control panel (picture 2) 1, Controller 2, Alarm 3, Power 4, Over-temp. Protector 5, RS-232 6, Door light 7, Water Indicate Instruction: 1, Controller: the machine adopted PLC control system 2, Alarm indicator: send alarm indication automatically when the machine running abnormal; 3, Power: the machine power switch; 4, Over-temperature protector: prevent the machine from heating when reach the set temperature; 5, RS-232: communication port to connect pc; 6, Door lights: turn on the switch can observe the specimen in test...

Open the catalog to page 6
Operation Manuel of Temperature and Humidity Test Chamber - 7

User Manual HAIDA INTERNATIONAL EQUIPMENT CO., LTD. 1, Power condition: connect the power source according to indication on the nameplate. 2, Operating environment conditions: Room temperature, Humidity <80%RH 3, Installation requirements: (1) The machine should be installed in level ground, and consider the cooling rate, easy to check and maintenance; (2) The distance between machine and wall or other machine should be at least 60 cm; (3) The machine should be away from heat and flammable/ explosive substances; (4) The machine can not to be under direct sunlight, and maintain indoor air...

Open the catalog to page 7
Operation Manuel of Temperature and Humidity Test Chamber - 8

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Operate practices Preparation 1, Confirm the power and connect ground wire -the power wire should be in accordance with installation and connect the ground wire. 2, Note: please remove the gauze when only do the temperature test, and it should be changed after running up to 85℃. 3, Confirm the water supply: -water storage? -clean or not? (clean once a month, replace the gauze each three month) 4, Confirm the special gauze: -The position is ok? (humidity sensors are placed in front of the location?) -Wetting? (if water level is...

Open the catalog to page 8
Operation Manuel of Temperature and Humidity Test Chamber - 9

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Test operation 1, After connect the power, open power switch,power light on, controller enter fix value interface 2, Open the door,put the specimen on the shelf;then closed the door; Note: the sample volume should not exceed the capacity of 2/3 test area; 3, According to “controller operation manual”, set the test operation, then following the operate model enter the test situation; 4, If you want to observe the change in chamber, you can open the door light; the controller will display the temperature and humidity change in...

Open the catalog to page 9
Operation Manuel of Temperature and Humidity Test Chamber - 10

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual In operating, unless absolutely necessary, do not open the door, or it may result in the following adverse consequences: - High temperature moisture is dangerous when out of the chamber. - Inside the box door is still held high-temperature may cause damage. - High temperature air could trigger a fire alarm malfunction. 8, Please note that the machine must be securely grounded truly in order to avoid electrostatic induction. 9, Avoid close within three minutes then turn the frozen unit. 10, If placed the hot specimen inside the...

Open the catalog to page 10
Operation Manuel of Temperature and Humidity Test Chamber - 11

User Manual HAIDA INTERNATIONAL EQUIPMENT CO., LTD.

Open the catalog to page 11
Operation Manuel of Temperature and Humidity Test Chamber - 12

海達國際儀器有限公司 HAIDA INTERNATIONAL EQUIPMENT CO., LTD. User Manual Alarm Trouble Shooting Code DI1 Machine part image Inside chamber over temperature Check the setting value of Temp Protector, and if the circulation fan is get stuck or stop working. Check if the condensation fan is stop working? Condenser is dirty? Compressor is abnormal? Press the BLUE RESET button. Check if the condensation fan is stop working? Condenser is dirty? Compressor is abnormal? Press the BLUE RESET button. Check if the circulation fan is get Air channel over temperature stuck or stop working? Controller temperature...

Open the catalog to page 12
Operation Manuel of Temperature and Humidity Test Chamber - 13

User Manual HAIDA INTERNATIONAL EQUIPMENT CO., LTD. Wetbulb gauze must be installed inside wet bulb gauze sink, otherwise wet bulb gauze will not absorb water abundantly leading to unstable humidity control. WetBulbGauze Sink / ' * 1 'in-^4—1~ *G auze cannot be installedhere Fig. 5,10 Top View of Wet Bulb Gauze Sink Wet bulb gauze must be installed when conducting humidity test. Please check whether the gauze is moist or not when humidity test starts. If it has lost water absorbability, please replace it. Note: Bacteria will be reproduced on the wet bulb gauze during humidity...

Open the catalog to page 13

All HAIDA EQUIPMENT CO. catalogs and technical brochures

  1. IP ratings

    2 Pages

  2. Safety shoes

    2 Pages

  3. Drop Tester

    3 Pages

  4. WHAT IS ISTA

    2 Pages

  5. Battery Test

    6 Pages

  6. Tape Tester

    1 Pages

  7. History

    1 Pages

  8. Eid al Adha

    1 Pages

  9. ISTA MEMBER

    1 Pages

  10. Catalog

    1 Pages

  11. HD-B615

    1 Pages

  12. HD-E702

    1 Pages

  13. HD-703

    1 Pages

  14. HD-E704

    1 Pages

  15. tensile tester

    13 Pages

  16. drying oven

    1 Pages

Archived catalogs