Preamplifier PAM2 - 1

Product Description Preamplifier PAM2 Special Features □ Combinable with AME, DCM, DCX and DMA □ 100-fold increase of strain gauge signal Scope of Supply - Preamplifier in aluminum enclosure Version - Option 1: 1 channel - Option 2: 2 channel - Option J: Strain gauge supply voltage 5 V Construction: Aluminium enclosure 140 x 140 x 90 mm (L x B x H) Fixing: 4 screws M6 In production plants the distance between force sensor and control cabinet is often higher than the permissible length of cable. For these applications is the preamplifier PAM is especially suitable. The low level of the strain gauge sensor signals will be raised to a 100-fold value and with its low output impedance the noise susceptibility is significantly reduced. The settings for the zero point are made on the downstream amplifier. HAEHNE Elektronische Messgerate GmbH ■ Heinrich-Hertz-Str.29 ■ D-40699 Erkrath Germany ■ Telefon 0211/92591-0 ■ Fax 0211/92591-20 http://www.haehne.de Email: info@haehne.de

Open the catalog to page 1
Preamplifier PAM2 - 2

*2 channel version only Wiring diagram for amplifier AME and DMA Technical Data Technical modifications reserved HAEHNE Elektronische Messgerate GmbH ■ Heinrich-Hertz-Str.29 ■ D-40699 Erkrath Germany ■ Telefon 0211/92591-0 ■ Fax 0211/92591-20 http://www.haehne.de Email: info@haehne.de