Catalog excerpts
Scope of Supply - Amplifier in cast aluminium enclosure with analog display - Standard (Option U): 2 voltage outputs (direct / filtered) Versions - Option C: 1 current output, 4...20 mA 2 voltage outputs (direct / filtered) - Option N: 1 current output, 0.20 mA 2 voltage outputs (direct / filtered) Additional Accessories - Option E: Enlarged excitation supply 160 mA Product Description Measuring Amplifier MV128 Special Features □ Compact design, ideal for retrofitting and test installations □ 1 channel with connectors for 2 parallel strain gauge sensors □ Integrated strain gauge excitation supply and force display (in % FN) □ 24 V DC power supply □ Power supply and signal outputs galvanically isolated Application The measuring amplifiers MV128 are used preferably in cases when the analog measuring signals of sensors must be amplified close to their location on machines and equipment. A 24 V DC power supply is needed only to operate the amplifier. Due to its compact design and its competitive price, the MV128 is an interesting alternative to more complex amplifiers. All components of the multi-stage amplifier MV128, as well as the voltage regulator for the strain gauge excitation voltage are on a PCB measuring 94 * 46 mm. Two zero adjust potentiometer are available for eliminating off sets (e.g. the roll weight). The desired gain can be adjusted with two potentiometer (coarse and fine). Two voltage outputs with different types of filters are available. The current output (option C and N) can be connected to either one of these outputs. The connection of the power supply is short-circuit protected. The outputs are galvanically isolated from the auxiliary power. HAEHNE Elektronische Messgerate GmbH ■ Heinrich-Hertz-Str.29 ■ D-40699 Erkrath Germany ■ Telefon 0211/9 2591-0 ■ Fax 0211/92591-20 http://www.haehne.de Email: info@haehne.de
Open the catalog to page 1MV128 Technical Data Strain gauge excitation supply Voltage V4 : 10 V Current max.: 60 mA Option E: 160 mA Zero adjust compensation voltage (in relation to voltage input): -25 ... 0 ... +25 mV Amplification Adjustment range: 400...3200 V/ V Factory adjustment: 667 V/ V Temperature range 0...60°C Terminal cross-section Standard enclosure protection: Selector switch S1 dampening characteristics current output: Signal output Voltage ( V2 , V3 ): min. load resistance (V2): min. load resistance (V3): Signal rising time (10...90 %): Current (I1 ) Option C: Option N: Max. load resistance:...
Open the catalog to page 2All HAEHNE catalogs and technical brochures
-
Digital Panelmeter PM2
2 Pages
-
Preamplifier PAM2
2 Pages
-
Measurement Amplifier MV127
2 Pages
-
Inline Cable Amplifier CA
2 Pages
-
Strain Gauge Amplifier AME2
2 Pages
-
Handheld Amplifier PAD2
2 Pages
-
Force Measurement Bolts KMB
2 Pages
-
Measuring Roll KAT
2 Pages
-
Force Measuring Sensor BZL
2 Pages
-
Measuring Bearing EBZ
2 Pages
-
Force Measuring Bearing BZA
2 Pages
-
Biaxial Force Sensor BZ-XY
1 Pages
-
Pillow Block Sensor BZH-K00
2 Pages
-
Pillow Block Sensor BZV-A
2 Pages
-
Pillow Block Sensors BZH-A
2 Pages
-
Adjustmentbox J-Box
2 Pages
-
Busbox P2 for Field Mounting
4 Pages
-
Force Measuring Roll MESA
2 Pages
-
Bearing Support LBZR
1 Pages
-
Pillow Block BZV-F
2 Pages
-
Pillow Block Sensors BZHB
2 Pages
-
Pillow Block Sensors BZH
2 Pages
-
Compression Force Load Cells
2 Pages
-
PROFINET Amplifier DA-PN
2 Pages
-
Web Tension Sensor BZH
2 Pages
-
Force Sensor ZAK
2 Pages
-
Web Tensio Sensor BZA
2 Pages
-
Force Sensor BZH-K01+02
2 Pages
-
Force Sensor BZH-K03
2 Pages
-
Force Measuring Bearing BZN
2 Pages
-
Ring force sensor RKS01
4 Pages
-
Ring force sensor RKS02
2 Pages
-
Compression Force Sensor DK2
2 Pages
-
Compression Force Sensor DK3
2 Pages
-
Measuring Roll MEZ
2 Pages
-
Force Measuring Roll MES
2 Pages
-
Measuring roll MUW
2 Pages
-
Force Measurement Bolt KMB-A
2 Pages
-
Measuring Amplifier MV125
2 Pages
-
Force Sensor XYR
2 Pages
-
Amplifier Busbox Profibus
4 Pages
-
Tension Load Cells
2 Pages
-
Measuring Rolls
2 Pages