1. Catalogs
  2. HAEHNE
  3. Adjustmentbox J-Box
cad

Adjustmentbox J-Box

Adjustmentbox J-Box

Adjustmentbox J-Box

Product catalog summary
Overview
The adaption module, known as the J-Box, is designed for use with measuring amplifiers and force measurement sensors that lack internal adaption resistors. It is particularly useful for adapting sensors to higher temperature ranges and potentially explosive atmospheres.
Specifications
  • The J-Box includes resistors necessary for zero adjustment and nominal rating.
  • It is designed for DIN rail mounting in electrical cabinets.
  • Standard enclosure protection is rated at IP 20.
  • Temperature range: 0 to 60°C (32 to 140°F).
Explosion Protection
  • Equipment group II (2) G.
  • Parameters Ci and Li are 0, while Ui and Pi are determined by accessories.
Dimensions
  • DIN-rail enclosure dimensions: 22.5 x 110 x 75 mm (B x L x H).
Scope of Supply
  • Electronic module in standard DIN rail enclosure.
  • Adaption Module J-Box.
Special Features
  • Allows operation of HAEHNE sensors without internal adaption resistors, suitable for potentially explosive atmospheres.
  • Facilitates connection of intrinsically safe circuits in control cabinets.
Wiring and Safety
  • Wiring configurations are available for higher temperature ranges and explosion-proof setups with HAEHNE amplifiers (DMA, MAC, AME).
  • Safety barrier modules and potential equalization cables are used for intrinsic safety in hazardous areas.
Calibration and Compatibility
  • Calibration resistors in the J-Box are specific to the corresponding sensor and must match the sensor's measurement location designation.
  • Example: Sensor 04711-5 must be connected to J-Box 04711-5.
Additional Notes
  • Cables under 5 meters in length within the control cabinet do not require shielding.
See more

Catalog excerpts

Adjustmentbox J-Box-1

Scope of Supply Electronic Modul in standard DIN rail enclosure Special Features • Operation of HAEHNE sensors without internal adaption resistors, e.g. for applications in potentially explosive atmospheres • For connecting intrinsically safe circuits in control cabinets Technical Data Standard enclosure protection: IP 20 Explosion Protection Technical Data Explosion protection equipment group II (2) G - C.; L~ 0 i i - U. And P. are determined by .. i i The adaption module is used in conjunction with measuring amplifiers and force measurement sensors without internal adaption resistors. The J-Box serves the purpose of adapting the sensors to - higher temperature ranges - potentially explosives atmospheres The J-Box contains the resistors required for the zero adjustment and nominal rating. The box is designed for DIN rail mounting in electrical cabinets. V1: Output voltage of strain gauge full bridge V4: Supply voltage for the strain gauge full bridge of the sensors Ordering Example: J-Box Vi-Vi + v4-V4+ HAEHNE Elektronische Messgerate GmbH ■ Heinrich-Hertz-Str.29 ■ D-40699 Erkrath Germany ■ Telefon 0211/9 2591-0 ■ Fax 0211/92591-20 http://www.haehne.de Email: [email protected]

 Open the catalog to page 1
Adjustmentbox J-Box-2

The calibration resistors in the J-Box are specified for the corresponding sensor only and can only be connected to this sensor. Therefore, the sensor and the J-Box carry the identical measurement location designation. For example sensor 04711-5 must be connected to the J-Box 04711-5. Wiring „higher temperature range“ HAEHNE Amplifier Hazardous area Regular area Wiring „Explosion proof“ with HAEHNE amplifier DMA, MAC and AME Safety barrier modules Hazardous area Potential equalisation cable Regular area Wiring „Explosion proof“ with HAEHNE amplifier Busbox-PS 2 Safety barrier modules HAEHNE Amplifier...

 Open the catalog to page 2

All HAEHNE catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.