SH-H, SH-Q, SH-R
2Pages

{{requestButtons}}

Catalog excerpts

SH-H, SH-Q, SH-R - 1

SH-H, SH-Q, SH-R Shunts Impulse Current Measuring Shunt Sets These shunts are used for the measurement of impulse currents in high-voltage test labs. The wave shape of the measured current can be displayed on a Haefely digital impulse analysing system e.g. DiAS733, HiAS743 or DMI 551. Design The shunts consist of a metal cylinder with coupling flanges and coaxial measuring connector. Three different construction types are available depending on the current value to be measured. Set of Sleeve Shunts SH H Interchangeable low-inductive resistor-sleeves can be built into the metal cylinder. A set consists of one cage and three sleeves of 2, 5 and 10 Ω. The standard repetition rate allows measuring impulse currents up to 250 A (voltage drop 500 V), and at reduced repetition rate up to 500 A are possible (voltage drop 1000 V). Set of Cage Shunts SH Q Each resistance value is a separate shunt. A set of cage shunts consists of three shunts of 1, 0.47 and 0.1 Ω. The standard repetition rate allows measuring impulse currents up to 5000 A (voltage drop 500 V), and at reduced repetition rate up to 16000 A are possible (voltage drop 1600 V). Set of Tubular Shunts SH R Each resistance value is a separate shunt. The standard repetition rate allows measuring impulse currents up to 100 kA (voltage drop 500 V), and at reduced repetition rate up to 200 kA are possible (voltage drop 1000 V). Tubular shunt SH R (top), Cage shunt (left) and Sleeve shunt SH H (right) a brand of Haefely is a subsidiary of Hubbell Incorporated. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice.

Open the catalog to page 1
SH-H, SH-Q, SH-R - 2

Technical Data Rated voltage drop Un Max. voltage drop Umax Rated peak current In Max. peak current Imax Resistance Accuracy Repetition rate at Umax / Imax Partial response time Tα Weight / shunt Dimensions Accuracy on the resistance measurement Accuracy at 8/20 µs impulse currents Accessories & Options Scope of supply SH H 1 Housing for the sleeves 3 Sleeves (2, 5, 10 ) 1 Coaxial measuring cable LEMO 20 m, 75 1 Termination resistor (LEMO) 75 2 Test reports (routine test: resistance measurement) KOMP BOX Compensation circuit to shunts SH Q type Scope of supply SH Q 3 Shunts (0.1, 0.47, 1 Ω)...

Open the catalog to page 2

All Haefely AG catalogs and technical brochures

  1. DDX 9160/9161

    11 Pages

  2. VITAS 2772

    4 Pages

  3. CITAS 2771

    4 Pages

  4. AXOS

    7 Pages

  5. PGR

    4 Pages

  6. CTTS Series

    8 Pages

  7. KIT 4.0

    10 Pages

  8. PSURGE 30.2

    4 Pages

  9. MAG 1000

    8 Pages

  10. TTR 2796

    5 Pages

  11. PCI 811c

    4 Pages

  12. ACS

    7 Pages

  13. 2903

    4 Pages

  14. 3695

    3 Pages

  15. 2767

    4 Pages

  16. DEC 5

    2 Pages

  17. 5478

    2 Pages

  18. 5289

    1 Pages

  19. 5288A

    1 Pages

  20. 5250

    2 Pages

  21. 3320 2 kV

    2 Pages

  22. 2840

    4 Pages

  23. 2830/2831

    4 Pages

  24. 2820a

    4 Pages

  25. 260 DC

    2 Pages

  26. 2293

    4 Pages

  27. 2226a

    2 Pages

  28. TSS

    20 Pages

  29. CTT & WPU

    8 Pages

  30. SSGA 100-150

    24 Pages

  31. USG 40

    2 Pages

  32. RM 430

    2 Pages

  33. PSK

    20 Pages

  34. RIC 422

    4 Pages

  35. RSG 482

    3 Pages

  36. DMI 551

    2 Pages

  37. DiAS® 733

    6 Pages

  38. HiAS® 743

    7 Pages

  39. KFS

    2 Pages

  40. MAFS

    2 Pages

  41. GC 257

    6 Pages

  42. GC 223

    4 Pages

  43. DTTS

    8 Pages

  44. RSKF

    4 Pages

  45. AXOS 8

    20 Pages