MFS 100 Power Frequency and Pulse Magnetic Field Test System The MFS 100 test system can be used to test power frequency magnetic fields according to IEC/EN 610004-8* and pulse magnetic field according to IEC/EN 61000-4-9**. FEATURES Up to 1200A/m field strength for pulse magnetic field. Up to 100A/m field strength for frequency magnetic field. The MFS 100 is an accessory to AXOS 5, AXOS 8 or PSURGE 8000 with PIM 100 surge generators. It enables magnetic field testing up to 1200 A/m. Standard Coil designed for major application as defined in the IEC document. Sturdy construction. MFS 100 has a 1m x 1m square, single turn antenna. A current of 1150A is needed to feed the coil to produce a field of 1000A/m. Horizontal and vertical testing possible. Supplied to ISO 9001. Magnetic field strength is defined at the center of a coil with ±3dB variation. BENEFITS Magnetic field is orthogonal to the coil plane. Coil dimensions define the maximum EUT size as being 0.6m x 0.6m x 0.5m. The MFS100 can be used for both vertical and horizontal plane testing, by simply rotating the coil antenna in its mounting on the stand. The MFS100 is designed for EUTs up to 0.5m high. To test larger EUTs, the antenna coil can be adjusted in height on the mounting stand. Compact Design - to fulfill both the IEC/EN 610004-8* and IEC 61000 4-9** standards Single Turn Coil Only One Support Stand - is needed for all magnetic field tests in accordance with IEC 61000-4-8*/9** The MFS100 construction makes it easy to adjust the antenna height. The MFS 100 antenna can also be rotated through 90° and placed alongside large EUTs to test all four faces of the test object. MFS 100 1mx1m antenna mounted on support stand (above) shown with the MFS 100 control unit Designed by H I G H V O LTA G E TEST SOLUTIONS
Open the catalog to page 1TECHNICAL SPECIFICATIONS 230V 50/60Hz 460VA 0 to 16A at “MIN” Range 0 to 124A at “MAX” Range 0 to 14A/m at “MIN” Range 0 to 108 A/m at “Max” Range 0 to 1200A 50/60Hz Coil Current 50/60Hz Magnetic Field Coil Factor 8/20us Magnetic Field duration *Test levels for short duration: 1 s to 3 s are not being supported **An external Surge Combination Wave generator is being required OFFICES: Europe Haefely Test AG Birsstrasse 300 4052 Basel Switzerland + 41 61 373 4111 + 41 61 373 4912 sales@haefely.com China Haefely Test AG Representative Beijing Office 8-1-602, Fortune Street No. 67, Chaoyang...
Open the catalog to page 2All Haefely AG catalogs and technical brochures
-
DDX 9160/9161
11 Pages
-
VITAS 2772
4 Pages
-
CITAS 2771
4 Pages
-
2763 / 2767 / 2769
6 Pages
-
AXOS
7 Pages
-
PGR
4 Pages
-
CTTS Series
8 Pages
-
KIT 4.0
10 Pages
-
PSURGE 30.2
4 Pages
-
MAG 1000
8 Pages
-
MIDAS micro 2883
6 Pages
-
TTR 2796
5 Pages
-
PCI 811c
4 Pages
-
ACS
7 Pages
-
2903
4 Pages
-
3695
3 Pages
-
NK SERIES, 3370
4 Pages
-
2767
4 Pages
-
High Voltage Construction KIT
28 Pages
-
UHVDC - Applied DC Testing
4 Pages
-
DEC 5
2 Pages
-
5478
2 Pages
-
5289
1 Pages
-
5288A
1 Pages
-
5250
2 Pages
-
4762 Range Extender
1 Pages
-
3320 2 kV
2 Pages
-
2914 Solid Test Cell
3 Pages
-
2903 Oil Test Cell
2 Pages
-
2840
4 Pages
-
2830/2831
4 Pages
-
2820a
4 Pages
-
260 DC
2 Pages
-
2293
4 Pages
-
2226a
2 Pages
-
TSS
20 Pages
-
CTT & WPU
8 Pages
-
SSGA 100-150
24 Pages
-
USG 40
2 Pages
-
RM 430
2 Pages
-
PSK
20 Pages
-
R 500 REF, RCZ 500 REF
2 Pages
-
RIC 422
4 Pages
-
RSG 482
3 Pages
-
DMI 551
2 Pages
-
DiAS® 733
6 Pages
-
HiAS® 743
7 Pages
-
KFS
2 Pages
-
MAFS
2 Pages
-
GC 257
6 Pages
-
GC 223
4 Pages
-
SH-H, SH-Q, SH-R
2 Pages
-
DTTS
8 Pages
-
Global Services
8 Pages
-
RSKF
4 Pages
-
Partial Discharge
24 Pages
-
Portable Instruments
13 Pages
-
Product Overview Tettex
20 Pages
-
ONYX ESD simulator
8 Pages
-
Product Overview 2013
24 Pages
-
AXOS 8
20 Pages