DiAS® 733
6Pages

{{requestButtons}}

Catalog excerpts

DiAS® 733 - 1

DiAS® 733 Digital Impulse Analyzing System The DiAS®733 is ready for integration in a complete impulse voltage test system. The system can be fully controlled by a host computer via standard interfaces or, to reduce interference effect, via an optical link. Capturing the complete impulse enables to obtain information about the test object faster and in more detail. DiAS®733 is the tool which utilizes latest technology to perform this task. The DiAS®733 is a compact 1- or 2-channel digital impulse analyzing system. Measurement evaluation and analysis of impulse voltages and currents can be performed according to IEC 61083, IEC 60060, IEC 60076, IEC 60099, and IEC 60230, the relevant standards for High Voltage Impulse Testing. Automatic evaluation of the impulse shapes specified in the above standards, as well as a manual evaluation mode are available. Automatic evaluation of all common impulse shapes and their parameters DiAS®733 incorporates many of our own experiences in the high voltage business, plus those of our customers. 128 k memory point depth (for 10 bit data) Impulse voltage tests in industry are mainly used to control the quality of any high voltage equipment. Usually the test object is subjected to a fast voltage impulse. A defined impulse wave shape is applied to the test object according to the relevant standards. Changes in the waveshape caused by the test object are used for detection of insulation faults. This procedure is commonly used for routine testing of transformers, bushings or other high voltage equipment. The DiAS®733 is an excellent and reliable tool for accurate measurement of all kinds of waveshapes. Haefely Test AG also manufacture complete impulse voltage test systems to meet most requirements. This impulse generation capability plus impulse measurement offers a complete solution to modern testing needs. 10 bit real vertical resolution at 100 MS/s Loaded with functionalities: Difference, Parameter Tolerance, FFT, Step response, Smoothing, Advanced Evaluation and more Clear documentation and reporting including, Test information, notes, grouping, etc. BENEFITS Easy, intuitive understandable and useable graphic user interface (GUI) Automatic test report generation from the integrated reporting tool with user definable layout, logo insertion, etc. Manual re-evaluation tool for all impulse parameters. Automatic hardware calibration with additional calibrator RIC422-4 Easy re-calibration and system upgrade due to modular and independent hardware design. APPLICATIONS testing of: Distribution Transformers Power Transformers Switchgears Surge Arrestors Cables Research & Development Universities etc. a brand of Haefely is a subsidiary of Hubbell Incorporated. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice.

Open the catalog to page 1
DiAS® 733 - 2

HIGH VOLTAGE TEST MEASUREMENT (DIGITIZING) FEATURES ANALIZING FEATURES 10 bit amplitude resolution. Together with the powerful software analysis tools detailed impulse Variable memory depth up to 128k data points. memory depth allows to choose a suitable record length and helps to avoid unnecessarily large file 100 MS/s and an analogue bandwidth of 30 MHz is fast enough to capture the common impulse shapes in high voltage test labs. High frequency signal components usually have very low amplitudes. High amplitude resolution is therefore critical. The highest bandwidth limit is usually...

Open the catalog to page 2
DiAS® 733 - 3

HIGH VOLTAGE TEST Difference Function to subtract two wave-shapes. With auto-fitting and auto-zooming. Chose your curves from the database or define automated calculation sequences with pass/fail output. ^^^^^^ ^^^^^^^^ Iriseil | | Full lightning impulse 24 07 97 16 f6 2S T] Parameter Tolerance Analysis to enter a max. limit on evaluated parameters (e.g. Upk ± 5 %). Define sequences with pass/fail output. Actual reference and range of tolerance for passino : Parameter Reference value Range of tolerance Sequence Function (option) enables full test sequences to be automated for applications...

Open the catalog to page 3
DiAS® 733 - 4

HIGH VOLTAGE TEST All standard Windows features are included. Self explanatory menus and symbols, quick access ft Settjrig FA E) Option F5 [?) Help F1 on-line help and hint graphically supported dialogue boxes. E.g. select "Shunt" and enter a terminal value of 330 A/V. A measuring circuit image, the chosen input range and the correct input connector are indicated as well as the hint to use a matching resistor. Test wild Terminal value <~ DMIJSI r^ShuH (T) Inpul range @ 1 DO % Office software (option) for training or analysis. An identical software, that hardware, enables off-line help for...

Open the catalog to page 4
DiAS® 733 - 5

TECHNICAL SPECIFICATIONS System Number of channels Printer Monitor System controller (build-in) Internal operating system 1...2 Inkjet color printer Desktop screen 17" PentiumIII, 256 MB RAM Windows XP (also Windows 98, 2000 for “Office software”) Analogue Part Connections Input divider Input voltages Input ranges Overvoltage protection Overvoltage tested Input impedance Analogue bandwidth (-3dB) Triggering High voltage input LEMO (RA4250) 1 : 200 100 Vpp .. 1950 Vpp 14 (factor 1.26) 2 kV 6 kVpp (1.2/50 s, 10/700 s) 2 MOhm // 20 pF 30 MHz internal on slope or level external on slope and...

Open the catalog to page 5
DiAS® 733 - 6

SYSTEM DESIGN ORDERING INFORMATION DiAS 733System consists of a main unit, containing the system CPU, control computer, power supplies, data storage, interfaces and 2 slots for the exchangeable measuring channel inserts. All accuracy sensitive elements are combined in one small unit per channel. Also supplied are peripheral devices printer, monitor, keyboard and mouse. The advantage of this modular design is that a single measuring channel insert (digitizer) can be easy pulled out and send back for re-calibration while the system works with the other channels. So there is no down time on...

Open the catalog to page 6

All Haefely AG catalogs and technical brochures

  1. DDX 9160/9161

    11 Pages

  2. VITAS 2772

    4 Pages

  3. CITAS 2771

    4 Pages

  4. AXOS

    7 Pages

  5. PGR

    4 Pages

  6. CTTS Series

    8 Pages

  7. KIT 4.0

    10 Pages

  8. PSURGE 30.2

    4 Pages

  9. MAG 1000

    8 Pages

  10. TTR 2796

    5 Pages

  11. PCI 811c

    4 Pages

  12. ACS

    7 Pages

  13. 2903

    4 Pages

  14. 3695

    3 Pages

  15. 2767

    4 Pages

  16. DEC 5

    2 Pages

  17. 5478

    2 Pages

  18. 5289

    1 Pages

  19. 5288A

    1 Pages

  20. 5250

    2 Pages

  21. 3320 2 kV

    2 Pages

  22. 2840

    4 Pages

  23. 2830/2831

    4 Pages

  24. 2820a

    4 Pages

  25. 260 DC

    2 Pages

  26. 2293

    4 Pages

  27. 2226a

    2 Pages

  28. TSS

    20 Pages

  29. CTT & WPU

    8 Pages

  30. SSGA 100-150

    24 Pages

  31. USG 40

    2 Pages

  32. RM 430

    2 Pages

  33. PSK

    20 Pages

  34. RIC 422

    4 Pages

  35. RSG 482

    3 Pages

  36. DMI 551

    2 Pages

  37. HiAS® 743

    7 Pages

  38. KFS

    2 Pages

  39. MAFS

    2 Pages

  40. GC 257

    6 Pages

  41. GC 223

    4 Pages

  42. DTTS

    8 Pages

  43. RSKF

    4 Pages

  44. AXOS 8

    20 Pages