Catalog excerpts
33kVA, lOkV Mobile Resonating Inductor for use with MIDAS System The capacitive load range of the MIDAS system can be increased by using this Compensating Reactor (resonating inductor). The 5288A provide a manual tuneable lOkV, 33kVA inductor coil. It comes into use mainly for power generator or other high capacitive loads on-site testing. The variable inductor is connected in parallel with the capacitive test object Cx. This configuration constitutes a parallel resonant By adjusting the inductor LK the resonant point In this resonant configuration the inductor compensates the reactive power required by the capacitor and only a smaller proportion of real power (ohmic losses) is taken from the main This arrangement enables measurement of capacitances up to l|iF at lOkV. Technical Specifications Maximum Output Current Maximum Output Power Inductance range (typical) 9.7H .. 250H Load tuning range Duty cycle at full load power over a 16h period. Dimensions WxDxH Operating Temperature Storage Temperature Relative Humidity 5288A resonating inductor including cable set (3m) for complete installation together with MIDAS system. European Contact Locate your local sales representative at High Voltage Test Business HAEFELY^ HIPOTRONICS |f|ROBINSON HIGH VOLTAGE TEST Subject to change without notice.
Open the catalog to page 1All Haefely AG catalogs and technical brochures
-
DDX 9160/9161
11 Pages
-
VITAS 2772
4 Pages
-
CITAS 2771
4 Pages
-
2763 / 2767 / 2769
6 Pages
-
AXOS
7 Pages
-
PGR
4 Pages
-
CTTS Series
8 Pages
-
KIT 4.0
10 Pages
-
PSURGE 30.2
4 Pages
-
MAG 1000
8 Pages
-
MIDAS micro 2883
6 Pages
-
TTR 2796
5 Pages
-
PCI 811c
4 Pages
-
ACS
7 Pages
-
2903
4 Pages
-
3695
3 Pages
-
NK SERIES, 3370
4 Pages
-
2767
4 Pages
-
High Voltage Construction KIT
28 Pages
-
UHVDC - Applied DC Testing
4 Pages
-
DEC 5
2 Pages
-
5478
2 Pages
-
5289
1 Pages
-
5250
2 Pages
-
4762 Range Extender
1 Pages
-
3320 2 kV
2 Pages
-
2914 Solid Test Cell
3 Pages
-
2903 Oil Test Cell
2 Pages
-
2840
4 Pages
-
2830/2831
4 Pages
-
2820a
4 Pages
-
260 DC
2 Pages
-
2293
4 Pages
-
2226a
2 Pages
-
TSS
20 Pages
-
CTT & WPU
8 Pages
-
SSGA 100-150
24 Pages
-
USG 40
2 Pages
-
RM 430
2 Pages
-
PSK
20 Pages
-
R 500 REF, RCZ 500 REF
2 Pages
-
RIC 422
4 Pages
-
RSG 482
3 Pages
-
DMI 551
2 Pages
-
DiAS® 733
6 Pages
-
HiAS® 743
7 Pages
-
KFS
2 Pages
-
MAFS
2 Pages
-
GC 257
6 Pages
-
GC 223
4 Pages
-
SH-H, SH-Q, SH-R
2 Pages
-
DTTS
8 Pages
-
Global Services
8 Pages
-
RSKF
4 Pages
-
Partial Discharge
24 Pages
-
Portable Instruments
13 Pages
-
Product Overview Tettex
20 Pages
-
ONYX ESD simulator
8 Pages
-
Product Overview 2013
24 Pages
-
AXOS 8
20 Pages