4860 Electronic Divider System
4Pages

{{requestButtons}}

Catalog excerpts

4860 Electronic Divider System - 1

4860 Standard Electronic Voltage Dividers The 4860 series (control unit and capacitive HV divider with compressed gas and air capacitors) high precision standard voltage divider is used as a variable comparison standard in the differential method (bridge) measurement of high voltage instrument transformers. The special active guard controlled design of this divider set results in highest accuracy. This standard voltage divider is ideal for integration with the 2767 or 2769 test set in a full remote controlled instrument voltage transformer test system Universal comparison standard for any transformer ratios within a wide voltage range Very accurate voltage divider ratio (± 50 ppm, ± 0.1 min) Max. measurement voltage is dependent only on rated voltage of compressed gas capacitor For voltages less than 1000 V the electronic device can be used without additional divider VOLTAGE DIVIDER ARRANGEMENT HIGH VOLTAGE DIVIDER UNIT The high voltage divider unit comprises a capacitive high voltage divider (compressed gas standard capacitor C1 and air capacitor C2) and an electronic device in series, constituting a variable electronic divider (see system diagram). Capacitive voltage divider C1/C2 divides the primary voltage Uprim to voltage U1, which the electronic device matches to the required secondary voltage Usec. Voltage instrument transformers of less than 1 kV primary voltage can be connected directly to the electronic system via the adaptor box supplied with the divider. Easy handling Suitable for all Tettex (2767, 2765, 2711/22 and 2711/23) and many other manufacturers’ transformer test sets Direct replacement of earlier series 4850 Existing compressed gas capacitors can generally be equipped to form a complete system. Complete system is certifiable Remote control possibility via IEEE 488 or RS 232C interface ELECTRONIC DEVICE The main components of this system are an input amplifier and a guard-potential control (up to 1010 V), an electronic divider and a power amplifier with the output stage. The instrument is protected against setting errors, overvoltages and short-circuits. Errors message are indicated on the dot matrix display. to an automatic combination with a type 2767 A more cost-effective solution than inductive voltage standard transformers, especially for high rated voltage systems.

Open the catalog to page 1
4860 Electronic Divider System - 2

BASIC TEST SET-UP Measurement circuit with capacitive divider for > 1 kV primary voltage Legend for abbreviations used PV Primary rated voltage SV Secondary rated voltage CR Capacitive divider ratio (C-Ratio) Uprim Primary voltage Usec Secondary voltage U1 Electronic divider input voltage U Test voltage (primary or secondary) UR Rated voltage (primary or secondary) U/UR Excitation ELECTRONIC STANDARD VOLTAGE DIVIDER SERIES 4860 STANDARD SYSTEMS C1 Type (gas) [Serie/pF/kV] Measurement range (Uprim) * range covered by any other type e.g. 4861/300

Open the catalog to page 2
4860 Electronic Divider System - 3

TYPE 4861 STANDARD VERSION GENERAL DATA This version has up to two fixed voltage divider ratios set by HAEFELY HIPOTRONICS, which the user cannot change. The complete standard voltage divider is therefore certifiable. Power supply TYPE 4862 CUSTOMIZED VERSION The user can set two ratios and change them whenever needed. This standard divider is not certifiable. Power requirement Storage and transport temperature ERROR LIMITS TECHNICAL SPECIFICATIONS Intrinsic error (electronic device) ELECTRONIC SYSTEM TYPES 4861 Input Max. input voltage U1 Test frequency Input resistance Input capacitance...

Open the catalog to page 3
4860 Electronic Divider System - 4

ORDER SPECIFICATION STANDARD SUPPLY Standard voltage divider as per standard system type series 4860, comprising: Electronic device - RS 232C interface (fibre optic data-link) Adaptor box for direct connection, Triax/coax adapter for compressed gas capacitor (for C/tan δ measurement) Measuring cable, 10 m Measuring cable, 1.5 m Replacement of series 4850 electronic device by type 4861 The connections are compatible with the existing unit. Determine and set the capacity divider ratio. Power cable Power voltage (please specify with order) Including RS 232C interface Adaption and commissioning...

Open the catalog to page 4

All Haefely AG catalogs and technical brochures

  1. DDX 9160/9161

    11 Pages

  2. VITAS 2772

    4 Pages

  3. CITAS 2771

    4 Pages

  4. AXOS

    7 Pages

  5. PGR

    4 Pages

  6. CTTS Series

    8 Pages

  7. KIT 4.0

    10 Pages

  8. PSURGE 30.2

    4 Pages

  9. MAG 1000

    8 Pages

  10. TTR 2796

    5 Pages

  11. PCI 811c

    4 Pages

  12. ACS

    7 Pages

  13. 2903

    4 Pages

  14. 3695

    3 Pages

  15. 2767

    4 Pages

  16. DEC 5

    2 Pages

  17. 5478

    2 Pages

  18. 5289

    1 Pages

  19. 5288A

    1 Pages

  20. 5250

    2 Pages

  21. 3320 2 kV

    2 Pages

  22. 2840

    4 Pages

  23. 2830/2831

    4 Pages

  24. 2820a

    4 Pages

  25. 260 DC

    2 Pages

  26. 2293

    4 Pages

  27. 2226a

    2 Pages

  28. TSS

    20 Pages

  29. CTT & WPU

    8 Pages

  30. SSGA 100-150

    24 Pages

  31. USG 40

    2 Pages

  32. RM 430

    2 Pages

  33. PSK

    20 Pages

  34. RIC 422

    4 Pages

  35. RSG 482

    3 Pages

  36. DMI 551

    2 Pages

  37. DiAS® 733

    6 Pages

  38. HiAS® 743

    7 Pages

  39. KFS

    2 Pages

  40. MAFS

    2 Pages

  41. GC 257

    6 Pages

  42. GC 223

    4 Pages

  43. DTTS

    8 Pages

  44. RSKF

    4 Pages

  45. AXOS 8

    20 Pages