Catalog excerpts
2903 Test Cell Liquid Insultants The precision test cell type 2903 measures the dielectric properties of liquid insulants such as insulating oil, i.e. it determines the dissipation factor tan and the dielectric constant r as well as the specific resistivity. DESIGN The complete test cell type 2903 consists of the actual test cell type 2903a as well as a pot with built-in heating. The test cell has been designed as a cylindrical capacitor with a shielded measuring electrode (guard ring capacitor) thus avoiding partial capacitances, which might influence the test results. The test cell consists of a cylindrical container (highvoltage electrode) with a shielded measuring electrode inside. The cell is vacuum-sealed by a locking head. It further includes a socket for the measuring electrode, two vacuum connections, and a stern thermometer. The test cell's design is in accordance with the specifications of VDE 0303, 0370 (Fed. Republic of Germany), SEV (Switzerland) and the recommendations of CIGRE. IEC and ISO, as well as with ASTM standards (USA). To conduct measurements the test cell is inserted into the pot. The sockets far high voltage, the temperature controller and the temperature measuring bridge are mounted on the pot's top panel made of insulation material. The temperature controller type 2967 with digital temperature adjustment is used to heat up the test cell. Always check suitability of the equipment for the considered test cells. It should also be noted that the power supply used must have a low short-circuit power characteristic (e.g. a resonant power supply). ADVANTAGES & BENEFITS The test cell is in accordance with international standards and specifications. The test cell is heatable. The temperature is adjustable up to 150°C The cell can be evacuated, e.g. to degas the insulating oil. The electrodes are made of stainless steel. The test results are reproducible thanks to precise mechanical design. To degas the measured liquid (e.g. oil) we recommend our vacuum pump type 2973. FEATURES No-load capacitance ≈ 60 pF Electrode spacing 2 mm Amount of liquid 40 cm3 Electrode material stainless steel Surface micro finished Electrode ambient temperature .. 150°C temperature Heating capacity heating jacket 300 W,. heating cartridge 150 W, total 450W Heat-up time 60 min. Built-in fuses 4A Max. test voltage 2000 V RMS, 50/60 Hz Max. electric field 10 kV/cm Dimensions 0 95x175 mm (3.8x6.9 ins) Test cell type 2903a 0 240x220 mm (9.5x8.7 ins) Test cell 2903a with heating pot 2903 Weight 5.2 kg (11.5 lbs) Test cell type 2903a 8.2 kg (18 lbs) Test cell with heating type 2903
Open the catalog to page 1TECHNICAL SPECIFICATIONS Heated test cell for liquid insulation type 2903 Heating voltage: 230 V or 115 V 50/60 Hz (need 2967: Temperature controller, control range up to 300°C 2973: Vacuum pump equipment only be quoted when temperature controller type 2967 is used) Tools and spares Vacuum pump hose coupling Two connecting cables to measuring bridge and power supply OFFICES: Europe Haefely Test AG Birsstrasse 300 4052 Basel Switzerland + 41 61 373 4111 + 41 61 373 4912 sales@haefely.com China Haefely Test AG Representative Beijing Office 8-1-602, Fortune Street No. 67, Chaoyang Road,...
Open the catalog to page 2All Haefely AG catalogs and technical brochures
-
DDX 9160/9161
11 Pages
-
VITAS 2772
4 Pages
-
CITAS 2771
4 Pages
-
2763 / 2767 / 2769
6 Pages
-
AXOS
7 Pages
-
PGR
4 Pages
-
CTTS Series
8 Pages
-
KIT 4.0
10 Pages
-
PSURGE 30.2
4 Pages
-
MAG 1000
8 Pages
-
MIDAS micro 2883
6 Pages
-
TTR 2796
5 Pages
-
PCI 811c
4 Pages
-
ACS
7 Pages
-
2903
4 Pages
-
3695
3 Pages
-
NK SERIES, 3370
4 Pages
-
2767
4 Pages
-
High Voltage Construction KIT
28 Pages
-
UHVDC - Applied DC Testing
4 Pages
-
DEC 5
2 Pages
-
5478
2 Pages
-
5289
1 Pages
-
5288A
1 Pages
-
5250
2 Pages
-
4762 Range Extender
1 Pages
-
3320 2 kV
2 Pages
-
2914 Solid Test Cell
3 Pages
-
2840
4 Pages
-
2830/2831
4 Pages
-
2820a
4 Pages
-
260 DC
2 Pages
-
2293
4 Pages
-
2226a
2 Pages
-
TSS
20 Pages
-
CTT & WPU
8 Pages
-
SSGA 100-150
24 Pages
-
USG 40
2 Pages
-
RM 430
2 Pages
-
PSK
20 Pages
-
R 500 REF, RCZ 500 REF
2 Pages
-
RIC 422
4 Pages
-
RSG 482
3 Pages
-
DMI 551
2 Pages
-
DiAS® 733
6 Pages
-
HiAS® 743
7 Pages
-
KFS
2 Pages
-
MAFS
2 Pages
-
GC 257
6 Pages
-
GC 223
4 Pages
-
SH-H, SH-Q, SH-R
2 Pages
-
DTTS
8 Pages
-
Global Services
8 Pages
-
RSKF
4 Pages
-
Partial Discharge
24 Pages
-
Portable Instruments
13 Pages
-
Product Overview Tettex
20 Pages
-
ONYX ESD simulator
8 Pages
-
Product Overview 2013
24 Pages
-
AXOS 8
20 Pages